OMNI-gx2drr3x-MIB
160 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.13.1 | Nodegx2drr3xDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.13.1 | NodetrapdrrConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.13.2 | Tablegx2drr3xAnalogTable | not-accessible | mandatory | This table contains gx2drr3x specific analog parameters with nominal,limits and current values. |
| 1.3.6.1.4.1.1166.6.1.2.13.2 | NodetrapdrrConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.13.2.1 | Rowgx2drr3xAnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.1 | Columngx2drr3xAnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.2 | ColumndrrlabelRFAAttenuation | read-only | optional | The value of this object provides the label of the RF Channel A Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.3 | ColumndrruomRFAAttenuation | read-only | optional | The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.4 | ColumndrrmajorHighRFAAttenuation | read-only | mandatory | The value of this object provides the Major High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.5 | ColumndrrmajorLowRFAAttenuation | read-only | mandatory | The value of this object provides the Major Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module an… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.6 | ColumndrrminorHighRFAAttenuation | read-only | mandatory | The value of this object provides the Minor High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.7 | ColumndrrminorLowRFAAttenuation | read-only | mandatory | The value of this object provides the Minor Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module an… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.8 | ColumndrrcurrentValueRFAAttenuation | read-write | mandatory | The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.9 | ColumndrrstateFlagRFAAttenuation | read-only | mandatory | The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.10 | ColumndrrminValueRFAAttenuation | read-only | mandatory | The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.11 | ColumndrrmaxValueRFAAttenuation | read-only | mandatory | The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.12 | ColumndrralarmStateRFAAttenuation | read-only | mandatory | The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.13 | ColumndrrlabelRFBAttenuation | read-only | optional | The value of this object provides the label of the RF Channel B Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.14 | ColumndrruomRFBAttenuation | read-only | optional | The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.15 | ColumndrrmajorHighRFBAttenuation | read-only | mandatory | The value of this object provides the Major High alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.16 | ColumndrrmajorLowRFBAttenuation | read-only | mandatory | The value of this object provides the Major Low alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module an… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.17 | ColumndrrminorHighRFBAttenuation | read-only | mandatory | The value of this object provides the Minor High alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.18 | ColumndrrminorLowRFBAttenuation | read-only | mandatory | The value of this object provides the Minor Low alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module an… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.19 | ColumndrrcurrentValueRFBAttenuation | read-write | mandatory | The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.20 | ColumndrrstateFlagRFBAttenuation | read-only | mandatory | The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.21 | ColumndrrminValueRFBAttenuation | read-only | mandatory | The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.22 | ColumndrrmaxValueRFBAttenuation | read-only | mandatory | The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.23 | ColumndrralarmStateRFBAttenuation | read-only | mandatory | The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.24 | ColumndrrlabelRFCAttenuation | read-only | optional | The value of this object provides the label of the RF Channel C Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.25 | ColumndrruomRFCAttenuation | read-only | optional | The value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.26 | ColumndrrmajorHighRFCAttenuation | read-only | mandatory | The value of this object provides the Major High alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.27 | ColumndrrmajorLowRFCAttenuation | read-only | mandatory | The value of this object provides the Major Low alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module an… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.28 | ColumndrrminorHighRFCAttenuation | read-only | mandatory | The value of this object provides the Minor High alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.29 | ColumndrrminorLowRFCAttenuation | read-only | mandatory | The value of this object provides the Minor Low alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module an… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.30 | ColumndrrcurrentValueRFCAttenuation | read-write | mandatory | The value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.31 | ColumndrrstateFlagRFCAttenuation | read-only | mandatory | The value of this object provides the state of the RF Channel C Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.32 | ColumndrrminValueRFCAttenuation | read-only | mandatory | The value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.33 | ColumndrrmaxValueRFCAttenuation | read-only | mandatory | The value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.34 | ColumndrralarmStateRFCAttenuation | read-only | mandatory | The value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.35 | ColumndrrlabelTrippointLevel | read-only | optional | The value of this object provides the label of the trip point level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.36 | ColumndrruomTrippointLevel | read-only | optional | The value of this object provides the Unit of Measure of the trip point level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.37 | ColumndrrmajorHighTrippointLevel | read-only | mandatory | The value of this object provides the Major High alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.38 | ColumndrrmajorLowTrippointLevel | read-only | mandatory | The value of this object provides the Major Low alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set as… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.39 | ColumndrrminorHighTrippointLevel | read-only | mandatory | The value of this object provides the Minor High alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.40 | ColumndrrminorLowTrippointLevel | read-only | mandatory | The value of this object provides the Minor Low alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set as… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.41 | ColumndrrcurrentValueTrippointLevel | read-write | mandatory | The value of this object provides the Current value of the trippoint level Analog parameter. The trip point level set the custumer preferred optical input leve… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.42 | ColumndrrstateFlagTrippointLevel | read-only | mandatory | The value of this object provides the state of the trip point level Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.43 | ColumndrrminValueTrippointLevel | read-only | mandatory | The value of this object provides the minimum value the trip point level Analog parameter can achive. