MIB Viewer

OMNI-gx2RX1000-MIB

146 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.9.1Nodegx2Rx1000Descriptor
1.3.6.1.4.1.1166.6.1.2.9.1NodetrapRX1000ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.9.2Tablegx2Rx1000AnalogTablenot-accessiblemandatoryThis table contains gx2Rx1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.9.2NodetrapRX1000ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.9.2.1Rowgx2Rx1000AnalogEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.9.2.1.1Columnfprgx2Rx1000AnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.9.2.1.2ColumnfprlabelOptPowerread-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.3ColumnfpruomOptPowerread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.4ColumnfprmajorHighOptPowerread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.9.2.1.5ColumnfprmajorLowOptPowerread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.9.2.1.6ColumnfprminorHighOptPowerread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.9.2.1.7ColumnfprminorLowOptPowerread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.9.2.1.8ColumnfprcurrentValueOptPowerread-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.9.2.1.9ColumnfprstateFlagOptPowerread-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.2.1.10ColumnfprminValueOptPowerread-onlymandatoryThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.9.2.1.11ColumnfprmaxValueOptPowerread-onlymandatoryThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.9.2.1.12ColumnfpralarmStateOptPowerread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.13ColumnfprlabelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.14ColumnfpruomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.15ColumnfprmajorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.9.2.1.16ColumnfprmajorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.9.2.1.17ColumnfprminorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.9.2.1.18ColumnfprminorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.9.2.1.19ColumnfprcurrentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.9.2.1.20ColumnfprstateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.2.1.21ColumnfprminValueModTempread-onlymandatoryThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.9.2.1.22ColumnfprmaxValueModTempread-onlymandatoryThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.9.2.1.23ColumnfpralarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.24ColumnfprlabelSinkTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.25ColumnfpruomSinkTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.26ColumnfprmajorHighSinkTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.9.2.1.27ColumnfprmajorLowSinkTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.9.2.1.28ColumnfprminorHighSinkTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.9.2.1.29ColumnfprminorLowSinkTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.9.2.1.30ColumnfprcurrentValueSinkTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.9.2.1.31ColumnfprstateFlagSinkTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.2.1.32ColumnfprminValueSinkTempread-onlymandatoryThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.9.2.1.33ColumnfprmaxValueSinkTempread-onlymandatoryThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.9.2.1.34ColumnfpralarmStateSinkTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.35ColumnfprlabelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.36ColumnfpruomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.37ColumnfprmajorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.9.2.1.38ColumnfprmajorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.9.2.1.39ColumnfprminorHighFanCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.9.2.1.40ColumnfprminorLowFanCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.9.2.1.41ColumnfprcurrentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.9.2.1.42ColumnfprstateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.2.1.43ColumnfprminValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.9.2.1.44ColumnfprmaxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.9.2.1.45ColumnfpralarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.46Columnfprlabel12Voltread-onlyoptionalThe value of this object provides the label of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.47Columnfpruom12Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.2.1.48ColumnfprmajorHigh12Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.9.2.1.49ColumnfprmajorLow12Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.9.2.1.50ColumnfprminorHigh12Voltread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.9.2.1.51ColumnfprminorLow12Voltread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.9.2.1.52ColumnfprcurrentValue12Voltread-onlymandatoryThe value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.9.2.1.53ColumnfprstateFlag12Voltread-onlymandatoryThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.2.1.54ColumnfprminValue12Voltread-onlymandatoryThe value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.9.2.1.55ColumnfprmaxValue12Voltread-onlymandatoryThe value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.9.2.1.56ColumnfpralarmState12Voltread-onlymandatoryThe value of this object provides the curent alarm state of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.9.3Tablegx2Rx1000DigitalTablenot-accessiblemandatoryThis table contains gx2Rx1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.9.3NodetrapRX1000OpticalPowerAlarmThis trap is issued when the input Optical Power parameter goes out of range.
