OMNI-gx2Rx085BX4-MIB
264 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.32.1 | Nodegx2Rx085BX4Descriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.32.1 | NodetrapRx085BX4ConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.2 | Tablegx2Rx085BX4AnalogTable | not-accessible | mandatory | This table contains gx2Rx085BX4 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.32.2 | NodetrapRx085BX4ConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.32.2.1 | Rowgx2Rx085BX4AnalogEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.1 | Columngx2Rx085BX4AnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.2 | Columnrx085labelOptPowerOne | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.3 | Columnrx085uomOptPowerOne | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.4 | Columnrx085majorHighOptPowerOne | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.5 | Columnrx085majorLowOptPowerOne | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.6 | Columnrx085minorHighOptPowerOne | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.7 | Columnrx085minorLowOptPowerOne | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.8 | Columnrx085currentValueOptPowerOne | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.9 | Columnrx085stateFlagOptPowerOne | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.10 | Columnrx085minValueOptPowerOne | read-only | mandatory | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.11 | Columnrx085maxValueOptPowerOne | read-only | mandatory | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.12 | Columnrx085alarmStateOptPowerOne | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.13 | Columnrx085labelOptPowerTwo | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.14 | Columnrx085uomOptPowerTwo | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.15 | Columnrx085majorHighOptPowerTwo | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.16 | Columnrx085majorLowOptPowerTwo | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.17 | Columnrx085minorHighOptPowerTwo | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.18 | Columnrx085minorLowOptPowerTwo | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.19 | Columnrx085currentValueOptPowerTwo | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.20 | Columnrx085stateFlagOptPowerTwo | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.21 | Columnrx085minValueOptPowerTwo | read-only | mandatory | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.22 | Columnrx085maxValueOptPowerTwo | read-only | mandatory | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.23 | Columnrx085alarmStateOptPowerTwo | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.24 | Columnrx085labelOptPowerThree | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.25 | Columnrx085uomOptPowerThree | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.26 | Columnrx085majorHighOptPowerThree | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.27 | Columnrx085majorLowOptPowerThree | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.28 | Columnrx085minorHighOptPowerThree | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.29 | Columnrx085minorLowOptPowerThree | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.30 | Columnrx085currentValueOptPowerThree | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.31 | Columnrx085stateFlagOptPowerThree | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.32 | Columnrx085minValueOptPowerThree | read-only | mandatory | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.33 | Columnrx085maxValueOptPowerThree | read-only | mandatory | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.34 | Columnrx085alarmStateOptPowerThree | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.35 | Columnrx085labelOptPowerFour | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.36 | Columnrx085uomOptPowerFour | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.37 | Columnrx085majorHighOptPowerFour | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.38 | Columnrx085majorLowOptPowerFour | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.39 | Columnrx085minorHighOptPowerFour | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.40 | Columnrx085minorLowOptPowerFour | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.41 | Columnrx085currentValueOptPowerFour | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.42 | Columnrx085stateFlagOptPowerFour | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.43 | Columnrx085minValueOptPowerFour | read-only | mandatory | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.44 | Columnrx085maxValueOptPowerFour | read-only | mandatory | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.45 | Columnrx085alarmStateOptPowerFour | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.46 | Columnrx085labelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.47 | Columnrx085uomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.48 | Columnrx085majorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.49 | Columnrx085majorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.50 | Columnrx085minorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.51 | Columnrx085minorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.52 | Columnrx085currentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.53 | Columnrx085stateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.54 | Columnrx085minValueModTemp | read-only | mandatory | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.55 | Columnrx085maxValueModTemp | read-only | mandatory | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.56 | Columnrx085alarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.57 | Columnrx085labelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.58 | Columnrx085uomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.59 | Columnrx085majorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.60 | Columnrx085majorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.61 | Columnrx085minorHighFanCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.62 | Columnrx085minorLowFanCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.63 | Columnrx085currentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.64 | Columnrx085stateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.65 | Columnrx085minValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.66 | Columnrx085maxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.67 | Columnrx085alarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.68 | Columnrx085label12Volt | read-only | optional | The value of this object provides the label of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.69 | Columnrx085uom12Volt | read-only | optional | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.70 | Columnrx085majorHigh12Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.71 | Columnrx085majorLow12Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.72 | Columnrx085minorHigh12Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.73 | Columnrx085minorLow12Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.74 | Columnrx085currentValue12Volt | read-only | mandatory | The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.75 | Columnrx085stateFlag12Volt | read-only | mandatory | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.76 | Columnrx085minValue12Volt | read-only | mandatory | The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.77 | Columnrx085maxValue12Volt | read-only | mandatory | The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.32.2.1.78 | Columnrx085alarmState12Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3 | Tablegx2Rx085BX4DigitalTable | not-accessible | mandatory | This table contains gx2Rx085BX4 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.32.3 | NodetrapRx085BX4OpticalPower1Alarm | This trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.3.2 | Rowgx2Rx085BX4DigitalEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.1 | Columngx2Rx085BX4DigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.2 | Columnrx085labelModeOne | read-only | optional | The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.3 | Columnrx085enumModeOne | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.4 | Columnrx085valueModeOne | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.5 | Columnrx085stateFlagModeOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.6 | Columnrx085labelWavelengthOne | read-only | optional | The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.7 | Columnrx085enumWavelengthOne | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.8 | Columnrx085valueWavelengthOne | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.9 | Columnrx085stateFlagWavelengthOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.10 | Columnrx085labelAttnSettingOne | read-only | optional | The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.11 | Columnrx085enumAttnSettingOne | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.12 | Columnrx085valueAttnSettingOne | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 0 to 60. Each increment represents 1/2 dB of attenuation from 0 to … |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.13 | Columnrx085stateFlagAttnSettingOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.14 | Columnrx085labelSwModeSettingOne | read-only | optional | The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.15 | Columnrx085enumSwModeSettingOne | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.16 | Columnrx085valueSwModeSettingOne | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.17 | Columnrx085stateFlagSwModeSettingOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.18 | Columnrx085labelSwModeThresholdOne | read-only | optional | The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.19 | Columnrx085enumSwModeThresholdOne | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.20 | Columnrx085valueSwModeThresholdOne | read-write | mandatory | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.21 | Columnrx085stateFlagSwModeThresholdOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.22 | Columnrx085labelModeTwo | read-only | optional | The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.23 | Columnrx085enumModeTwo | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.24 | Columnrx085valueModeTwo | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.25 | Columnrx085stateFlagModeTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.26 | Columnrx085labelWavelengthTwo | read-only | optional | The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.27 | Columnrx085enumWavelengthTwo | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.28 | Columnrx085valueWavelengthTwo | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.29 | Columnrx085stateFlagWavelengthTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.30 | Columnrx085labelAttnSettingTwo | read-only | optional | The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.31 | Columnrx085enumAttnSettingTwo | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.32 | Columnrx085valueAttnSettingTwo | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to … |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.33 | Columnrx085stateFlagAttnSettingTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.34 | Columnrx085labelSwModeSettingTwo | read-only | optional | The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.35 | Columnrx085enumSwModeSettingTwo | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.36 | Columnrx085valueSwModeSettingTwo | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.37 | Columnrx085stateFlagSwModeSettingTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.38 | Columnrx085labelSwModeThresholdTwo | read-only | optional | The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.39 | Columnrx085enumSwModeThresholdTwo | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.40 | Columnrx085valueSwModeThresholdTwo | read-write | mandatory | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.41 | Columnrx085stateFlagSwModeThresholdTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.42 | Columnrx085labelModeThree | read-only | optional | The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.43 | Columnrx085enumModeThree | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.44 | Columnrx085valueModeThree | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.45 | Columnrx085stateFlagModeThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.46 | Columnrx085labelWavelengthThree | read-only | optional | The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.47 | Columnrx085enumWavelengthThree | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.48 | Columnrx085valueWavelengthThree | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.49 | Columnrx085stateFlagWavelengthThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.50 | Columnrx085labelAttnSettingThree | read-only | optional | The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.51 | Columnrx085enumAttnSettingThree | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.52 | Columnrx085valueAttnSettingThree | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to … |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.53 | Columnrx085stateFlagAttnSettingThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.54 | Columnrx085labelSwModeSettingThree | read-only | optional | The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.55 | Columnrx085enumSwModeSettingThree | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.56 | Columnrx085valueSwModeSettingThree | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.57 | Columnrx085stateFlagSwModeSettingThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.58 | Columnrx085labelSwModeThresholdThree | read-only | optional | The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.59 | Columnrx085enumSwModeThresholdThree | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.60 | Columnrx085valueSwModeThresholdThree | read-write | mandatory | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.61 | Columnrx085stateFlagSwModeThresholdThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.62 | Columnrx085labelModeFour | read-only | optional | The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.63 | Columnrx085enumModeFour | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.64 | Columnrx085valueModeFour | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.65 | Columnrx085stateFlagModeFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.66 | Columnrx085labelWavelengthFour | read-only | optional | The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.67 | Columnrx085enumWavelengthFour | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.68 | Columnrx085valueWavelengthFour | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.69 | Columnrx085stateFlagWavelengthFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.70 | Columnrx085labelAttnSettingFour | read-only | optional | The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.71 | Columnrx085enumAttnSettingFour | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.72 | Columnrx085valueAttnSettingFour | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to … |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.73 | Columnrx085stateFlagAttnSettingFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.74 | Columnrx085labelSwModeSettingFour | read-only | optional | The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.75 | Columnrx085enumSwModeSettingFour | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.76 | Columnrx085valueSwModeSettingFour | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.77 | Columnrx085stateFlagSwModeSettingFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.78 | Columnrx085labelSwModeThresholdFour | read-only | optional | The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.79 | Columnrx085enumSwModeThresholdFour | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.80 | Columnrx085valueSwModeThresholdFour | read-write | mandatory | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.81 | Columnrx085stateFlagSwModeThresholdFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.82 | Columnrx085labelModuleConfig | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.83 | Columnrx085enumModuleConfig | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.84 | Columnrx085valueModuleConfig | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.85 | Columnrx085stateFlagModuleConfig | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.86 | Columnrx085labelRevertTime | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.87 | Columnrx085enumRevertTime | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.88 | Columnrx085valueRevertTime | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.89 | Columnrx085stateFlagRevertTime | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.90 | Columnrx085labelTestPointSelect | read-only | optional | The value of this object provides the label of the Test point Select Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.91 | Columnrx085enumTestPointSelect | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.92 | Columnrx085valueTestPointSelect | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.93 | Columnrx085stateFlagTestPointSelect | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.94 | Columnrx085labelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.95 | Columnrx085enumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.96 | Columnrx085valueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.3.2.97 | Columnrx085stateFlagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4 | Tablegx2Rx085BX4StatusTable | not-accessible | mandatory | This table contains gx2Rx085BX4 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.32.4 | NodetrapRx085BX4OpticalPower2Alarm | This trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.4.3 | Rowgx2Rx085BX4StatusEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.1 | Columngx2Rx085BX4StatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.2 | Columnrx085labelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.3 | Columnrx085valueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.4 | Columnrx085stateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.5 | Columnrx085labelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.6 | Columnrx085valueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.7 | Columnrx085stateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.8 | Columnrx085labelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.9 | Columnrx085valueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.10 | Columnrx085stateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.11 | Columnrx085labelAlarmDataCRC | read-only | optional | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.12 | Columnrx085valueAlarmDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.13 | Columnrx085stateflagAlarmDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.14 | Columnrx085labelCalibrationDataCRC | read-only | optional | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.15 | Columnrx085valueCalibrationDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.16 | Columnrx085stateflagCalibrationDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.17 | Columnrx085labelHW | read-only | optional | The value of this object provides the label of the Hardware Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.18 | Columnrx085valueHW | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.19 | Columnrx085stateflagHW | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.20 | Columnrx085labelOptSigOne | read-only | optional | The value of this object provides the label of the Optical Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.21 | Columnrx085valueOptSigOne | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.22 | Columnrx085stateflagOptSigOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.23 | Columnrx085labelOptSigTwo | read-only | optional | The value of this object provides the label of the Optical Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.24 | Columnrx085valueOptSigTwo | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.25 | Columnrx085stateflagOptSigTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.26 | Columnrx085labelOptSigThree | read-only | optional | The