MIB Viewer

OMNI-gx2RSW200-MIB

110 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.8.1Nodegx2Rsw200Descriptor
1.3.6.1.4.1.1166.6.1.2.8.1NodetrapRSW200ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.8.2Tablegx2Rsw200AnalogTablenot-accessiblemandatoryThis table contains gx2Rsw200 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.8.2NodetrapRSW200ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.8.2.1Rowgx2Rsw200AnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.8.2.1.1Columngx2Rsw200AnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.8.2.1.2Columnrsw200labelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.8.2.1.3Columnrsw200uomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.8.2.1.4Columnrsw200majorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.8.2.1.5Columnrsw200majorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.8.2.1.6Columnrsw200minorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.8.2.1.7Columnrsw200minorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.8.2.1.8Columnrsw200currentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.8.2.1.9Columnrsw200stateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.2.1.10Columnrsw200minValueModTempread-onlymandatoryThe value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.8.2.1.11Columnrsw200maxValueModTempread-onlymandatoryThe value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.8.2.1.12Columnrsw200alarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.8.2.1.13Columnrsw200labelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.8.2.1.14Columnrsw200uomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.8.2.1.15Columnrsw200majorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.8.2.1.16Columnrsw200majorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.8.2.1.17Columnrsw200minorHighFanCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.8.2.1.18Columnrsw200minorLowFanCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.8.2.1.19Columnrsw200currentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.8.2.1.20Columnrsw200stateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.2.1.21Columnrsw200minValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.8.2.1.22Columnrsw200maxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.8.2.1.23Columnrsw200alarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.8.3Tablegx2Rsw200DigitalTablenot-accessiblemandatoryThis table contains gx2Rsw200 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.8.3NodetrapRSW200RFInputAlarmThis trap is issued when the Switch Control signals go out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2Rowgx2Rsw200DigitalEntrynot-accessiblemandatoryThis list contains digital parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.8.3.2.1Columngx2Rsw200DigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.8.3.2.2Columnrsw200labelSwitchControlread-onlyoptionalThe value of this object provides the label of the Switch Control Digital parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.3Columnrsw200enumSwitchControlread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.8.3.2.4Columnrsw200valueSwitchControlread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.5Columnrsw200stateflagSwitchControlread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.3.2.6Columnrsw200labelRevertModeread-onlyoptionalThe value of this object provides the label of the Revert Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.7Columnrsw200enumRevertModeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.8.3.2.8Columnrsw200valueRevertModeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.9Columnrsw200stateflagRevertModeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.3.2.10Columnrsw200labelRevertTimeread-onlyoptionalThe value of this object provides the label of the Revert Time Digital parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.11Columnrsw200enumRevertTimeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.8.3.2.12Columnrsw200valueRevertTimeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.13Columnrsw200stateflagRevertTimeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.3.2.14Columnrsw200labelSwitchStateread-onlyoptionalThe value of this object provides the label of the Switch State Digital parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.15Columnrsw200enumSwitchStateread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.8.3.2.16Columnrsw200valueSwitchStateread-onlymandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.17Columnrsw200stateflagSwitchStateread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.3.2.18Columnrsw200labelPriStatusread-onlyoptionalThe value of this object provides the label of the Primary Signal Status Digital parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.19Columnrsw200enumPriStatusread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.8.3.2.20Columnrsw200valuePriStatusread-onlymandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.21Columnrsw200stateflagPriStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.3.2.22Columnrsw200labelSecStatusread-onlyoptionalThe value of this object provides the label of the Secondary Signal Status Digital parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.23Columnrsw200enumSecStatusread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.8.3.2.24Columnrsw200valueSecStatusread-onlymandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.25Columnrsw200stateflagSecStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.3.2.26Columnrsw200labelFactoryDefaultread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.27Columnrsw200enumFactoryDefaultread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.8.3.2.28Columnrsw200valueFactoryDefaultread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.8.3.2.29Columnrsw200stateflagFactoryDefaultread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.4Tablegx2Rsw200StatusTablenot-accessiblemandatoryThis table contains gx2Rsw200 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.8.4NodetrapRSW200FanCurrentAlarmThis trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.8.4.3Rowgx2Rsw200StatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.8.4.3.1Columngx2Rsw200StatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.8.4.3.2Columnrsw200labelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.8.4.3.3Columnrsw200valueBootread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.8.4.3.4Columnrsw200stateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.4.3.5Columnrsw200labelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.8.4.3.6Columnrsw200valueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.8.4.3.7Columnrsw200stateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.4.3.8Columnrsw200labelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.8.4.3.9Columnrsw200valueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.8.4.3.10Columnrsw200stateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.4.3.11Columnrsw200labelAlarmDataCrcread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.8.4.3.12Columnrsw200valueAlarmDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.8.4.3.13Columnrsw200stateflagAlarmDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.4.3.14Columnrsw200labelRFSignalStatusread-onlyoptionalThe value of this object provides the label of the RF Signal Status parameter.
