MIB Viewer

OMNI-gx2Rx085BX4-MIB

264 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.32.1Nodegx2Rx085BX4Descriptor
1.3.6.1.4.1.1166.6.1.2.32.1NodetrapRx085BX4ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.32.2Tablegx2Rx085BX4AnalogTablenot-accessiblemandatoryThis table contains gx2Rx085BX4 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.32.2NodetrapRx085BX4ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.32.2.1Rowgx2Rx085BX4AnalogEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.32.2.1.1Columngx2Rx085BX4AnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.32.2.1.2Columnrx085labelOptPowerOneread-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.3Columnrx085uomOptPowerOneread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.4Columnrx085majorHighOptPowerOneread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.32.2.1.5Columnrx085majorLowOptPowerOneread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.32.2.1.6Columnrx085minorHighOptPowerOneread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.32.2.1.7Columnrx085minorLowOptPowerOneread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.32.2.1.8Columnrx085currentValueOptPowerOneread-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.9Columnrx085stateFlagOptPowerOneread-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.2.1.10Columnrx085minValueOptPowerOneread-onlymandatoryThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.11Columnrx085maxValueOptPowerOneread-onlymandatoryThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.12Columnrx085alarmStateOptPowerOneread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.13Columnrx085labelOptPowerTworead-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.14Columnrx085uomOptPowerTworead-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.15Columnrx085majorHighOptPowerTworead-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.32.2.1.16Columnrx085majorLowOptPowerTworead-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.32.2.1.17Columnrx085minorHighOptPowerTworead-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.32.2.1.18Columnrx085minorLowOptPowerTworead-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.32.2.1.19Columnrx085currentValueOptPowerTworead-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.20Columnrx085stateFlagOptPowerTworead-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.2.1.21Columnrx085minValueOptPowerTworead-onlymandatoryThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.22Columnrx085maxValueOptPowerTworead-onlymandatoryThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.23Columnrx085alarmStateOptPowerTworead-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.24Columnrx085labelOptPowerThreeread-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.25Columnrx085uomOptPowerThreeread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.26Columnrx085majorHighOptPowerThreeread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.32.2.1.27Columnrx085majorLowOptPowerThreeread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.32.2.1.28Columnrx085minorHighOptPowerThreeread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.32.2.1.29Columnrx085minorLowOptPowerThreeread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.32.2.1.30Columnrx085currentValueOptPowerThreeread-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.31Columnrx085stateFlagOptPowerThreeread-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.2.1.32Columnrx085minValueOptPowerThreeread-onlymandatoryThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.33Columnrx085maxValueOptPowerThreeread-onlymandatoryThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.34Columnrx085alarmStateOptPowerThreeread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.35Columnrx085labelOptPowerFourread-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.36Columnrx085uomOptPowerFourread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.37Columnrx085majorHighOptPowerFourread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.32.2.1.38Columnrx085majorLowOptPowerFourread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.32.2.1.39Columnrx085minorHighOptPowerFourread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.32.2.1.40Columnrx085minorLowOptPowerFourread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.32.2.1.41Columnrx085currentValueOptPowerFourread-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.42Columnrx085stateFlagOptPowerFourread-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.2.1.43Columnrx085minValueOptPowerFourread-onlymandatoryThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.44Columnrx085maxValueOptPowerFourread-onlymandatoryThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.45Columnrx085alarmStateOptPowerFourread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.46Columnrx085labelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.47Columnrx085uomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.48Columnrx085majorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.32.2.1.49Columnrx085majorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.32.2.1.50Columnrx085minorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.32.2.1.51Columnrx085minorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.32.2.1.52Columnrx085currentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.32.2.1.53Columnrx085stateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.2.1.54Columnrx085minValueModTempread-onlymandatoryThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.32.2.1.55Columnrx085maxValueModTempread-onlymandatoryThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.32.2.1.56Columnrx085alarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.57Columnrx085labelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.58Columnrx085uomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.59Columnrx085majorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.32.2.1.60Columnrx085majorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.32.2.1.61Columnrx085minorHighFanCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.32.2.1.62Columnrx085minorLowFanCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.32.2.1.63Columnrx085currentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.32.2.1.64Columnrx085stateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.2.1.65Columnrx085minValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.32.2.1.66Columnrx085maxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.32.2.1.67Columnrx085alarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.68Columnrx085label12Voltread-onlyoptionalThe value of this object provides the label of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.69Columnrx085uom12Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.2.1.70Columnrx085majorHigh12Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.32.2.1.71Columnrx085majorLow12Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.32.2.1.72Columnrx085minorHigh12Voltread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.32.2.1.73Columnrx085minorLow12Voltread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.32.2.1.74Columnrx085currentValue12Voltread-onlymandatoryThe value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.75Columnrx085stateFlag12Voltread-onlymandatoryThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.2.1.76Columnrx085minValue12Voltread-onlymandatoryThe value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.77Columnrx085maxValue12Voltread-onlymandatoryThe value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.32.2.1.78Columnrx085alarmState12Voltread-onlymandatoryThe value of this object provides the curent alarm state of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.32.3Tablegx2Rx085BX4DigitalTablenot-accessiblemandatoryThis table contains gx2Rx085BX4 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.32.3NodetrapRx085BX4OpticalPower1AlarmThis trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the…
1.3.6.1.4.1.1166.6.1.2.32.3.2Rowgx2Rx085BX4DigitalEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.32.3.2.1Columngx2Rx085BX4DigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.32.3.2.2Columnrx085labelModeOneread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.3Columnrx085enumModeOneread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.4Columnrx085valueModeOneread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.5Columnrx085stateFlagModeOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.6Columnrx085labelWavelengthOneread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Wavelength Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.7Columnrx085enumWavelengthOneread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.8Columnrx085valueWavelengthOneread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.9Columnrx085stateFlagWavelengthOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.10Columnrx085labelAttnSettingOneread-onlyoptionalThe value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.11Columnrx085enumAttnSettingOneread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.12Columnrx085valueAttnSettingOneread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 60. Each increment represents 1/2 dB of attenuation from 0 to …
1.3.6.1.4.1.1166.6.1.2.32.3.2.13Columnrx085stateFlagAttnSettingOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.14Columnrx085labelSwModeSettingOneread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.15Columnrx085enumSwModeSettingOneread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.16Columnrx085valueSwModeSettingOneread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.17Columnrx085stateFlagSwModeSettingOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.18Columnrx085labelSwModeThresholdOneread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.19Columnrx085enumSwModeThresholdOneread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.20Columnrx085valueSwModeThresholdOneread-writemandatoryThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1…
1.3.6.1.4.1.1166.6.1.2.32.3.2.21Columnrx085stateFlagSwModeThresholdOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.22Columnrx085labelModeTworead-onlyoptionalThe value of this object provides the label of the Rx085BX4's Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.23Columnrx085enumModeTworead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.24Columnrx085valueModeTworead-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.25Columnrx085stateFlagModeTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.26Columnrx085labelWavelengthTworead-onlyoptionalThe value of this object provides the label of the Rx085BX4's Wavelength Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.27Columnrx085enumWavelengthTworead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.28Columnrx085valueWavelengthTworead-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.29Columnrx085stateFlagWavelengthTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.30Columnrx085labelAttnSettingTworead-onlyoptionalThe value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.31Columnrx085enumAttnSettingTworead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.32Columnrx085valueAttnSettingTworead-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to …
