MIB Viewer

OMNI-gx2Rx200BX4-MIB

264 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.29.1Nodegx2Rx200BX4Descriptor
1.3.6.1.4.1.1166.6.1.2.29.1NodetrapRx200BX4ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.29.2Tablegx2Rx200BX4AnalogTablenot-accessiblemandatoryThis table contains gx2Rx200BX4 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.29.2NodetrapRx200BX4ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.29.2.1Rowgx2Rx200BX4AnalogEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.29.2.1.1Columngx2Rx200BX4AnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.29.2.1.2Columnrx4labelOptPowerOneread-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.3Columnrx4uomOptPowerOneread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.4Columnrx4majorHighOptPowerOneread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.29.2.1.5Columnrx4majorLowOptPowerOneread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.29.2.1.6Columnrx4minorHighOptPowerOneread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.29.2.1.7Columnrx4minorLowOptPowerOneread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.29.2.1.8Columnrx4currentValueOptPowerOneread-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.9Columnrx4stateFlagOptPowerOneread-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.2.1.10Columnrx4minValueOptPowerOneread-onlymandatoryThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.11Columnrx4maxValueOptPowerOneread-onlymandatoryThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.12Columnrx4alarmStateOptPowerOneread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.13Columnrx4labelOptPowerTworead-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.14Columnrx4uomOptPowerTworead-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.15Columnrx4majorHighOptPowerTworead-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.29.2.1.16Columnrx4majorLowOptPowerTworead-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.29.2.1.17Columnrx4minorHighOptPowerTworead-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.29.2.1.18Columnrx4minorLowOptPowerTworead-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.29.2.1.19Columnrx4currentValueOptPowerTworead-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.20Columnrx4stateFlagOptPowerTworead-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.2.1.21Columnrx4minValueOptPowerTworead-onlymandatoryThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.22Columnrx4maxValueOptPowerTworead-onlymandatoryThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.23Columnrx4alarmStateOptPowerTworead-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.24Columnrx4labelOptPowerThreeread-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.25Columnrx4uomOptPowerThreeread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.26Columnrx4majorHighOptPowerThreeread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.29.2.1.27Columnrx4majorLowOptPowerThreeread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.29.2.1.28Columnrx4minorHighOptPowerThreeread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.29.2.1.29Columnrx4minorLowOptPowerThreeread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.29.2.1.30Columnrx4currentValueOptPowerThreeread-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.31Columnrx4stateFlagOptPowerThreeread-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.2.1.32Columnrx4minValueOptPowerThreeread-onlymandatoryThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.33Columnrx4maxValueOptPowerThreeread-onlymandatoryThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.34Columnrx4alarmStateOptPowerThreeread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.35Columnrx4labelOptPowerFourread-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.36Columnrx4uomOptPowerFourread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.37Columnrx4majorHighOptPowerFourread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.29.2.1.38Columnrx4majorLowOptPowerFourread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.29.2.1.39Columnrx4minorHighOptPowerFourread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.29.2.1.40Columnrx4minorLowOptPowerFourread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.29.2.1.41Columnrx4currentValueOptPowerFourread-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.42Columnrx4stateFlagOptPowerFourread-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.2.1.43Columnrx4minValueOptPowerFourread-onlymandatoryThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.44Columnrx4maxValueOptPowerFourread-onlymandatoryThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.45Columnrx4alarmStateOptPowerFourread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.46Columnrx4labelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.47Columnrx4uomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.48Columnrx4majorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.29.2.1.49Columnrx4majorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.29.2.1.50Columnrx4minorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.29.2.1.51Columnrx4minorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.29.2.1.52Columnrx4currentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.29.2.1.53Columnrx4stateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.2.1.54Columnrx4minValueModTempread-onlymandatoryThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.29.2.1.55Columnrx4maxValueModTempread-onlymandatoryThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.29.2.1.56Columnrx4alarