MIB Viewer

OMNI-gx2drt4x-MIB

202 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.25.1Nodegx2drt4xDescriptor
1.3.6.1.4.1.1166.6.1.2.25.1Nodetrapdrt4xConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.25.2Tablegx2drt4xAnalogTablenot-accessiblemandatoryThis table contains Gx2drt4x specific analog parameters with nominal,limits and current values.
1.3.6.1.4.1.1166.6.1.2.25.2Nodetrapdrt4xConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.25.2.1Rowgx2drt4xAnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.25.2.1.1Columngx2drt4xAnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.25.2.1.2Columndrt4xlabelRFAAttenuationread-onlyoptionalThe value of this object provides the label of the RF Channel A Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.3Columndrt4xuomRFAAttenuationread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.4Columndrt4xmajorHighRFAAttenuationread-onlymandatoryThe value of this object provides the Major High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module a…
1.3.6.1.4.1.1166.6.1.2.25.2.1.5Columndrt4xmajorLowRFAAttenuationread-onlymandatoryThe value of this object provides the Major Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module an…
1.3.6.1.4.1.1166.6.1.2.25.2.1.6Columndrt4xminorHighRFAAttenuationread-onlymandatoryThe value of this object provides the Minor High alarm value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is re…
1.3.6.1.4.1.1166.6.1.2.25.2.1.7Columndrt4xminorLowRFAAttenuationread-onlymandatoryThe value of this object provides the Minor Low alarm value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.8Columndrt4xvalueRFAAttenuationread-writemandatoryThe value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.25.2.1.9Columndrt4xstateFlagRFAAttenuationread-onlymandatoryThe value of this object provides the state of the RF Channel A Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.10Columndrt4xminValueRFAAttenuationread-onlymandatoryThe value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.11Columndrt4xmaxValueRFAAttenuationread-onlymandatoryThe value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive.which is 31.0 This value is a floating point numbe…
1.3.6.1.4.1.1166.6.1.2.25.2.1.12Columndrt4xalarmStateRFAAttenuationread-onlymandatoryThe value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.13Columndrt4xlabelRFBAttenuationread-onlyoptionalThe value of this object provides the label of the RF Channel B Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.14Columndrt4xuomRFBAttenuationread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.15Columndrt4xmajorHighRFBAttenuationread-onlymandatoryThe value of this object provides the Major High alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is re…
1.3.6.1.4.1.1166.6.1.2.25.2.1.16Columndrt4xmajorLowRFBAttenuationread-onlymandatoryThe value of this object provides the Major Low alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.17Columndrt4xminorHighRFBAttenuationread-onlymandatoryThe value of this object provides the Minor High alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is re…
1.3.6.1.4.1.1166.6.1.2.25.2.1.18Columndrt4xminorLowRFBAttenuationread-onlymandatoryThe value of this object provides the Minor Low alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.19Columndrt4xvalueRFBAttenuationread-writemandatoryThe value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.25.2.1.20Columndrt4xstateFlagRFBAttenuationread-onlymandatoryThe value of this object provides the state of the RF Channel B Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.21Columndrt4xminValueRFBAttenuationread-onlymandatoryThe value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.22Columndrt4xmaxValueRFBAttenuationread-onlymandatoryThe value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive.which is 31.0 This value is a floating point numbe…
1.3.6.1.4.1.1166.6.1.2.25.2.1.23Columndrt4xalarmStateRFBAttenuationread-onlymandatoryThe value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.24Columndrt4xlabelRFCAttenuationread-onlyoptionalThe value of this object provides the label of the RF Channel C Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.25Columndrt4xuomRFCAttenuationread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.26Columndrt4xmajorHighRFCAttenuationread-onlymandatoryThe value of this object provides the Major High alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is re…
1.3.6.1.4.1.1166.6.1.2.25.2.1.27Columndrt4xmajorLowRFCAttenuationread-onlymandatoryThe value of this object provides the Major Low alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.28Columndrt4xminorHighRFCAttenuationread-onlymandatoryThe value of this object provides the Minor High alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is re…
1.3.6.1.4.1.1166.6.1.2.25.2.1.29Columndrt4xminorLowRFCAttenuationread-onlymandatoryThe value of this object provides the Minor Low alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.30Columndrt4xvalueRFCAttenuationread-writemandatoryThe value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.25.2.1.31Columndrt4xstateFlagRFCAttenuationread-onlymandatoryThe value of this object provides the state of the RF Channel C Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.32Columndrt4xminValueRFCAttenuationread-onlymandatoryThe value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.33Columndrt4xmaxValueRFCAttenuationread-onlymandatoryThe value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive.which is 31.0 This value is a floating point numbe…
