OMNI-gx2RSW200-MIB
110 objects
No module-level DESCRIPTION found.
Imported Objects
| GX2HFC-MIB | gx2Rsw200 |
| NLS-BBNIDENT-MIB | -- gi motproxies -- |
| NLSBBN-TRAPS-MIB | trapChangedObjectId trapChangedValueDisplayString trapChangedValueInteger trapIdentifier trapNETrapLastTrapTimeStamp trapNetworkElemAdminState trapNetworkElemAlarmStatus trapNetworkElemAvailStatus trapNetworkElemModelNumber trapNetworkElemOperState trapNetworkElemSerialNum trapPerceivedSeverity trapText |
| RFC-1212 | -- OBJECT-TYPE -- |
| RFC-1215 | -- TRAP-TYPE -- |
| RFC1155-SMI | -- IpAddress TimeTicks -- |
| RFC1213-MIB | -- sysUpTime DisplayString -- |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.8.1 | Nodegx2Rsw200Descriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.8.1 | NodetrapRSW200ConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.8.2 | Tablegx2Rsw200AnalogTable | not-accessible | mandatory | This table contains gx2Rsw200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.8.2 | NodetrapRSW200ConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.8.2.1 | Rowgx2Rsw200AnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.1 | Columngx2Rsw200AnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.2 | Columnrsw200labelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.3 | Columnrsw200uomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.4 | Columnrsw200majorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.5 | Columnrsw200majorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.6 | Columnrsw200minorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.7 | Columnrsw200minorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.8 | Columnrsw200currentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.9 | Columnrsw200stateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.10 | Columnrsw200minValueModTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.11 | Columnrsw200maxValueModTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.12 | Columnrsw200alarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.13 | Columnrsw200labelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.14 | Columnrsw200uomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.15 | Columnrsw200majorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.16 | Columnrsw200majorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.17 | Columnrsw200minorHighFanCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.18 | Columnrsw200minorLowFanCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.19 | Columnrsw200currentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.20 | Columnrsw200stateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.21 | Columnrsw200minValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.22 | Columnrsw200maxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.8.2.1.23 | Columnrsw200alarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3 | Tablegx2Rsw200DigitalTable | not-accessible | mandatory | This table contains gx2Rsw200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.8.3 | NodetrapRSW200RFInputAlarm | This trap is issued when the Switch Control signals go out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.8.3.2 | Rowgx2Rsw200DigitalEntry | not-accessible | mandatory | This list contains digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.1 | Columngx2Rsw200DigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.2 | Columnrsw200labelSwitchControl | read-only | optional | The value of this object provides the label of the Switch Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.3 | Columnrsw200enumSwitchControl | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.4 | Columnrsw200valueSwitchControl | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.5 | Columnrsw200stateflagSwitchControl | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.6 | Columnrsw200labelRevertMode | read-only | optional | The value of this object provides the label of the Revert Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.7 | Columnrsw200enumRevertMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.8 | Columnrsw200valueRevertMode | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.9 | Columnrsw200stateflagRevertMode | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.10 | Columnrsw200labelRevertTime | read-only | optional | The value of this object provides the label of the Revert Time Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.11 | Columnrsw200enumRevertTime | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.12 | Columnrsw200valueRevertTime | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.13 | Columnrsw200stateflagRevertTime | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.14 | Columnrsw200labelSwitchState | read-only | optional | The value of this object provides the label of the Switch State Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.15 | Columnrsw200enumSwitchState | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.16 | Columnrsw200valueSwitchState | read-only | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.17 | Columnrsw200stateflagSwitchState | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.18 | Columnrsw200labelPriStatus | read-only | optional | The value of this object provides the label of the Primary Signal Status Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.19 | Columnrsw200enumPriStatus | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.20 | Columnrsw200valuePriStatus | read-only | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.21 | Columnrsw200stateflagPriStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.22 | Columnrsw200labelSecStatus | read-only | optional | The value of this object provides the label