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.57Columnrx4labelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.58Columnrx4uomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.59Columnrx4majorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.29.2.1.60Columnrx4majorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.29.2.1.61Columnrx4minorHighFanCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.29.2.1.62Columnrx4minorLowFanCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.29.2.1.63Columnrx4currentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.29.2.1.64Columnrx4stateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.2.1.65Columnrx4minValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.29.2.1.66Columnrx4maxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.29.2.1.67Columnrx4alarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.68Columnrx4label12Voltread-onlyoptionalThe value of this object provides the label of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.69Columnrx4uom12Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.2.1.70Columnrx4majorHigh12Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.29.2.1.71Columnrx4majorLow12Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.29.2.1.72Columnrx4minorHigh12Voltread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.29.2.1.73Columnrx4minorLow12Voltread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.29.2.1.74Columnrx4currentValue12Voltread-onlymandatoryThe value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.75Columnrx4stateFlag12Voltread-onlymandatoryThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.2.1.76Columnrx4minValue12Voltread-onlymandatoryThe value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.77Columnrx4maxValue12Voltread-onlymandatoryThe value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.29.2.1.78Columnrx4alarmState12Voltread-onlymandatoryThe value of this object provides the curent alarm state of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.29.3Tablegx2Rx200BX4DigitalTablenot-accessiblemandatoryThis table contains gx2Rx200BX4 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.29.3NodetrapRx200BX4OpticalPower1AlarmThis trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the…
1.3.6.1.4.1.1166.6.1.2.29.3.2Rowgx2Rx200BX4DigitalEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.29.3.2.1Columngx2Rx200BX4DigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.29.3.2.2Columnrx4labelModeOneread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.3Columnrx4enumModeOneread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.4Columnrx4valueModeOneread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.5Columnrx4stateFlagModeOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.6Columnrx4labelWavelengthOneread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.7Columnrx4enumWavelengthOneread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.8Columnrx4valueWavelengthOneread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.9Columnrx4stateFlagWavelengthOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.10Columnrx4labelAttnSettingOneread-onlyoptionalThe value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.11Columnrx4enumAttnSettingOneread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.12Columnrx4valueAttnSettingOneread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to …
1.3.6.1.4.1.1166.6.1.2.29.3.2.13Columnrx4stateFlagAttnSettingOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.14Columnrx4labelSwModeSettingOneread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.15Columnrx4enumSwModeSettingOneread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.16Columnrx4valueSwModeSettingOneread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.17Columnrx4stateFlagSwModeSettingOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.18Columnrx4labelSwModeThresholdOneread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.19Columnrx4enumSwModeThresholdOneread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.20Columnrx4valueSwModeThresholdOneread-writemandatoryThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1…
1.3.6.1.4.1.1166.6.1.2.29.3.2.21Columnrx4stateFlagSwModeThresholdOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.22Columnrx4labelModeTworead-onlyoptionalThe value of this object provides the label of the Rx200BX4's Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.23Columnrx4enumModeTworead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.24Columnrx4valueModeTworead-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.25Columnrx4stateFlagModeTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.26Columnrx4labelWavelengthTworead-onlyoptionalThe value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.27Columnrx4enumWavelengthTworead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.28Columnrx4valueWavelengthTworead-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.29Columnrx4stateFlagWavelengthTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.30Columnrx4labelAttnSettingTworead-onlyoptionalThe value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.31Columnrx4enumAttnSettingTworead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.32Columnrx4valueAttnSettingTworead-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to …