1.3.6.1.4.1.1166.6.1.2.9.3.2Rowgx2Rx1000DigitalEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.9.3.2.1Columnfprgx2Rx1000DigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.9.3.2.2ColumnfprlabelSlopeSettingread-onlyoptionalThe value of this object provides the label of the RX1000's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.9.3.2.3ColumnfprenumSlopeSettingread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.9.3.2.4ColumnfprvalueSlopeSettingread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 6. Each increment represents 1/2 dB of slope from 0 to 3 dB. W…
1.3.6.1.4.1.1166.6.1.2.9.3.2.5ColumnfprstateFlagSlopeSettingread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.3.2.6ColumnfprlabelAttnSettingread-onlyoptionalThe value of this object provides the label of the RX1000's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.9.3.2.7ColumnfprenumAttnSettingread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.9.3.2.8ColumnfprvalueAttnSettingread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/4 dB of attenuation from 0 to …
1.3.6.1.4.1.1166.6.1.2.9.3.2.9ColumnfprstateFlagAttnSettingread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.3.2.10ColumnfprlabelWavelengthread-onlyoptionalThe value of this object provides the label of the RX1000's Wavelength Digital parameter.
1.3.6.1.4.1.1166.6.1.2.9.3.2.11ColumnfprenumWavelengthread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value …
1.3.6.1.4.1.1166.6.1.2.9.3.2.12ColumnfprvalueWavelengthread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.9.3.2.13ColumnfprstateFlagWavelengthread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.3.2.14ColumnfprlabelFactoryDefaultread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.9.3.2.15ColumnfprenumFactoryDefaultread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.9.3.2.16ColumnfprvalueFactoryDefaultread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.9.3.2.17ColumnfprstateFlagFactoryDefaultread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.3.2.18ColumnfprlabelSwModeThresholdread-onlyoptionalThe value of this object provides the label of the RX1000's Switch Mode Threshold Digital parameter.
1.3.6.1.4.1.1166.6.1.2.9.3.2.19ColumnfprenumSwModeThresholdread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value …
1.3.6.1.4.1.1166.6.1.2.9.3.2.20ColumnfprvalueSwModeThresholdread-writemandatoryThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 0.5 dB increments ranging from -9 to …
1.3.6.1.4.1.1166.6.1.2.9.3.2.21ColumnfprstateFlagSwModeThresholdread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.3.2.22ColumnfprlabelSwModeSettingread-onlyoptionalThe value of this object provides the label of the RX1000's Switch Mode Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.9.3.2.23ColumnfprenumSwModeSettingread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.9.3.2.24ColumnfprvalueSwModeSettingread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.9.3.2.25ColumnfprstateFlagSwModeSettingread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.4Tablegx2Rx1000StatusTablenot-accessiblemandatoryThis table contains gx2Rx1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.9.4NodetrapRX1000ModuleTemperatureAlarmThis trap is issued when the RX1000 Module's Temperature goes out of range.
1.3.6.1.4.1.1166.6.1.2.9.4.3Rowgx2Rx1000StatusEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.9.4.3.1Columnfprgx2Rx1000StatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.9.4.3.2ColumnfprlabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.9.4.3.3ColumnfprvalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.9.4.3.4ColumnfprstateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.4.3.5ColumnfprlabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.9.4.3.6ColumnfprvalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.9.4.3.7ColumnfprstateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.4.3.8ColumnfprlabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.9.4.3.9ColumnfprvalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.9.4.3.10ColumnfprstateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.4.3.11ColumnfprlabelAlarmDataCRCread-onlyoptionalThe value of this object provides the label of the Alarm Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.9.4.3.12ColumnfprvalueAlarmDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.9.4.3.13ColumnfprstateflagAlarmDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.4.3.14ColumnfprlabelCalibrationDataCRCread-onlyoptionalThe value of this object provides the label of the Calibration Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.9.4.3.15ColumnfprvalueCalibrationDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.9.4.3.16ColumnfprstateflagCalibrationDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.4.3.17ColumnfprlabelFacCalSettingCRCread-onlyoptionalThe value of this object provides the label of the Factor Cal Setting CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.9.4.3.18ColumnfprvalueFacCalSettingCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.9.4.3.19ColumnfprstateflagFacCalSettingCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.4.3.20ColumnfprlabelInputSigread-onlyoptionalThe value of this object provides the label of the Input Sig Status parameter.
1.3.6.1.4.1.1166.6.1.2.9.4.3.21ColumnfprvalueInputSigread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.9.4.3.22ColumnfprstateflagInputSigread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.9.5Tablegx2Rx1000FactoryTablenot-accessiblemandatoryThis table contains gx2Rx1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.9.5NodetrapRX1000HeatSinkTemperatureAlarmThis trap is issued when the RX1000 Heat Sink Temperature goes out of range.
