OMNI-gx2RX200-MIB
138 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.6.1 | Nodegx2Rx200Descriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.6.1 | NodetrapRX200ConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.6.2 | Tablegx2Rx200AnalogTable | not-accessible | mandatory | This table contains gx2Rx200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.6.2 | NodetrapRX200ConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.6.2.1 | Rowgx2Rx200AnalogEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.1 | Columnrxgx2Rx200AnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.2 | ColumnrxlabelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.3 | ColumnrxuomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.4 | ColumnrxmajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.5 | ColumnrxmajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.6 | ColumnrxminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.7 | ColumnrxminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.8 | ColumnrxcurrentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.9 | ColumnrxstateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.10 | ColumnrxminValueModTemp | read-only | mandatory | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.11 | ColumnrxmaxValueModTemp | read-only | mandatory | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.12 | ColumnrxalarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.13 | ColumnrxlabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.14 | ColumnrxuomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.15 | ColumnrxmajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.16 | ColumnrxmajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.17 | ColumnrxminorHighFanCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.18 | ColumnrxminorLowFanCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.19 | ColumnrxcurrentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.20 | ColumnrxstateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.21 | ColumnrxminValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.22 | ColumnrxmaxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.23 | ColumnrxalarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.24 | Columnrxlabel12Volt | read-only | optional | The value of this object provides the label of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.25 | Columnrxuom12Volt | read-only | optional | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.26 | ColumnrxmajorHigh12Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.27 | ColumnrxmajorLow12Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.28 | ColumnrxminorHigh12Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.29 | ColumnrxminorLow12Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.30 | ColumnrxcurrentValue12Volt | read-only | mandatory | The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.31 | ColumnrxstateFlag12Volt | read-only | mandatory | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.32 | ColumnrxminValue12Volt | read-only | mandatory | The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.33 | ColumnrxmaxValue12Volt | read-only | mandatory | The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.34 | ColumnrxalarmState12Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.35 | ColumnrxlabelOptPower | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.36 | ColumnrxuomOptPower | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.37 | ColumnrxmajorHighOptPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.38 | ColumnrxmajorLowOptPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.39 | ColumnrxminorHighOptPower | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.40 | ColumnrxminorLowOptPower | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.41 | ColumnrxcurrentValueOptPower | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.42 | ColumnrxstateFlagOptPower | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.43 | ColumnrxminValueOptPower | read-only | mandatory | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.44 | ColumnrxmaxValueOptPower | read-only | mandatory | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.6.2.1.45 | ColumnrxalarmStateOptPower | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3 | Tablegx2Rx200DigitalTable | not-accessible | mandatory | This table contains gx2Rx200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.6.3 | NodetrapRX200OpticalPowerAlarm | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this p… | ||
| 1.3.6.1.4.1.1166.6.1.2.6.3.2 | Rowgx2Rx200DigitalEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.1 | Columnrxgx2Rx200DigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.2 | ColumnrxlabelMode | read-only | optional | The value of this object provides the label of the RX200's Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.3 | ColumnrxenumMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.4 | ColumnrxvalueMode | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.5 | ColumnrxstateFlagMode | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.6 | ColumnrxlabelWavelength | read-only | optional | The value of this object provides the label of the RX200's Wavelength Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.7 | ColumnrxenumWavelength | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.8 | ColumnrxvalueWavelength | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.9 | ColumnrxstateFlagWavelength | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.10 | ColumnrxlabelAttnSetting | read-only | optional | The value of this object provides the label of the RX200's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.11 | ColumnrxenumAttnSetting | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.12 | ColumnrxvalueAttnSetting | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to … |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.13 | ColumnrxstateFlagAttnSetting | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.14 | ColumnrxlabelSwModeSetting | read-only | optional | The value of this object provides the label of the RX200's Switch Mode Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.15 | ColumnrxenumSwModeSetting | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.16 | ColumnrxvalueSwModeSetting | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.17 | ColumnrxstateFlagSwModeSetting | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.18 | ColumnrxlabelSwModeThreshold | read-only | optional | The value of this object provides the label of the RX200's Switch Mode Threshold Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.19 | ColumnrxenumSwModeThreshold | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.20 | ColumnrxvalueSwModeThreshold | read-write | mandatory | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1… |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.21 | ColumnrxstateFlagSwModeThreshold | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.22 | ColumnrxlabelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.23 | ColumnrxenumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.24 | ColumnrxvalueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.3.2.25 | ColumnrxstateFlagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.4 | Tablegx2Rx200StatusTable | not-accessible | mandatory | This table contains gx2Rx200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.6.4 | NodetrapRX200ModuleTemperatureAlarm | This trap is issued when the RX200 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.6.4.3 | Rowgx2Rx200StatusEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.1 | Columnrxgx2Rx200StatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.2 | ColumnrxlabelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.3 | ColumnrxvalueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.4 | ColumnrxstateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.5 | ColumnrxlabelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.6 | ColumnrxvalueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.7 | ColumnrxstateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.8 | ColumnrxlabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.9 | ColumnrxvalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.10 | ColumnrxstateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.11 | ColumnrxlabelAlarmDataCRC | read-only | optional | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.12 | ColumnrxvalueAlarmDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.13 | ColumnrxstateflagAlarmDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.14 | ColumnrxlabelCalibrationDataCRC | read-only | optional | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.15 | ColumnrxvalueCalibrationDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.16 | ColumnrxstateflagCalibrationDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.17 | ColumnrxlabelThermalCompCRC | read-only | optional | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.18 | ColumnrxvalueThermalCompCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.19 | ColumnrxstateflagThermalCompCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.20 | ColumnrxlabelHW | read-only | optional | The value of this object provides the label of the Hardware Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.21 | ColumnrxvalueHW | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.22 | ColumnrxstateflagHW | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.23 | ColumnrxlabelOptSig | read-only | optional | The value of this object provides the label of the Optical Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.24 | ColumnrxvalueOptSig | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.6.4.3.25 | ColumnrxstateflagOptSig | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.6.5 | Tablegx2Rx200FactoryTable | not-accessible | mandatory | This table contains gx2Rx200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.6.5 | NodetrapRX200FanCurrentAlarm | This trap is issued when the RX200 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this pa… | ||
| 1.3.6.1.4.1.1166.6.1.2.6.5.4 | Rowgx2Rx200FactoryEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.1 | Columnrxgx2Rx200FactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.2 | ColumnrxbootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.3 | ColumnrxbootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.4 | Columnrxbank0CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.5 | Columnrxbank1CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.6 | ColumnrxprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.7 | ColumnrxfactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.8 | ColumnrxcalculateCRC | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.9 | ColumnrxhourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.10 | ColumnrxflashPrgCntA | read-only | mandatory | This object provides the number of times the flash has been programmed on side A. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.11 | ColumnrxflashPrgCntB | read-only | mandatory | This object provides the number of times the flash has been programmed on side B. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.12 | ColumnrxfwRev0 | read-only | mandatory | This object provides the Revision of the firmware stores in bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.6.5.4.13 | ColumnrxfwRev1 | read-only | mandatory | This object provides the Revision of the firmware stores in bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.6.6 | Tablegx2Rx200HoldTimeTable | not-accessible | mandatory | This table contains gx2Rx200 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.6.6 | NodetrapRX200Plus12CurrentAlarm | This trap is issued when the RX200 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of… | ||
| 1.3.6.1.4.1.1166.6.1.2.6.6.5 | Rowgx2Rx200HoldTimeEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.6.6.5.1 | Columnrxgx2Rx200HoldTimeTableIndex | read-only | mandatory | The value of this object is the index of the data object. |
| 1.3.6.1.4.1.1166.6.1.2.6.6.5.2 | Columnrxgx2Rx200HoldTimeSpecIndex | read-only | mandatory | The value of this object identifies the index of the alarm object to be modified. |
| 1.3.6.1.4.1.1166.6.1.2.6.6.5.3 | Columnrxgx2Rx200HoldTimeData | read-write | mandatory | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered… |
| 1.3.6.1.4.1.1166.6.1.2.6.7 | NodetrapRX200Boot0Alarm | This trap is issued when the RX200 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this … | ||
| 1.3.6.1.4.1.1166.6.1.2.6.8 | NodetrapRX200Boot1Alarm | This trap is issued when the RX200 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this … | ||
| 1.3.6.1.4.1.1166.6.1.2.6.9 | NodetrapRX200FlashAlarm | This trap is issued when the RX200 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current r… | ||
| 1.3.6.1.4.1.1166.6.1.2.6.10 | NodetrapRX200AlarmDataCRCAlarm | This trap is issued when the RX200 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the … | ||
| 1.3.6.1.4.1.1166.6.1.2.6.11 | NodetrapRX200FactoryDataCRCAlarm | This trap is issued when the RX200 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the… | ||
| 1.3.6.1.4.1.1166.6.1.2.6.12 | NodetrapRX200CalDataCRCAlarm | This trap is issued when the RX200 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of… | ||
| 1.3.6.1.4.1.1166.6.1.2.6.13 | NodetrapRX200DefaultAlarm | This trap is issued when the RX200 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this param… | ||
| 1.3.6.1.4.1.1166.6.1.2.6.14 | NodetrapRX200ModeAlarm | This trap is issued when the RX200 Modules mode is changed from normal to off or off to normal. trapAdditionalInfoInteger variable contains current reading of … | ||
| 1.3.6.1.4.1.1166.6.1.2.6.15 | NodetrapRX200OutputSwitchedAlarm | This trap is issued when the RX200 Module's output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable co… | ||
| 1.3.6.1.4.1.1166.6.1.2.6.16 | NodetrapRX200SideStatusAlarm | This trap is issued when one of the RX200 Module's outputs are turned on or off. |