1.3.6.1.4.1.1166.6.1.2.25.2.1.34Columndrt4xalarmStateRFCAttenuationread-onlymandatoryThe value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.35Columndrt4xlabelRFDAttenuationread-onlyoptionalThe value of this object provides the label of the RF Channel D Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.36Columndrt4xuomRFDAttenuationread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Channel D Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.37Columndrt4xmajorHighRFDAttenuationread-onlymandatoryThe value of this object provides the Major High alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is re…
1.3.6.1.4.1.1166.6.1.2.25.2.1.38Columndrt4xmajorLowRFDAttenuationread-onlymandatoryThe value of this object provides the Major Low alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.39Columndrt4xminorHighRFDAttenuationread-onlymandatoryThe value of this object provides the Minor High alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is re…
1.3.6.1.4.1.1166.6.1.2.25.2.1.40Columndrt4xminorLowRFDAttenuationread-onlymandatoryThe value of this object provides the Minor Low alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.41Columndrt4xvalueRFDAttenuationread-writemandatoryThe value of this object provides the Current value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.25.2.1.42Columndrt4xstateFlagRFDAttenuationread-onlymandatoryThe value of this object provides the state of the RF Channel D Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.43Columndrt4xminValueRFDAttenuationread-onlymandatoryThe value of this object provides the minimum value the RF Channel D Attenuation Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.44Columndrt4xmaxValueRFDAttenuationread-onlymandatoryThe value of this object provides the maximum value the RF Channel D Attenuation Analog parameter can achive.which is 31.0 This value is a floating point numbe…
1.3.6.1.4.1.1166.6.1.2.25.2.1.45Columndrt4xalarmStateRFDAttenuationread-onlymandatoryThe value of this object provides the curent alarm state of the RF Channel D Attenuation Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.46Columndrt4xlabelLaserPowerMonitorread-onlyoptionalThe value of this object provides the label of the trip point level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.47Columndrt4xuomLaserPowerMonitorread-onlyoptionalThe value of this object provides the Unit of Measure of the trip point level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.48Columndrt4xmajorHighLaserPowerMonitorread-onlymandatoryThe value of this object provides the Major High alarm value of the trip point level Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.25.2.1.49Columndrt4xmajorLowLaserPowerMonitorread-onlymandatoryThe value of this object provides the Major Low alarm value of the trip point level Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.25.2.1.50Columndrt4xminorHighLaserPowerMonitorread-onlymandatoryThe value of this object provides the Minor High alarm value of the trip point level Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.25.2.1.51Columndrt4xminorLowLaserPowerMonitorread-onlymandatoryThe value of this object provides the Minor Low alarm value of the trip point level Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.25.2.1.52Columndrt4xvalueLaserPowerMonitorread-onlymandatoryThe value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input lev…
1.3.6.1.4.1.1166.6.1.2.25.2.1.53Columndrt4xstateFlagLaserPowerMonitorread-onlymandatoryThe value of this object provides the state of the trip point level Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.54Columndrt4xminValueLaserPowerMonitorread-onlymandatoryThe value of this object provides the minimum value the trip point level Analog parameter can achive. The minimum value is -19dBm This value is a floating poin…
1.3.6.1.4.1.1166.6.1.2.25.2.1.55Columndrt4xmaxValueLaserPowerMonitorread-onlymandatoryThe value of this object provides the maximum value the trip point level Analog parameter can achive.which is -1dBm This value is a floating point number that …
1.3.6.1.4.1.1166.6.1.2.25.2.1.56Columndrt4xalarmStateLaserPowerMonitorread-onlymandatoryThe value of this object provides the curent alarm state of the trip point level Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.57Columndrt4xlabelLaserBiasCurrentread-onlyoptionalThe value of this object provides the label of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.58Columndrt4xuomLaserBiasCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.59Columndrt4xmajorHighLaserBiasCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is repre…
1.3.6.1.4.1.1166.6.1.2.25.2.1.60Columndrt4xmajorLowLaserBiasCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.25.2.1.61Columndrt4xminorHighLaserBiasCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is repre…