1.3.6.1.4.1.1166.6.1.2.9.5.4Rowgx2Rx1000FactoryEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.9.5.4.1Columnfprgx2Rx1000FactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.9.5.4.2ColumnfprbootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.9.5.4.3ColumnfprbootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.9.5.4.4Columnfprbank0CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.9.5.4.5Columnfprbank1CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.9.5.4.6ColumnfprprgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.9.5.4.7ColumnfprfactoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.9.5.4.8ColumnfprcalculateCRCread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.9.5.4.9ColumnfprhourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.9.5.4.10ColumnfprflashPrgCntAread-onlymandatoryThis object provides the number of times the flash has been programmed on side A.
1.3.6.1.4.1.1166.6.1.2.9.5.4.11ColumnfprflashPrgCntBread-onlymandatoryThis object provides the number of times the flash has been programmed on side B.
1.3.6.1.4.1.1166.6.1.2.9.5.4.12ColumnfprfwRev0read-onlymandatoryThis object provides the Revision of the firmware stores in bank 0.
1.3.6.1.4.1.1166.6.1.2.9.5.4.13ColumnfprfwRev1read-onlymandatoryThis object provides the Revision of the firmware stores in bank 1.
1.3.6.1.4.1.1166.6.1.2.9.6Tablegx2Rx1000HoldTimeTablenot-accessiblemandatoryThis table contains gx2Rx1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.9.6NodetrapRX1000FanCurrentAlarmThis trap is issued when the RX1000 Module's Fan Currrent parameter goes out of range.
1.3.6.1.4.1.1166.6.1.2.9.6.5Rowgx2Rx1000HoldTimeEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.9.6.5.1Columngx2Rx1000HoldTimeTableIndexread-onlymandatoryThe value of this object is the index of the data object.
1.3.6.1.4.1.1166.6.1.2.9.6.5.2Columngx2Rx1000HoldTimeSpecIndexread-onlymandatoryThe value of this object identifies the index of the alarm object to be modified.
1.3.6.1.4.1.1166.6.1.2.9.6.5.3Columngx2Rx1000HoldTimeDataread-writemandatoryThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered…
1.3.6.1.4.1.1166.6.1.2.9.7NodetrapRX1000Plus12CurrentAlarmThis trap is issued when the RX1000 Module's positive 12 volt current parameter goes out of range.
1.3.6.1.4.1.1166.6.1.2.9.8NodetrapRX1000OpticalSwitchAlarmThis trap is issued when the RX1000 Redundancy signal indicates a low input signal.
1.3.6.1.4.1.1166.6.1.2.9.9NodetrapRX1000Boot0AlarmThis trap is issued when the RX1000 Module's Bank 0 Boot sequence has detected an error.
1.3.6.1.4.1.1166.6.1.2.9.10NodetrapRX1000Boot1AlarmThis trap is issued when the RX1000 Module's Bank 1 Boot sequence has detected an error.
1.3.6.1.4.1.1166.6.1.2.9.11NodetrapRX1000FlashAlarmThis trap is issued when the RX1000 Module's boot or flash programming sequence has detected a Flash error.
1.3.6.1.4.1.1166.6.1.2.9.12NodetrapRX1000AlarmDataCRCAlarmThis trap is issued when the RX1000 Module detects an error calculating the alarm limit CRC.
1.3.6.1.4.1.1166.6.1.2.9.13NodetrapRX1000FactoryDataCRCAlarmThis trap is issued when the RX1000 Module detects an error calculating the Factory data CRC.
1.3.6.1.4.1.1166.6.1.2.9.14NodetrapRX1000CalDataCRCAlarmThis trap is issued when the RX1000 Module detects an error calculating the Calibration data CRC.
1.3.6.1.4.1.1166.6.1.2.9.15NodetrapRX1000ResetFacDefaultThis trap is issued when the RX1000 resets to factory defaults
1.3.6.1.4.1.1166.6.1.2.9.16NodetrapRX1000FacCalSettingCRCAlarmThis trap is issued when the RX1000 Module detects factory calibration setting CRC alarm.