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.44 | ColumndrrmaxValueTrippointLevel | read-only | mandatory | The value of this object provides the maximum value the trip point level Analog parameter can achive. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.45 | ColumndrralarmStateTrippointLevel | read-only | mandatory | The value of this object provides the curent alarm state of the trip point level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.46 | ColumndrrlabelOptCurrent | read-only | optional | The value of this object provides the label of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.47 | ColumndrruomOptCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.48 | ColumndrrmajorHighOptCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is repre… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.49 | ColumndrrmajorLowOptCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.50 | ColumndrrminorHighOptCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Current Analog parameter. This parameter has not been used by the module and … |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.51 | ColumndrrminorLowOptCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Current Analog parameter. This parameter has not been used by the module and s… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.52 | ColumndrrcurrentValueOptCurrent | read-only | mandatory | The value of this object provides the Current value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.53 | ColumndrrstateFlagOptCurrent | read-only | mandatory | The value of this object provides the state of the Optical Power Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.54 | ColumndrrminValueOptCurrent | read-only | mandatory | The value of this object provides the minimum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.55 | ColumndrrmaxValueOptCurrent | read-only | mandatory | The value of this object provides the maximum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.56 | ColumndrralarmStateOptCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.57 | Columndrrlabel12VCurrent | read-only | optional | The value of this object provides the label of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.58 | Columndrruom12VCurrent | read-only | optional | The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.59 | ColumndrrmajorHigh12VCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.60 | ColumndrrmajorLow12VCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.61 | ColumndrrminorHigh12VCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.62 | ColumndrrminorLow12VCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.63 | ColumndrrcurrentValue12VCurrent | read-only | mandatory | The value of this object provides the Current value of the 12v power supply Current parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.64 | ColumndrrstateFlag12VCurrent | read-only | mandatory | The value of this object provides the state of the 12v power supply Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.65 | ColumndrrminValue12VCurrent | read-only | mandatory | The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.66 | ColumndrrmaxValue12VCurrent | read-only | mandatory | The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.67 | ColumndrralarmState12VCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.68 | ColumndrrlabelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.69 | ColumndrruomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.70 | ColumndrrmajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.71 | ColumndrrmajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.72 | ColumndrrminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.73 | ColumndrrminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.74 | ColumndrrcurrentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.75 | ColumndrrstateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.76 | ColumndrrminValueModTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.77 | ColumndrrmaxValueModTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.78 | ColumndrralarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.79 | ColumndrrlabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.80 | ColumndrruomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.81 | ColumndrrmajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.82 | ColumndrrmajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.83 | ColumndrrminorHighFanCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This parameter has not been used by the module and set as the… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.84 | ColumndrrminorLowFanCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This parameter has not been used by the module and set as the … |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.85 | ColumndrrcurrentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.86 | ColumndrrstateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.87 | ColumndrrminValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.88 | ColumndrrmaxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.13.2.1.89 | ColumndrralarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.3 | Tablegx2drr3xDigitalTable | not-accessible | mandatory | This table contains gx2drr3x specific digital parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.13.3 | Nodetrapdrr12VCurrentAlarm | This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this para… | ||