1.3.6.1.4.1.1166.6.1.2.8.4.3.15Columnrsw200valueRFSignalStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.8.4.3.16Columnrsw200stateflagRFSignalStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.4.3.17Columnrsw200labelPriActiveStatusread-onlyoptionalThe value of this object provides the label of the Secondary Active Status parameter.
1.3.6.1.4.1.1166.6.1.2.8.4.3.18Columnrsw200valuePriActiveStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.8.4.3.19Columnrsw200stateflagPriActiveStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.8.5Tablegx2Rsw200FactoryTablenot-accessiblemandatoryThis table contains gx2Rsw200 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.8.5NodetrapRSW200ModuleTempAlarmThis trap is issued when the Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.8.5.4Rowgx2Rsw200FactoryEntrynot-accessiblemandatoryThis list contains Factory parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.8.5.4.1Columngx2Rsw200FactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.8.5.4.2Columnrsw200bootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.8.5.4.3Columnrsw200bootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.8.5.4.4Columnrsw200bank1CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.8.5.4.5Columnrsw200bank2CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.8.5.4.6Columnrsw200prgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.8.5.4.7Columnrsw200factoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.8.5.4.8Columnrsw200calculateCRCread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.8.5.4.9Columnrsw200hourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.8.5.4.10Columnrsw200flashPrgCntAread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.8.5.4.11Columnrsw200flashPrgCntBread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.8.5.4.12Columnrsw200flashBankARevread-onlymandatoryThis object provides the revision of flash bank 0.
1.3.6.1.4.1.1166.6.1.2.8.5.4.13Columnrsw200flashBankBRevread-onlymandatoryThis object provides the revision of flash bank 1.
1.3.6.1.4.1.1166.6.1.2.8.6Tablegx2Rsw200bHoldTimeTablenot-accessiblemandatoryThis table contains gx2Rsw200b specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.8.6NodetrapRSW200FlashAlarmThis trap is issued when the detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.8.6.5Rowgx2Rsw200bHoldTimeEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.8.6.5.1Columnrxgx2Rsw200bHoldTimeTableIndexread-onlymandatoryThe value of this object is the index of the data object.
1.3.6.1.4.1.1166.6.1.2.8.6.5.2Columnrxgx2Rsw200bHoldTimeSpecIndexread-onlymandatoryThe value of this object identifies the index of the alarm object to be modified.
1.3.6.1.4.1.1166.6.1.2.8.6.5.3Columnrxgx2Rsw200bHoldTimeDataread-writemandatoryThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered…
1.3.6.1.4.1.1166.6.1.2.8.7NodetrapRSW200BankBootAlarmThis trap is issued when the detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.8.8NodetrapRSW200AlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.8.9NodetrapRSW200FactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.8.10NodetrapRSW200InputSwitchedAlarmThis trap is issued when the RF input switched.
1.3.6.1.4.1.1166.6.1.2.8.11NodetrapRSW200ResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs.
1.3.6.1.4.1.1166.6.1.2.8.12NodetrapRSW200SecondaryInputActiveAlarmThis trap is issued when the scondary input becomes active.