1.3.6.1.4.1.1166.6.1.2.25.2.1.62Columndrt4xminorLowLaserBiasCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.25.2.1.63Columndrt4xvalueLaserBiasCurrentread-onlymandatoryThe value of this object provides the Current value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.25.2.1.64Columndrt4xstateFlagLaserBiasCurrentread-onlymandatoryThe value of this object provides the state of the Optical Power Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.65Columndrt4xminValueLaserBiasCurrentread-onlymandatoryThe value of this object provides the minimum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.25.2.1.66Columndrt4xmaxValueLaserBiasCurrentread-onlymandatoryThe value of this object provides the maximum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.25.2.1.67Columndrt4xalarmStateLaserBiasCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.68Columndrt4xlabelLaserTECTemperatureread-onlyoptionalThe value of this object provides the label of the Laser TEC Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.69Columndrt4xuomLaserTECTemperatureread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser TEC Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.70Columndrt4xmajorHighLaserTECTemperatureread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is repre…
1.3.6.1.4.1.1166.6.1.2.25.2.1.71Columndrt4xmajorLowLaserTECTemperatureread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.25.2.1.72Columndrt4xminorHighLaserTECTemperatureread-onlymandatoryThe value of this object provides the Minor High alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is repre…
1.3.6.1.4.1.1166.6.1.2.25.2.1.73Columndrt4xminorLowLaserTECTemperatureread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.25.2.1.74Columndrt4xvalueLaserTECTemperatureread-onlymandatoryThe value of this object provides the Current value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.25.2.1.75Columndrt4xstateFlagLaserTECTemperatureread-onlymandatoryThe value of this object provides the state of the Laser TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.76Columndrt4xminValueLaserTECTemperatureread-onlymandatoryThe value of this object provides the minimum value the Laser TEC Temperature Analog parameter can achive. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.25.2.1.77Columndrt4xmaxValueLaserTECTemperatureread-onlymandatoryThe value of this object provides the maximum value the Laser TEC Temperature Analog parameter can achive. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.25.2.1.78Columndrt4xalarmStateLaserTECTemperatureread-onlymandatoryThe value of this object provides the curent alarm state of the Laser TEC Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.79Columndrt4xlabelLaserTECCurrentread-onlyoptionalThe value of this object provides the label of the Laser TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.80Columndrt4xuomLaserTECCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.81Columndrt4xmajorHighLaserTECCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.25.2.1.82Columndrt4xmajorLowLaserTECCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.25.2.1.83Columndrt4xminorHighLaserTECCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.25.2.1.84Columndrt4xminorLowLaserTECCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.25.2.1.85Columndrt4xvalueLaserTECCurrentread-onlymandatoryThe value of this object provides the Current value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an …
1.3.6.1.4.1.1166.6.1.2.25.2.1.86Columndrt4xstateFlagLaserTECCurrentread-onlymandatoryThe value of this object provides the state of the Laser TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.87Columndrt4xminValueLaserTECCurrentread-onlymandatoryThe value of this object provides the minimum value the Laser TEC Current Analog parameter can achive. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.25.2.1.88Columndrt4xmaxValueLaserTECCurrentread-onlymandatoryThe value of this object provides the maximum value the Laser TEC Current Analog parameter can achive. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.25.2.1.89Columndrt4xalarmStateLaserTECCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Laser TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.90Columndrt4xlabel12VCurrentread-onlyoptionalThe value of this object provides the label of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.91Columndrt4xuom12VCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.92Columndrt4xmajorHigh12VCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is re…
1.3.6.1.4.1.1166.6.1.2.25.2.1.93Columndrt4xmajorLow12VCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.94Columndrt4xminorHigh12VCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is re…
1.3.6.1.4.1.1166.6.1.2.25.2.1.95Columndrt4xminorLow12VCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.96Columndrt4xvalue12VCurrentread-onlymandatoryThe value of this object provides the Current value of the 12v power supply Current parameter. This value is a floating point number that is represented as an …