| 1.3.6.1.4.1.1166.6.1.2.13.3.2 | Rowgx2drr3xDigitalEntry | not-accessible | mandatory | This list contains digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.1 | Columngx2drr3xDigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.2 | ColumndrrlabelTrippointMode | read-only | optional | The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical pow… |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.3 | ColumndrrenumTrippointMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.4 | ColumndrrvalueTrippointMode | read-write | mandatory | The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical … |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.5 | ColumndrrstateflagTrippointMode | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.6 | ColumndrrlabelFrontPanelTest | read-only | optional | The value of this object provides the label of the Front panel test point Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.7 | ColumndrrenumFrontPanelTest | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.8 | ColumndrrvalueFrontPanelTest | read-write | mandatory | The value of this object is the current value of Front panel RF test point Channel number |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.9 | ColumndrrstateflagFrontPanelTest | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.10 | ColumndrrlabelFactoryDefaultReset | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.11 | ColumndrrenumFactoryDefaultReset | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.12 | ColumndrrvalueFactoryDefaultReset | read-write | mandatory | The read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter |
| 1.3.6.1.4.1.1166.6.1.2.13.3.2.13 | ColumndrrstateflagFactoryDefaultReset | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.4 | Tablegx2drr3xStatusTable | not-accessible | mandatory | This table contains gx2drr3x specific status parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.13.4 | NodetrapdrrModuleTempAlarm | This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.13.4.3 | Rowgx2drr3xStatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.1 | Columngx2drr3xStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.2 | ColumndrrlabelBoot | read-only | optional | The value of this object provides the label of the Boot Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.3 | ColumndrrvalueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.4 | ColumndrrstateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.5 | ColumndrrlabelFlash | read-only | optional | The value of this object provides the label of the Flash Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.6 | ColumndrrvalueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.7 | ColumndrrstateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.8 | ColumndrrlabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.9 | ColumndrrvalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.10 | ColumndrrstateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.11 | ColumndrrlabelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.12 | ColumndrrvalueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.13 | ColumndrrstateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.14 | ColumndrrlabelHardwareStatus | read-only | optional | The value of this object provides the label of the Module Hardware Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.15 | ColumndrrvalueHardwareStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.16 | ColumndrrstateflagHardwareStatus | read-only | mandatory | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.17 | ColumndrrlabelOpticTripPointStatus | read-only | optional | The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip poin… |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.18 | ColumndrrvalueOpticTripPointStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.19 | ColumndrrstateflagOpticTripPointStatus | read-only | mandatory | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.20 | ColumndrrlabelLinkStatus | read-only | optional | The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect t… |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.21 | ColumndrrvalueLinkStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.13.4.3.22 | ColumndrrstateflagLinkStatus | read-only | mandatory | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.13.5 | Tablegx2drr3xFactoryTable | not-accessible | mandatory | This table contains gx2drr3x specific factory setting parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.13.5 | NodetrapdrrFanCurrentAlarm | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.13.5.4 | Rowgx2drr3xFactoryEntry | not-accessible | mandatory | This list contains Factory setting parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.1 | Columngx2drr3xFactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.2 | ColumndrrbootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.3 | ColumndrrbootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.4 | Columndrrbank1CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.5 | Columndrrbank2CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.6 | ColumndrrprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.7 | ColumndrrfactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.8 | ColumndrrcalculateCRC | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.9 | ColumndrrhourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.10 | ColumndrrflashPrgCntA | read-only | mandatory | This object provides the number of times Bank 0 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.11 | ColumndrrflashPrgCntB | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.12 | ColumndrrflashBankARev | read-only | mandatory | This object provides the revision of flash bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.13.5.4.13 | ColumndrrflashBankBRev | read-only | mandatory | This object provides the revision of flash bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.13.6 | NodetrapdrrFlashAlarm | This trap is issued when the detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.13.7 | NodetrapdrrBankBootAlarm | This trap is issued when the detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.13.8 | NodetrapdrrAlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.13.9 | NodetrapdrrHardwareErrAlarm | This trap is issued when hardware is abnormal. | ||
| 1.3.6.1.4.1.1166.6.1.2.13.10 | NodetrapdrrOpticalSignalAlarm | This trap is issued when the optical signal is beyond the reason range. | ||
| 1.3.6.1.4.1.1166.6.1.2.13.11 | NodetrapdrrFactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.13.12 | NodetrapdrrResetFactoryDefaultAlarm | This trap is issued when the Factory Default Reset occurs. | ||
| 1.3.6.1.4.1.1166.6.1.2.13.13 | NodetrapdrrTripPointAlarm | This trap is issued when the Input optical power is lower than the custumer set trip point. | ||
| 1.3.6.1.4.1.1166.6.1.2.13.14 | NodetrapdrrLinkAlarm | This trap is issued when receiver is out of SYN with transmitter |