1.3.6.1.4.1.1166.6.1.2.32.3.2.33Columnrx085stateFlagAttnSettingTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.34Columnrx085labelSwModeSettingTworead-onlyoptionalThe value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.35Columnrx085enumSwModeSettingTworead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.36Columnrx085valueSwModeSettingTworead-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.37Columnrx085stateFlagSwModeSettingTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.38Columnrx085labelSwModeThresholdTworead-onlyoptionalThe value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.39Columnrx085enumSwModeThresholdTworead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.40Columnrx085valueSwModeThresholdTworead-writemandatoryThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1…
1.3.6.1.4.1.1166.6.1.2.32.3.2.41Columnrx085stateFlagSwModeThresholdTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.42Columnrx085labelModeThreeread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.43Columnrx085enumModeThreeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.44Columnrx085valueModeThreeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.45Columnrx085stateFlagModeThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.46Columnrx085labelWavelengthThreeread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Wavelength Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.47Columnrx085enumWavelengthThreeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.48Columnrx085valueWavelengthThreeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.49Columnrx085stateFlagWavelengthThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.50Columnrx085labelAttnSettingThreeread-onlyoptionalThe value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.51Columnrx085enumAttnSettingThreeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.52Columnrx085valueAttnSettingThreeread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to …
1.3.6.1.4.1.1166.6.1.2.32.3.2.53Columnrx085stateFlagAttnSettingThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.54Columnrx085labelSwModeSettingThreeread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.55Columnrx085enumSwModeSettingThreeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.56Columnrx085valueSwModeSettingThreeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.57Columnrx085stateFlagSwModeSettingThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.58Columnrx085labelSwModeThresholdThreeread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.59Columnrx085enumSwModeThresholdThreeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.60Columnrx085valueSwModeThresholdThreeread-writemandatoryThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1…
1.3.6.1.4.1.1166.6.1.2.32.3.2.61Columnrx085stateFlagSwModeThresholdThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.62Columnrx085labelModeFourread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.63Columnrx085enumModeFourread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.64Columnrx085valueModeFourread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.65Columnrx085stateFlagModeFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.66Columnrx085labelWavelengthFourread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Wavelength Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.67Columnrx085enumWavelengthFourread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.68Columnrx085valueWavelengthFourread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.69Columnrx085stateFlagWavelengthFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.70Columnrx085labelAttnSettingFourread-onlyoptionalThe value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.71Columnrx085enumAttnSettingFourread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.72Columnrx085valueAttnSettingFourread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to …
1.3.6.1.4.1.1166.6.1.2.32.3.2.73Columnrx085stateFlagAttnSettingFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.74Columnrx085labelSwModeSettingFourread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.75Columnrx085enumSwModeSettingFourread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.76Columnrx085valueSwModeSettingFourread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.77Columnrx085stateFlagSwModeSettingFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.78Columnrx085labelSwModeThresholdFourread-onlyoptionalThe value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.79Columnrx085enumSwModeThresholdFourread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.80Columnrx085valueSwModeThresholdFourread-writemandatoryThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1…
1.3.6.1.4.1.1166.6.1.2.32.3.2.81Columnrx085stateFlagSwModeThresholdFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.82Columnrx085labelModuleConfigread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.83Columnrx085enumModuleConfigread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.84Columnrx085valueModuleConfigread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.85Columnrx085stateFlagModuleConfigread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.86Columnrx085labelRevertTimeread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.87Columnrx085enumRevertTimeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.88Columnrx085valueRevertTimeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.89Columnrx085stateFlagRevertTimeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.90Columnrx085labelTestPointSelectread-onlyoptionalThe value of this object provides the label of the Test point Select Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.91Columnrx085enumTestPointSelectread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.92Columnrx085valueTestPointSelectread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.93Columnrx085stateFlagTestPointSelectread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.3.2.94Columnrx085labelFactoryDefaultread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.95Columnrx085enumFactoryDefaultread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.32.3.2.96Columnrx085valueFactoryDefaultread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.32.3.2.97Columnrx085stateFlagFactoryDefaultread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4Tablegx2Rx085BX4StatusTablenot-accessiblemandatoryThis table contains gx2Rx085BX4 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.32.4NodetrapRx085BX4OpticalPower2AlarmThis trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the…
