OMNI-gx2Rx200BX4-MIB
264 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.29.1 | Nodegx2Rx200BX4Descriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.29.1 | NodetrapRx200BX4ConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.2 | Tablegx2Rx200BX4AnalogTable | not-accessible | mandatory | This table contains gx2Rx200BX4 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.29.2 | NodetrapRx200BX4ConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.29.2.1 | Rowgx2Rx200BX4AnalogEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.1 | Columngx2Rx200BX4AnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.2 | Columnrx4labelOptPowerOne | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.3 | Columnrx4uomOptPowerOne | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.4 | Columnrx4majorHighOptPowerOne | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.5 | Columnrx4majorLowOptPowerOne | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.6 | Columnrx4minorHighOptPowerOne | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.7 | Columnrx4minorLowOptPowerOne | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.8 | Columnrx4currentValueOptPowerOne | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.9 | Columnrx4stateFlagOptPowerOne | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.10 | Columnrx4minValueOptPowerOne | read-only | mandatory | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.11 | Columnrx4maxValueOptPowerOne | read-only | mandatory | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.12 | Columnrx4alarmStateOptPowerOne | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.13 | Columnrx4labelOptPowerTwo | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.14 | Columnrx4uomOptPowerTwo | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.15 | Columnrx4majorHighOptPowerTwo | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.16 | Columnrx4majorLowOptPowerTwo | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.17 | Columnrx4minorHighOptPowerTwo | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.18 | Columnrx4minorLowOptPowerTwo | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.19 | Columnrx4currentValueOptPowerTwo | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.20 | Columnrx4stateFlagOptPowerTwo | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.21 | Columnrx4minValueOptPowerTwo | read-only | mandatory | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.22 | Columnrx4maxValueOptPowerTwo | read-only | mandatory | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.23 | Columnrx4alarmStateOptPowerTwo | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.24 | Columnrx4labelOptPowerThree | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.25 | Columnrx4uomOptPowerThree | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.26 | Columnrx4majorHighOptPowerThree | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.27 | Columnrx4majorLowOptPowerThree | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.28 | Columnrx4minorHighOptPowerThree | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.29 | Columnrx4minorLowOptPowerThree | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.30 | Columnrx4currentValueOptPowerThree | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.31 | Columnrx4stateFlagOptPowerThree | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.32 | Columnrx4minValueOptPowerThree | read-only | mandatory | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.33 | Columnrx4maxValueOptPowerThree | read-only | mandatory | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.34 | Columnrx4alarmStateOptPowerThree | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.35 | Columnrx4labelOptPowerFour | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.36 | Columnrx4uomOptPowerFour | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.37 | Columnrx4majorHighOptPowerFour | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.38 | Columnrx4majorLowOptPowerFour | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.39 | Columnrx4minorHighOptPowerFour | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.40 | Columnrx4minorLowOptPowerFour | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.41 | Columnrx4currentValueOptPowerFour | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.42 | Columnrx4stateFlagOptPowerFour | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.43 | Columnrx4minValueOptPowerFour | read-only | mandatory | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.44 | Columnrx4maxValueOptPowerFour | read-only | mandatory | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.45 | Columnrx4alarmStateOptPowerFour | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.46 | Columnrx4labelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.47 | Columnrx4uomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.48 | Columnrx4majorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.49 | Columnrx4majorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.50 | Columnrx4minorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.51 | Columnrx4minorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.52 | Columnrx4currentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.53 | Columnrx4stateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.54 | Columnrx4minValueModTemp | read-only | mandatory | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.55 | Columnrx4maxValueModTemp | read-only | mandatory | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.56 | Columnrx4alarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.57 | Columnrx4labelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.58 | Columnrx4uomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.59 | Columnrx4majorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.60 | Columnrx4majorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.61 | Columnrx4minorHighFanCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.62 | Columnrx4minorLowFanCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.63 | Columnrx4currentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.64 | Columnrx4stateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.65 | Columnrx4minValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.66 | Columnrx4maxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.67 | Columnrx4alarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.68 | Columnrx4label12Volt | read-only | optional | The value of this object provides the label of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.69 | Columnrx4uom12Volt | read-only | optional | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.70 | Columnrx4majorHigh12Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.71 | Columnrx4majorLow12Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.72 | Columnrx4minorHigh12Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.73 | Columnrx4minorLow12Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.74 | Columnrx4currentValue12Volt | read-only | mandatory | The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.75 | Columnrx4stateFlag12Volt | read-only | mandatory | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.76 | Columnrx4minValue12Volt | read-only | mandatory | The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.77 | Columnrx4maxValue12Volt | read-only | mandatory | The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.29.2.1.78 | Columnrx4alarmState12Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3 | Tablegx2Rx200BX4DigitalTable | not-accessible | mandatory | This table contains gx2Rx200BX4 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.29.3 | NodetrapRx200BX4OpticalPower1Alarm | This trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.3.2 | Rowgx2Rx200BX4DigitalEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.1 | Columngx2Rx200BX4DigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.2 | Columnrx4labelModeOne | read-only | optional | The value of this object provides the label of the Rx200BX4's Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.3 | Columnrx4enumModeOne | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.4 | Columnrx4valueModeOne | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.5 | Columnrx4stateFlagModeOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.6 | Columnrx4labelWavelengthOne | read-only | optional | The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.7 | Columnrx4enumWavelengthOne | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.8 | Columnrx4valueWavelengthOne | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.9 | Columnrx4stateFlagWavelengthOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.10 | Columnrx4labelAttnSettingOne | read-only | optional | The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.11 | Columnrx4enumAttnSettingOne | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.12 | Columnrx4valueAttnSettingOne | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to … |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.13 | Columnrx4stateFlagAttnSettingOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.14 | Columnrx4labelSwModeSettingOne | read-only | optional | The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.15 | Columnrx4enumSwModeSettingOne | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.16 | Columnrx4valueSwModeSettingOne | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.17 | Columnrx4stateFlagSwModeSettingOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.18 | Columnrx4labelSwModeThresholdOne | read-only | optional | The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.19 | Columnrx4enumSwModeThresholdOne | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.20 | Columnrx4valueSwModeThresholdOne | read-write | mandatory | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.21 | Columnrx4stateFlagSwModeThresholdOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.22 | Columnrx4labelModeTwo | read-only | optional | The value of this object provides the label of the Rx200BX4's Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.23 | Columnrx4enumModeTwo | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.24 | Columnrx4valueModeTwo | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.25 | Columnrx4stateFlagModeTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.26 | Columnrx4labelWavelengthTwo | read-only | optional | The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.27 | Columnrx4enumWavelengthTwo | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.28 | Columnrx4valueWavelengthTwo | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.29 | Columnrx4stateFlagWavelengthTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.30 | Columnrx4labelAttnSettingTwo | read-only | optional | The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.31 | Columnrx4enumAttnSettingTwo | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.32 | Columnrx4valueAttnSettingTwo | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to … |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.33 | Columnrx4stateFlagAttnSettingTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.34 | Columnrx4labelSwModeSettingTwo | read-only | optional | The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.35 | Columnrx4enumSwModeSettingTwo | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.36 | Columnrx4valueSwModeSettingTwo | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.37 | Columnrx4stateFlagSwModeSettingTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.38 | Columnrx4labelSwModeThresholdTwo | read-only | optional | The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.39 | Columnrx4enumSwModeThresholdTwo | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.40 | Columnrx4valueSwModeThresholdTwo | read-write | mandatory | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.41 | Columnrx4stateFlagSwModeThresholdTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.42 | Columnrx4labelModeThree | read-only | optional | The value of this object provides the label of the Rx200BX4's Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.43 | Columnrx4enumModeThree | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.44 | Columnrx4valueModeThree | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.45 | Columnrx4stateFlagModeThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.46 | Columnrx4labelWavelengthThree | read-only | optional | The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.47 | Columnrx4enumWavelengthThree | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.48 | Columnrx4valueWavelengthThree | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.49 | Columnrx4stateFlagWavelengthThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.50 | Columnrx4labelAttnSettingThree | read-only | optional | The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.51 | Columnrx4enumAttnSettingThree | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.52 | Columnrx4valueAttnSettingThree | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to … |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.53 | Columnrx4stateFlagAttnSettingThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.54 | Columnrx4labelSwModeSettingThree | read-only | optional | The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.55 | Columnrx4enumSwModeSettingThree | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.56 | Columnrx4valueSwModeSettingThree | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.57 | Columnrx4stateFlagSwModeSettingThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.58 | Columnrx4labelSwModeThresholdThree | read-only | optional | The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.59 | Columnrx4enumSwModeThresholdThree | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.60 | Columnrx4valueSwModeThresholdThree | read-write | mandatory | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.61 | Columnrx4stateFlagSwModeThresholdThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.62 | Columnrx4labelModeFour | read-only | optional | The value of this object provides the label of the Rx200BX4's Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.63 | Columnrx4enumModeFour | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.64 | Columnrx4valueModeFour | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.65 | Columnrx4stateFlagModeFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.66 | Columnrx4labelWavelengthFour | read-only | optional | The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.67 | Columnrx4enumWavelengthFour | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.68 | Columnrx4valueWavelengthFour | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.69 | Columnrx4stateFlagWavelengthFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.70 | Columnrx4labelAttnSettingFour | read-only | optional | The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.71 | Columnrx4enumAttnSettingFour | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.72 | Columnrx4valueAttnSettingFour | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to … |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.73 | Columnrx4stateFlagAttnSettingFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.74 | Columnrx4labelSwModeSettingFour | read-only | optional | The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.75 | Columnrx4enumSwModeSettingFour | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.76 | Columnrx4valueSwModeSettingFour | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.77 | Columnrx4stateFlagSwModeSettingFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.78 | Columnrx4labelSwModeThresholdFour | read-only | optional | The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.79 | Columnrx4enumSwModeThresholdFour | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.80 | Columnrx4valueSwModeThresholdFour | read-write | mandatory | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -1… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.81 | Columnrx4stateFlagSwModeThresholdFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.82 | Columnrx4labelModuleConfig | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.83 | Columnrx4enumModuleConfig | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.84 | Columnrx4valueModuleConfig | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.85 | Columnrx4stateFlagModuleConfig | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.86 | Columnrx4labelRevertTime | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.87 | Columnrx4enumRevertTime | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.88 | Columnrx4valueRevertTime | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.89 | Columnrx4stateFlagRevertTime | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.90 | Columnrx4labelTestPointSelect | read-only | optional | The value of this object provides the label of the Test point Select Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.91 | Columnrx4enumTestPointSelect | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.92 | Columnrx4valueTestPointSelect | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.93 | Columnrx4stateFlagTestPointSelect | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.94 | Columnrx4labelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.95 | Columnrx4enumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.96 | Columnrx4valueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.3.2.97 | Columnrx4stateFlagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4 | Tablegx2Rx200BX4StatusTable | not-accessible | mandatory | This table contains gx2Rx200BX4 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.29.4 | NodetrapRx200BX4OpticalPower2Alarm | This trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.4.3 | Rowgx2Rx200BX4StatusEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.1 | Columngx2Rx200BX4StatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.2 | Columnrx4labelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.3 | Columnrx4valueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.4 | Columnrx4stateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.5 | Columnrx4labelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.6 | Columnrx4valueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.7 | Columnrx4stateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.8 | Columnrx4labelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.9 | Columnrx4valueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.10 | Columnrx4stateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.11 | Columnrx4labelAlarmDataCRC | read-only | optional | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.12 | Columnrx4valueAlarmDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.13 | Columnrx4stateflagAlarmDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.14 | Columnrx4labelCalibrationDataCRC | read-only | optional | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.15 | Columnrx4valueCalibrationDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.16 | Columnrx4stateflagCalibrationDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.17 | Columnrx4labelHW | read-only | optional | The value of this object provides the label of the Hardware Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.18 | Columnrx4valueHW | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.19 | Columnrx4stateflagHW | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.20 | Columnrx4labelOptSigOne | read-only | optional | The value of this object provides the label of the Optical Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.21 | Columnrx4valueOptSigOne | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.22 | Columnrx4stateflagOptSigOne | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.23 | Columnrx4labelOptSigTwo | read-only | optional | The value of this object provides the label of the Optical Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.24 | Columnrx4valueOptSigTwo | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.25 | Columnrx4stateflagOptSigTwo | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.26 | Columnrx4labelOptSigThree | read-only | optional | The value of this object provides the label of the