value of this object provides the label of the Optical Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.27 | Columnrx085valueOptSigThree | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.28 | Columnrx085stateflagOptSigThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.29 | Columnrx085labelOptSigFour | read-only | optional | The value of this object provides the label of the Optical Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.30 | Columnrx085valueOptSigFour | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.31 | Columnrx085stateflagOptSigFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.32 | Columnrx085labelBackupCable | read-only | optional | The value of this object provides the label of the Backup Cable Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.33 | Columnrx085valueBackupCable | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.32.4.3.34 | Columnrx085stateflagBackupCable | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.32.5 | Tablegx2Rx085BX4FactoryTable | not-accessible | mandatory | This table contains gx2Rx085BX4 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.32.5 | NodetrapRx085BX4OpticalPower3Alarm | This trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.5.4 | Rowgx2Rx085BX4FactoryEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.1 | Columngx2Rx085BX4FactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.2 | Columnrx085bootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.3 | Columnrx085bootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.4 | Columnrx085bank0CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.5 | Columnrx085bank1CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.6 | Columnrx085prgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.7 | Columnrx085factoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.8 | Columnrx085calculateCRC | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.9 | Columnrx085hourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.10 | Columnrx085flashPrgCntA | read-only | mandatory | This object provides the number of times the flash has been programmed on side A. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.11 | Columnrx085flashPrgCntB | read-only | mandatory | This object provides the number of times the flash has been programmed on side B. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.12 | Columnrx085fwRev0 | read-only | mandatory | This object provides the Revision of the firmware stores in bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.32.5.4.13 | Columnrx085fwRev1 | read-only | mandatory | This object provides the Revision of the firmware stores in bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.32.6 | NodetrapRx085BX4OpticalPower4Alarm | This trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.7 | NodetrapRx085BX4ModuleTemperatureAlarm | This trap is issued when the Rx085BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.32.8 | NodetrapRx085BX4FanCurrentAlarm | This trap is issued when the Rx085BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.9 | NodetrapRx085BX4Plus12CurrentAlarm | This trap is issued when the Rx085BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.10 | NodetrapRx085BX4Boot0Alarm | This trap is issued when the Rx085BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the th… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.11 | NodetrapRx085BX4Boot1Alarm | This trap is issued when the Rx085BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the th… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.12 | NodetrapRx085BX4FlashAlarm | This trap is issued when the Rx085BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains curren… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.13 | NodetrapRx085BX4AlarmDataCRCAlarm | This trap is issued when the Rx085BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of t… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.14 | NodetrapRx085BX4FactoryDataCRCAlarm | This trap is issued when the Rx085BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of … | ||
| 1.3.6.1.4.1.1166.6.1.2.32.15 | NodetrapRx085BX4CalDataCRCAlarm | This trap is issued when the Rx085BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.16 | NodetrapRx085BX4DefaultAlarm | This trap is issued when the Rx085BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this pa… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.17 | NodetrapRx085BX4Mode1Alarm | This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.18 | NodetrapRx085BX4Mode2Alarm | This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.19 | NodetrapRx085BX4Mode3Alarm | This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.20 | NodetrapRx085BX4Mode4Alarm | This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.21 | NodetrapRx085BX4Output1SwitchedAlarm | This trap is issued when the Rx085BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.22 | NodetrapRx085BX4Output2SwitchedAlarm | This trap is issued when the Rx085BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.23 | NodetrapRx085BX4Output3SwitchedAlarm | This trap is issued when the Rx085BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.24 | NodetrapRx085BX4Output4SwitchedAlarm | This trap is issued when the Rx085BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg… | ||
| 1.3.6.1.4.1.1166.6.1.2.32.25 | NodetrapRx085BX4RX1StatusAlarm | This trap is issued when receiver 1 of the Rx085BX4 Module output is turned on or off. | ||
| 1.3.6.1.4.1.1166.6.1.2.32.26 | NodetrapRx085BX4RX2StatusAlarm | This trap is issued when receiver 2 of the Rx085BX4 Module output is turned on or off. | ||
| 1.3.6.1.4.1.1166.6.1.2.32.27 | NodetrapRx085BX4RX3StatusAlarm | This trap is issued when receiver 3 of the Rx085BX4 Module output is turned on or off. | ||
| 1.3.6.1.4.1.1166.6.1.2.32.28 | NodetrapRx085BX4RX4StatusAlarm | This trap is issued when receiver 4 of the Rx085BX4 Module output is turned on or off. | ||
| 1.3.6.1.4.1.1166.6.1.2.32.29 | NodetrapRx085BX4BackupCableAlarm | This trap is issued when the slave receiver loses connection to the master receiver. | ||
| 1.3.6.1.4.1.1166.6.1.2.32.30 | NodetrapRx085BX4OptPwr1BadAlarm | This trap is issued when the receiver 1 optical power level falls below the user set switching threshold. | ||
| 1.3.6.1.4.1.1166.6.1.2.32.31 | NodetrapRx085BX4OptPwr2BadAlarm | This trap is issued when the receiver 2 optical power level falls below the user set switching threshold. | ||
| 1.3.6.1.4.1.1166.6.1.2.32.32 | NodetrapRx085BX4OptPwr3BadAlarm | This trap is issued when the receiver 3 optical power level falls below the user set switching threshold. | ||
| 1.3.6.1.4.1.1166.6.1.2.32.33 | NodetrapRx085BX4OptPwr4BadAlarm | This trap is issued when the receiver 4 optical power level falls below the user set switching threshold. |