of the Secondary Signal Status Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.23 | Columnrsw200enumSecStatus | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.24 | Columnrsw200valueSecStatus | read-only | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.25 | Columnrsw200stateflagSecStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.26 | Columnrsw200labelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.27 | Columnrsw200enumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.28 | Columnrsw200valueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.3.2.29 | Columnrsw200stateflagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.4 | Tablegx2Rsw200StatusTable | not-accessible | mandatory | This table contains gx2Rsw200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.8.4 | NodetrapRSW200FanCurrentAlarm | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.8.4.3 | Rowgx2Rsw200StatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.1 | Columngx2Rsw200StatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.2 | Columnrsw200labelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.3 | Columnrsw200valueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.4 | Columnrsw200stateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.5 | Columnrsw200labelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.6 | Columnrsw200valueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.7 | Columnrsw200stateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.8 | Columnrsw200labelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.9 | Columnrsw200valueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.10 | Columnrsw200stateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.11 | Columnrsw200labelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.12 | Columnrsw200valueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.13 | Columnrsw200stateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.14 | Columnrsw200labelRFSignalStatus | read-only | optional | The value of this object provides the label of the RF Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.15 | Columnrsw200valueRFSignalStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.16 | Columnrsw200stateflagRFSignalStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.17 | Columnrsw200labelPriActiveStatus | read-only | optional | The value of this object provides the label of the Secondary Active Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.18 | Columnrsw200valuePriActiveStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.8.4.3.19 | Columnrsw200stateflagPriActiveStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.8.5 | Tablegx2Rsw200FactoryTable | not-accessible | mandatory | This table contains gx2Rsw200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.8.5 | NodetrapRSW200ModuleTempAlarm | This trap is issued when the Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.8.5.4 | Rowgx2Rsw200FactoryEntry | not-accessible | mandatory | This list contains Factory parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.1 | Columngx2Rsw200FactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.2 | Columnrsw200bootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.3 | Columnrsw200bootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.4 | Columnrsw200bank1CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.5 | Columnrsw200bank2CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.6 | Columnrsw200prgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.7 | Columnrsw200factoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.8 | Columnrsw200calculateCRC | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.9 | Columnrsw200hourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.10 | Columnrsw200flashPrgCntA | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.11 | Columnrsw200flashPrgCntB | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.12 | Columnrsw200flashBankARev | read-only | mandatory | This object provides the revision of flash bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.8.5.4.13 | Columnrsw200flashBankBRev | read-only | mandatory | This object provides the revision of flash bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.8.6 | Tablegx2Rsw200bHoldTimeTable | not-accessible | mandatory | This table contains gx2Rsw200b specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.8.6 | NodetrapRSW200FlashAlarm | This trap is issued when the detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.8.6.5 | Rowgx2Rsw200bHoldTimeEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.8.6.5.1 | Columnrxgx2Rsw200bHoldTimeTableIndex | read-only | mandatory | The value of this object is the index of the data object. |
| 1.3.6.1.4.1.1166.6.1.2.8.6.5.2 | Columnrxgx2Rsw200bHoldTimeSpecIndex | read-only | mandatory | The value of this object identifies the index of the alarm object to be modified. |
| 1.3.6.1.4.1.1166.6.1.2.8.6.5.3 | Columnrxgx2Rsw200bHoldTimeData | read-write | mandatory | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered… |
| 1.3.6.1.4.1.1166.6.1.2.8.7 | NodetrapRSW200BankBootAlarm | This trap is issued when the detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.8.8 | NodetrapRSW200AlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.8.9 | NodetrapRSW200FactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.8.10 | NodetrapRSW200InputSwitchedAlarm | This trap is issued when the RF input switched. | ||
| 1.3.6.1.4.1.1166.6.1.2.8.11 | NodetrapRSW200ResetFactoryDefaultAlarm | This trap is issued when the Factory Default Reset occurs. | ||
| 1.3.6.1.4.1.1166.6.1.2.8.12 | NodetrapRSW200SecondaryInputActiveAlarm | This trap is issued when the scondary input becomes active. |