1.3.6.1.4.1.1166.6.1.2.29.3.2.33Columnrx4stateFlagAttnSettingTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.34Columnrx4labelSwModeSettingTworead-onlyoptionalThe value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.35Columnrx4enumSwModeSettingTworead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.36Columnrx4valueSwModeSettingTworead-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.37Columnrx4stateFlagSwModeSettingTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.38Columnrx4labelSwModeThresholdTworead-onlyoptionalThe value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.39Columnrx4enumSwModeThresholdTworead-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.40Columnrx4valueSwModeThresholdTworead-writemandatoryThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1…
1.3.6.1.4.1.1166.6.1.2.29.3.2.41Columnrx4stateFlagSwModeThresholdTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.42Columnrx4labelModeThreeread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.43Columnrx4enumModeThreeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.44Columnrx4valueModeThreeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.45Columnrx4stateFlagModeThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.46Columnrx4labelWavelengthThreeread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.47Columnrx4enumWavelengthThreeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.48Columnrx4valueWavelengthThreeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.49Columnrx4stateFlagWavelengthThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.50Columnrx4labelAttnSettingThreeread-onlyoptionalThe value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.51Columnrx4enumAttnSettingThreeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.52Columnrx4valueAttnSettingThreeread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to …
1.3.6.1.4.1.1166.6.1.2.29.3.2.53Columnrx4stateFlagAttnSettingThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.54Columnrx4labelSwModeSettingThreeread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.55Columnrx4enumSwModeSettingThreeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.56Columnrx4valueSwModeSettingThreeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.57Columnrx4stateFlagSwModeSettingThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.58Columnrx4labelSwModeThresholdThreeread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.59Columnrx4enumSwModeThresholdThreeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.60Columnrx4valueSwModeThresholdThreeread-writemandatoryThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1…
1.3.6.1.4.1.1166.6.1.2.29.3.2.61Columnrx4stateFlagSwModeThresholdThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.62Columnrx4labelModeFourread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.63Columnrx4enumModeFourread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.64Columnrx4valueModeFourread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.65Columnrx4stateFlagModeFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.66Columnrx4labelWavelengthFourread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.67Columnrx4enumWavelengthFourread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.68Columnrx4valueWavelengthFourread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.69Columnrx4stateFlagWavelengthFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.70Columnrx4labelAttnSettingFourread-onlyoptionalThe value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.71Columnrx4enumAttnSettingFourread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.72Columnrx4valueAttnSettingFourread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to …
1.3.6.1.4.1.1166.6.1.2.29.3.2.73Columnrx4stateFlagAttnSettingFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.74Columnrx4labelSwModeSettingFourread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.75Columnrx4enumSwModeSettingFourread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.76Columnrx4valueSwModeSettingFourread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.77Columnrx4stateFlagSwModeSettingFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.78Columnrx4labelSwModeThresholdFourread-onlyoptionalThe value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.79Columnrx4enumSwModeThresholdFourread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.80Columnrx4valueSwModeThresholdFourread-writemandatoryThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1…
1.3.6.1.4.1.1166.6.1.2.29.3.2.81Columnrx4stateFlagSwModeThresholdFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.82Columnrx4labelModuleConfigread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.83Columnrx4enumModuleConfigread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.84Columnrx4valueModuleConfigread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.85Columnrx4stateFlagModuleConfigread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.86Columnrx4labelRevertTimeread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.87Columnrx4enumRevertTimeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.88Columnrx4valueRevertTimeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.89Columnrx4stateFlagRevertTimeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.90Columnrx4labelTestPointSelectread-onlyoptionalThe value of this object provides the label of the Test point Select Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.91Columnrx4enumTestPointSelectread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.92Columnrx4valueTestPointSelectread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.93Columnrx4stateFlagTestPointSelectread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.3.2.94Columnrx4labelFactoryDefaultread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.95Columnrx4enumFactoryDefaultread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.29.3.2.96Columnrx4valueFactoryDefaultread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.29.3.2.97Columnrx4stateFlagFactoryDefaultread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4Tablegx2Rx200BX4StatusTablenot-accessiblemandatoryThis table contains gx2Rx200BX4 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.29.4NodetrapRx200BX4OpticalPower2AlarmThis trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the…