1.3.6.1.4.1.1166.6.1.2.25.2.1.97Columndrt4xstateFlag12VCurrentread-onlymandatoryThe value of this object provides the state of the 12v power supply Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.98Columndrt4xminValue12VCurrentread-onlymandatoryThe value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.99Columndrt4xmaxValue12VCurrentread-onlymandatoryThe value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.25.2.1.100Columndrt4xalarmState12VCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the 12v power supply Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.101Columndrt4xlabelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.102Columndrt4xuomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.103Columndrt4xmajorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.25.2.1.104Columndrt4xmajorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.25.2.1.105Columndrt4xminorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.25.2.1.106Columndrt4xminorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.25.2.1.107Columndrt4xvalueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.25.2.1.108Columndrt4xstateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.109Columndrt4xminValueModTempread-onlymandatoryThe value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.25.2.1.110Columndrt4xmaxValueModTempread-onlymandatoryThe value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.25.2.1.111Columndrt4xalarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.112Columndrt4xlabelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.113Columndrt4xuomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.2.1.114Columndrt4xmajorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.25.2.1.115Columndrt4xmajorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.25.2.1.116Columndrt4xminorHighFanCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.25.2.1.117Columndrt4xminorLowFanCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.25.2.1.118Columndrt4xvalueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32…
1.3.6.1.4.1.1166.6.1.2.25.2.1.119Columndrt4xstateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.2.1.120Columndrt4xminValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.25.2.1.121Columndrt4xmaxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.25.2.1.122Columndrt4xalarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.25.3Tablegx2drt4xDigitalTablenot-accessiblemandatoryThis table contains gx2drt4x specific digital parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.25.3Nodetrapdrt4xModulePlus12CurrentAlarmThis trap is issued when the Module +12V Supply Current goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.25.3.2Rowgx2drt4xDigitalEntrynot-accessiblemandatoryThis list contains digital parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.25.3.2.1Columngx2drt4xDigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.25.3.2.2Columndrt4xlabelBaseITUChannelread-onlyoptionalThe value of this object provides the label of the Base ITU Channel Digital parameter.
1.3.6.1.4.1.1166.6.1.2.25.3.2.3Columndrt4xenumBaseITUChannelread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma.
1.3.6.1.4.1.1166.6.1.2.25.3.2.4Columndrt4xvalueBaseITUChannelread-onlymandatoryThe value of this object is the value of the Base ITU Channel. There are 10 possible value: 1-ch20, 2-ch24, 3-ch28, 4-ch32, 5-ch36, 6-ch40, 7-ch44, 8-ch48, 9-c…
1.3.6.1.4.1.1166.6.1.2.25.3.2.5Columndrt4xstateflagBaseITUChannelread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.3.2.6Columndrt4xlabelITUChannelSettingread-writeoptionalThe value of this object provides the label of the ITU Channel Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.25.3.2.7Columndrt4xenumITUChannelSettingread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma.
1.3.6.1.4.1.1166.6.1.2.25.3.2.8Columndrt4xvalueITUChannelSettingread-writemandatoryThe value of this object is the value of the ITU Channel Setting. There are 4 possible value: 1-base (base ITU channel), 2-basePlus1 (base ITU Channel + 1), 3-…
1.3.6.1.4.1.1166.6.1.2.25.3.2.9Columndrt4xstateflagITUChannelSettingread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.3.2.10Columndrt4xlabelOpticalPowerSettingread-onlyoptionalThe value of this object provides the label of the Optical Power Setting Digital parameter. This parameter defines the operating power level of the DRT-4X
1.3.6.1.4.1.1166.6.1.2.25.3.2.11Columndrt4xenumOpticalPowerSettingread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
1.3.6.1.4.1.1166.6.1.2.25.3.2.12Columndrt4xvalueOpticalPowerSettingread-writemandatoryThe value of this object is the setting of the Optical Power. There are two possible value: 1-low, and 2-high.
1.3.6.1.4.1.1166.6.1.2.25.3.2.13Columndrt4xstateflagOpticalPowerSettingread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.3.2.14Columndrt4xlabelLaserControlread-onlyoptionalThe value of this object provides the label of the Laser Control Digital parameter. The Laser Control allows the DRT-4X laser to be turned off or on.
1.3.6.1.4.1.1166.6.1.2.25.3.2.15Columndrt4xenumLaserControlread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma.
1.3.6.1.4.1.1166.6.1.2.25.3.2.16Columndrt4xvalueLaserControlread-writemandatoryThe value of this object represents the Laser Control. There are two possible values: 1-off, and 2-on.