Optical Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.27 | Columnrx4valueOptSigThree | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.28 | Columnrx4stateflagOptSigThree | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.29 | Columnrx4labelOptSigFour | read-only | optional | The value of this object provides the label of the Optical Signal Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.30 | Columnrx4valueOptSigFour | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.31 | Columnrx4stateflagOptSigFour | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.32 | Columnrx4labelBackupCable | read-only | optional | The value of this object provides the label of the Backup Cable Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.33 | Columnrx4valueBackupCable | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.29.4.3.34 | Columnrx4stateflagBackupCable | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.29.5 | Tablegx2Rx200BX4FactoryTable | not-accessible | mandatory | This table contains gx2Rx200BX4 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.29.5 | NodetrapRx200BX4OpticalPower3Alarm | This trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.5.4 | Rowgx2Rx200BX4FactoryEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.1 | Columngx2Rx200BX4FactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.2 | Columnrx4bootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.3 | Columnrx4bootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.4 | Columnrx4bank0CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.5 | Columnrx4bank1CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.6 | Columnrx4prgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.7 | Columnrx4factoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.8 | Columnrx4calculateCRC | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.9 | Columnrx4hourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.10 | Columnrx4flashPrgCntA | read-only | mandatory | This object provides the number of times the flash has been programmed on side A. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.11 | Columnrx4flashPrgCntB | read-only | mandatory | This object provides the number of times the flash has been programmed on side B. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.12 | Columnrx4fwRev0 | read-only | mandatory | This object provides the Revision of the firmware stores in bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.29.5.4.13 | Columnrx4fwRev1 | read-only | mandatory | This object provides the Revision of the firmware stores in bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.29.6 | NodetrapRx200BX4OpticalPower4Alarm | This trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.7 | NodetrapRx200BX4ModuleTemperatureAlarm | This trap is issued when the Rx200BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.29.8 | NodetrapRx200BX4FanCurrentAlarm | This trap is issued when the Rx200BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.9 | NodetrapRx200BX4Plus12CurrentAlarm | This trap is issued when the Rx200BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.10 | NodetrapRx200BX4Boot0Alarm | This trap is issued when the Rx200BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the th… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.11 | NodetrapRx200BX4Boot1Alarm | This trap is issued when the Rx200BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the th… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.12 | NodetrapRx200BX4FlashAlarm | This trap is issued when the Rx200BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains curren… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.13 | NodetrapRx200BX4AlarmDataCRCAlarm | This trap is issued when the Rx200BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of t… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.14 | NodetrapRx200BX4FactoryDataCRCAlarm | This trap is issued when the Rx200BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of … | ||
| 1.3.6.1.4.1.1166.6.1.2.29.15 | NodetrapRx200BX4CalDataCRCAlarm | This trap is issued when the Rx200BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.16 | NodetrapRx200BX4DefaultAlarm | This trap is issued when the Rx200BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this pa… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.17 | NodetrapRx200BX4Mode1Alarm | This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.18 | NodetrapRx200BX4Mode2Alarm | This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.19 | NodetrapRx200BX4Mode3Alarm | This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.20 | NodetrapRx200BX4Mode4Alarm | This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains curren… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.21 | NodetrapRx200BX4Output1SwitchedAlarm | This trap is issued when the Rx200BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.22 | NodetrapRx200BX4Output2SwitchedAlarm | This trap is issued when the Rx200BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.23 | NodetrapRx200BX4Output3SwitchedAlarm | This trap is issued when the Rx200BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.24 | NodetrapRx200BX4Output4SwitchedAlarm | This trap is issued when the Rx200BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteg… | ||
| 1.3.6.1.4.1.1166.6.1.2.29.25 | NodetrapRx200BX4RX1StatusAlarm | This trap is issued when receiver 1 of the Rx200BX4 Module output is turned on or off. | ||
| 1.3.6.1.4.1.1166.6.1.2.29.26 | NodetrapRx200BX4RX2StatusAlarm | This trap is issued when receiver 2 of the Rx200BX4 Module output is turned on or off. | ||
| 1.3.6.1.4.1.1166.6.1.2.29.27 | NodetrapRx200BX4RX3StatusAlarm | This trap is issued when receiver 3 of the Rx200BX4 Module output is turned on or off. | ||
| 1.3.6.1.4.1.1166.6.1.2.29.28 | NodetrapRx200BX4RX4StatusAlarm | This trap is issued when receiver 4 of the Rx200BX4 Module output is turned on or off. | ||
| 1.3.6.1.4.1.1166.6.1.2.29.29 | NodetrapRx200BX4BackupCableAlarm | This trap is issued when the slave receiver loses connection to the master receiver. | ||
| 1.3.6.1.4.1.1166.6.1.2.29.30 | NodetrapRx200BX4OptPwr1BadAlarm | This trap is issued when the receiver 1 optical power level falls below the user set switching threshold. | ||
| 1.3.6.1.4.1.1166.6.1.2.29.31 | NodetrapRx200BX4OptPwr2BadAlarm | This trap is issued when the receiver 2 optical power level falls below the user set switching threshold. | ||
| 1.3.6.1.4.1.1166.6.1.2.29.32 | NodetrapRx200BX4OptPwr3BadAlarm | This trap is issued when the receiver 3 optical power level falls below the user set switching threshold. | ||
| 1.3.6.1.4.1.1166.6.1.2.29.33 | NodetrapRx200BX4OptPwr4BadAlarm | This trap is issued when the receiver 4 optical power level falls below the user set switching threshold. |