1.3.6.1.4.1.1166.6.1.2.32.4.3Rowgx2Rx085BX4StatusEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.32.4.3.1Columngx2Rx085BX4StatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.32.4.3.2Columnrx085labelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.3Columnrx085valueBootread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.4Columnrx085stateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4.3.5Columnrx085labelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.6Columnrx085valueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.7Columnrx085stateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4.3.8Columnrx085labelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.9Columnrx085valueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.10Columnrx085stateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4.3.11Columnrx085labelAlarmDataCRCread-onlyoptionalThe value of this object provides the label of the Alarm Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.12Columnrx085valueAlarmDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.13Columnrx085stateflagAlarmDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4.3.14Columnrx085labelCalibrationDataCRCread-onlyoptionalThe value of this object provides the label of the Calibration Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.15Columnrx085valueCalibrationDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.16Columnrx085stateflagCalibrationDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4.3.17Columnrx085labelHWread-onlyoptionalThe value of this object provides the label of the Hardware Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.18Columnrx085valueHWread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.19Columnrx085stateflagHWread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4.3.20Columnrx085labelOptSigOneread-onlyoptionalThe value of this object provides the label of the Optical Signal Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.21Columnrx085valueOptSigOneread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.22Columnrx085stateflagOptSigOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4.3.23Columnrx085labelOptSigTworead-onlyoptionalThe value of this object provides the label of the Optical Signal Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.24Columnrx085valueOptSigTworead-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.25Columnrx085stateflagOptSigTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4.3.26Columnrx085labelOptSigThreeread-onlyoptionalThe value of this object provides the label of the Optical Signal Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.27Columnrx085valueOptSigThreeread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.28Columnrx085stateflagOptSigThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4.3.29Columnrx085labelOptSigFourread-onlyoptionalThe value of this object provides the label of the Optical Signal Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.30Columnrx085valueOptSigFourread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.31Columnrx085stateflagOptSigFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.4.3.32Columnrx085labelBackupCableread-onlyoptionalThe value of this object provides the label of the Backup Cable Status parameter.
1.3.6.1.4.1.1166.6.1.2.32.4.3.33Columnrx085valueBackupCableread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.32.4.3.34Columnrx085stateflagBackupCableread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.32.5Tablegx2Rx085BX4FactoryTablenot-accessiblemandatoryThis table contains gx2Rx085BX4 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.32.5NodetrapRx085BX4OpticalPower3AlarmThis trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the…
1.3.6.1.4.1.1166.6.1.2.32.5.4Rowgx2Rx085BX4FactoryEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.32.5.4.1Columngx2Rx085BX4FactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.32.5.4.2Columnrx085bootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.32.5.4.3Columnrx085bootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.32.5.4.4Columnrx085bank0CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.32.5.4.5Columnrx085bank1CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.32.5.4.6Columnrx085prgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.32.5.4.7Columnrx085factoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.32.5.4.8Columnrx085calculateCRCread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.32.5.4.9Columnrx085hourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.32.5.4.10Columnrx085flashPrgCntAread-onlymandatoryThis object provides the number of times the flash has been programmed on side A.
1.3.6.1.4.1.1166.6.1.2.32.5.4.11Columnrx085flashPrgCntBread-onlymandatoryThis object provides the number of times the flash has been programmed on side B.
1.3.6.1.4.1.1166.6.1.2.32.5.4.12Columnrx085fwRev0read-onlymandatoryThis object provides the Revision of the firmware stores in bank 0.
1.3.6.1.4.1.1166.6.1.2.32.5.4.13Columnrx085fwRev1read-onlymandatoryThis object provides the Revision of the firmware stores in bank 1.