1.3.6.1.4.1.1166.6.1.2.29.4.3Rowgx2Rx200BX4StatusEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.29.4.3.1Columngx2Rx200BX4StatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.29.4.3.2Columnrx4labelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.3Columnrx4valueBootread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.4Columnrx4stateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4.3.5Columnrx4labelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.6Columnrx4valueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.7Columnrx4stateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4.3.8Columnrx4labelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.9Columnrx4valueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.10Columnrx4stateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4.3.11Columnrx4labelAlarmDataCRCread-onlyoptionalThe value of this object provides the label of the Alarm Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.12Columnrx4valueAlarmDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.13Columnrx4stateflagAlarmDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4.3.14Columnrx4labelCalibrationDataCRCread-onlyoptionalThe value of this object provides the label of the Calibration Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.15Columnrx4valueCalibrationDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.16Columnrx4stateflagCalibrationDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4.3.17Columnrx4labelHWread-onlyoptionalThe value of this object provides the label of the Hardware Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.18Columnrx4valueHWread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.19Columnrx4stateflagHWread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4.3.20Columnrx4labelOptSigOneread-onlyoptionalThe value of this object provides the label of the Optical Signal Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.21Columnrx4valueOptSigOneread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.22Columnrx4stateflagOptSigOneread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4.3.23Columnrx4labelOptSigTworead-onlyoptionalThe value of this object provides the label of the Optical Signal Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.24Columnrx4valueOptSigTworead-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.25Columnrx4stateflagOptSigTworead-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4.3.26Columnrx4labelOptSigThreeread-onlyoptionalThe value of this object provides the label of the Optical Signal Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.27Columnrx4valueOptSigThreeread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.28Columnrx4stateflagOptSigThreeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4.3.29Columnrx4labelOptSigFourread-onlyoptionalThe value of this object provides the label of the Optical Signal Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.30Columnrx4valueOptSigFourread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.31Columnrx4stateflagOptSigFourread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.4.3.32Columnrx4labelBackupCableread-onlyoptionalThe value of this object provides the label of the Backup Cable Status parameter.
1.3.6.1.4.1.1166.6.1.2.29.4.3.33Columnrx4valueBackupCableread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.29.4.3.34Columnrx4stateflagBackupCableread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.29.5Tablegx2Rx200BX4FactoryTablenot-accessiblemandatoryThis table contains gx2Rx200BX4 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.29.5NodetrapRx200BX4OpticalPower3AlarmThis trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the…
1.3.6.1.4.1.1166.6.1.2.29.5.4Rowgx2Rx200BX4FactoryEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.29.5.4.1Columngx2Rx200BX4FactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.29.5.4.2Columnrx4bootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.29.5.4.3Columnrx4bootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.29.5.4.4Columnrx4bank0CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.29.5.4.5Columnrx4bank1CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.29.5.4.6Columnrx4prgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.29.5.4.7Columnrx4factoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.29.5.4.8Columnrx4calculateCRCread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.29.5.4.9Columnrx4hourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.29.5.4.10Columnrx4flashPrgCntAread-onlymandatoryThis object provides the number of times the flash has been programmed on side A.
1.3.6.1.4.1.1166.6.1.2.29.5.4.11Columnrx4flashPrgCntBread-onlymandatoryThis object provides the number of times the flash has been programmed on side B.
1.3.6.1.4.1.1166.6.1.2.29.5.4.12Columnrx4fwRev0read-onlymandatoryThis object provides the Revision of the firmware stores in bank 0.
1.3.6.1.4.1.1166.6.1.2.29.5.4.13Columnrx4fwRev1read-onlymandatoryThis object provides the Revision of the firmware stores in bank 1.