1.3.6.1.4.1.1166.6.1.2.32.6NodetrapRx085BX4OpticalPower4AlarmThis trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the…
1.3.6.1.4.1.1166.6.1.2.32.7NodetrapRx085BX4ModuleTemperatureAlarmThis trap is issued when the Rx085BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.32.8NodetrapRx085BX4FanCurrentAlarmThis trap is issued when the Rx085BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this…
1.3.6.1.4.1.1166.6.1.2.32.9NodetrapRx085BX4Plus12CurrentAlarmThis trap is issued when the Rx085BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading…
1.3.6.1.4.1.1166.6.1.2.32.10NodetrapRx085BX4Boot0AlarmThis trap is issued when the Rx085BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the th…
1.3.6.1.4.1.1166.6.1.2.32.11NodetrapRx085BX4Boot1AlarmThis trap is issued when the Rx085BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the th…
1.3.6.1.4.1.1166.6.1.2.32.12NodetrapRx085BX4FlashAlarmThis trap is issued when the Rx085BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains curren…
1.3.6.1.4.1.1166.6.1.2.32.13NodetrapRx085BX4AlarmDataCRCAlarmThis trap is issued when the Rx085BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of t…
1.3.6.1.4.1.1166.6.1.2.32.14NodetrapRx085BX4FactoryDataCRCAlarmThis trap is issued when the Rx085BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of …
1.3.6.1.4.1.1166.6.1.2.32.15NodetrapRx085BX4CalDataCRCAlarmThis trap is issued when the Rx085BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading…
1.3.6.1.4.1.1166.6.1.2.32.16NodetrapRx085BX4DefaultAlarmThis trap is issued when the Rx085BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this pa…
1.3.6.1.4.1.1166.6.1.2.32.17NodetrapRx085BX4Mode1AlarmThis trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren…
1.3.6.1.4.1.1166.6.1.2.32.18NodetrapRx085BX4Mode2AlarmThis trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren…
1.3.6.1.4.1.1166.6.1.2.32.19NodetrapRx085BX4Mode3AlarmThis trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren…
1.3.6.1.4.1.1166.6.1.2.32.20NodetrapRx085BX4Mode4AlarmThis trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren…
1.3.6.1.4.1.1166.6.1.2.32.21NodetrapRx085BX4Output1SwitchedAlarmThis trap is issued when the Rx085BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg…
1.3.6.1.4.1.1166.6.1.2.32.22NodetrapRx085BX4Output2SwitchedAlarmThis trap is issued when the Rx085BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg…
1.3.6.1.4.1.1166.6.1.2.32.23NodetrapRx085BX4Output3SwitchedAlarmThis trap is issued when the Rx085BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg…
1.3.6.1.4.1.1166.6.1.2.32.24NodetrapRx085BX4Output4SwitchedAlarmThis trap is issued when the Rx085BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg…
1.3.6.1.4.1.1166.6.1.2.32.25NodetrapRx085BX4RX1StatusAlarmThis trap is issued when receiver 1 of the Rx085BX4 Module output is turned on or off.
1.3.6.1.4.1.1166.6.1.2.32.26NodetrapRx085BX4RX2StatusAlarmThis trap is issued when receiver 2 of the Rx085BX4 Module output is turned on or off.
1.3.6.1.4.1.1166.6.1.2.32.27NodetrapRx085BX4RX3StatusAlarmThis trap is issued when receiver 3 of the Rx085BX4 Module output is turned on or off.
1.3.6.1.4.1.1166.6.1.2.32.28NodetrapRx085BX4RX4StatusAlarmThis trap is issued when receiver 4 of the Rx085BX4 Module output is turned on or off.
1.3.6.1.4.1.1166.6.1.2.32.29NodetrapRx085BX4BackupCableAlarmThis trap is issued when the slave receiver loses connection to the master receiver.
1.3.6.1.4.1.1166.6.1.2.32.30NodetrapRx085BX4OptPwr1BadAlarmThis trap is issued when the receiver 1 optical power level falls below the user set switching threshold.
1.3.6.1.4.1.1166.6.1.2.32.31NodetrapRx085BX4OptPwr2BadAlarmThis trap is issued when the receiver 2 optical power level falls below the user set switching threshold.
1.3.6.1.4.1.1166.6.1.2.32.32NodetrapRx085BX4OptPwr3BadAlarmThis trap is issued when the receiver 3 optical power level falls below the user set switching threshold.
1.3.6.1.4.1.1166.6.1.2.32.33NodetrapRx085BX4OptPwr4BadAlarmThis trap is issued when the receiver 4 optical power level falls below the user set switching threshold.