1.3.6.1.4.1.1166.6.1.2.29.6NodetrapRx200BX4OpticalPower4AlarmThis trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the…
1.3.6.1.4.1.1166.6.1.2.29.7NodetrapRx200BX4ModuleTemperatureAlarmThis trap is issued when the Rx200BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.29.8NodetrapRx200BX4FanCurrentAlarmThis trap is issued when the Rx200BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this…
1.3.6.1.4.1.1166.6.1.2.29.9NodetrapRx200BX4Plus12CurrentAlarmThis trap is issued when the Rx200BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading…
1.3.6.1.4.1.1166.6.1.2.29.10NodetrapRx200BX4Boot0AlarmThis trap is issued when the Rx200BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the th…
1.3.6.1.4.1.1166.6.1.2.29.11NodetrapRx200BX4Boot1AlarmThis trap is issued when the Rx200BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the th…
1.3.6.1.4.1.1166.6.1.2.29.12NodetrapRx200BX4FlashAlarmThis trap is issued when the Rx200BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains curren…
1.3.6.1.4.1.1166.6.1.2.29.13NodetrapRx200BX4AlarmDataCRCAlarmThis trap is issued when the Rx200BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of t…
1.3.6.1.4.1.1166.6.1.2.29.14NodetrapRx200BX4FactoryDataCRCAlarmThis trap is issued when the Rx200BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of …
1.3.6.1.4.1.1166.6.1.2.29.15NodetrapRx200BX4CalDataCRCAlarmThis trap is issued when the Rx200BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading…
1.3.6.1.4.1.1166.6.1.2.29.16NodetrapRx200BX4DefaultAlarmThis trap is issued when the Rx200BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this pa…
1.3.6.1.4.1.1166.6.1.2.29.17NodetrapRx200BX4Mode1AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren…
1.3.6.1.4.1.1166.6.1.2.29.18NodetrapRx200BX4Mode2AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren…
1.3.6.1.4.1.1166.6.1.2.29.19NodetrapRx200BX4Mode3AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren…
1.3.6.1.4.1.1166.6.1.2.29.20NodetrapRx200BX4Mode4AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren…
1.3.6.1.4.1.1166.6.1.2.29.21NodetrapRx200BX4Output1SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg…
1.3.6.1.4.1.1166.6.1.2.29.22NodetrapRx200BX4Output2SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg…
1.3.6.1.4.1.1166.6.1.2.29.23NodetrapRx200BX4Output3SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg…
1.3.6.1.4.1.1166.6.1.2.29.24NodetrapRx200BX4Output4SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg…
1.3.6.1.4.1.1166.6.1.2.29.25NodetrapRx200BX4RX1StatusAlarmThis trap is issued when receiver 1 of the Rx200BX4 Module output is turned on or off.
1.3.6.1.4.1.1166.6.1.2.29.26NodetrapRx200BX4RX2StatusAlarmThis trap is issued when receiver 2 of the Rx200BX4 Module output is turned on or off.
1.3.6.1.4.1.1166.6.1.2.29.27NodetrapRx200BX4RX3StatusAlarmThis trap is issued when receiver 3 of the Rx200BX4 Module output is turned on or off.
1.3.6.1.4.1.1166.6.1.2.29.28NodetrapRx200BX4RX4StatusAlarmThis trap is issued when receiver 4 of the Rx200BX4 Module output is turned on or off.
1.3.6.1.4.1.1166.6.1.2.29.29NodetrapRx200BX4BackupCableAlarmThis trap is issued when the slave receiver loses connection to the master receiver.
1.3.6.1.4.1.1166.6.1.2.29.30NodetrapRx200BX4OptPwr1BadAlarmThis trap is issued when the receiver 1 optical power level falls below the user set switching threshold.
1.3.6.1.4.1.1166.6.1.2.29.31NodetrapRx200BX4OptPwr2BadAlarmThis trap is issued when the receiver 2 optical power level falls below the user set switching threshold.
1.3.6.1.4.1.1166.6.1.2.29.32NodetrapRx200BX4OptPwr3BadAlarmThis trap is issued when the receiver 3 optical power level falls below the user set switching threshold.
1.3.6.1.4.1.1166.6.1.2.29.33NodetrapRx200BX4OptPwr4BadAlarmThis trap is issued when the receiver 4 optical power level falls below the user set switching threshold.