1.3.6.1.4.1.1166.6.1.2.25.3.2.17Columndrt4xstateflagLaserControlread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.3.2.18Columndrt4xlabelFactoryDefaultResetread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.25.3.2.19Columndrt4xenumFactoryDefaultResetread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.25.3.2.20Columndrt4xvalueFactoryDefaultResetread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.25.3.2.21Columndrt4xstateflagFactoryDefaultResetread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.4Tablegx2drt4xStatusTablenot-accessiblemandatoryThis table contains gx2drt4x specific status parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.25.4Nodetrapdrt4xModuleTempAlarmThis trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.25.4.3Rowgx2drt4xStatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.25.4.3.1Columngx2drt4xStatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.25.4.3.2Columndrt4xlabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status parameter.
1.3.6.1.4.1.1166.6.1.2.25.4.3.3Columndrt4xvalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.25.4.3.4Columndrt4xstateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.4.3.5Columndrt4xlabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status parameter.
1.3.6.1.4.1.1166.6.1.2.25.4.3.6Columndrt4xvalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.25.4.3.7Columndrt4xstateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.4.3.8Columndrt4xlabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.25.4.3.9Columndrt4xvalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.25.4.3.10Columndrt4xstateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.4.3.11Columndrt4xlabelAlarmDataCrcread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.25.4.3.12Columndrt4xvalueAlarmDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.25.4.3.13Columndrt4xstateflagAlarmDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.4.3.14Columndrt4xlabelCalibrationDataCrcread-onlyoptionalThe value of this object provides the label of the Calibration Data CRC parameter.
1.3.6.1.4.1.1166.6.1.2.25.4.3.15Columndrt4xvalueCalibrationDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.25.4.3.16Columndrt4xstateflagCalibrationDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.4.3.17Columndrt4xlabelHardwareStatusread-onlyoptionalThe value of this object provides the label of the Module Hardware Status parameter.
1.3.6.1.4.1.1166.6.1.2.25.4.3.18Columndrt4xvalueHardwareStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.25.4.3.19Columndrt4xstateflagHardwareStatusread-onlymandatoryThe value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.25.5Tablegx2drt4xFactoryTablenot-accessiblemandatoryThis table contains gx2drt4x specific factory setting parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.25.5Nodetrapdrt4xFanCurrentAlarmThis trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.25.5.4Rowgx2drt4xFactoryEntrynot-accessiblemandatoryThis list contains Factory setting parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.25.5.4.1Columngx2drt4xFactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.25.5.4.2Columndrt4xbootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.25.5.4.3Columndrt4xbootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.25.5.4.4Columndrt4xbank1CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.25.5.4.5Columndrt4xbank2CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.25.5.4.6Columndrt4xprgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.25.5.4.7Columndrt4xfactoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.25.5.4.8Columndrt4xcalculateCRCread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.25.5.4.9Columndrt4xhourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.25.5.4.10Columndrt4xflashPrgCntAread-onlymandatoryThis object provides the number of times Bank 0 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.25.5.4.11Columndrt4xflashPrgCntBread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.25.5.4.12Columndrt4xflashBankARevread-onlymandatoryThis object provides the revision of flash bank 0.
1.3.6.1.4.1.1166.6.1.2.25.5.4.13Columndrt4xflashBankBRevread-onlymandatoryThis object provides the revision of flash bank 1.
1.3.6.1.4.1.1166.6.1.2.25.5.4.14Columndrt4xSubAgentRevread-onlymandatoryThis object provides the subagent revision of receiver module.
1.3.6.1.4.1.1166.6.1.2.25.6Nodetrapdrt4xFlashAlarmThis trap is issued when the detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.25.7Nodetrapdrt4xBankBootAlarmThis trap is issued when the detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.25.8Nodetrapdrt4xFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.25.9Nodetrapdrt4xAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.25.10Nodetrapdrt4xCalibrationDataCRCAlarmThis trap is issued when the Calibration Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.25.11Nodetrapdrt4xHardwareErrorAlarmThis trap is issued when hardware is abnormal.
1.3.6.1.4.1.1166.6.1.2.25.12Nodetrapdrt4xOpticalPowerAlarmThis trap is issued when the optical power is out of range.
1.3.6.1.4.1.1166.6.1.2.25.13Nodetrapdrt4xTECTemperatureAlarmThis trap is issued when the TEC Temperature is out of range.
1.3.6.1.4.1.1166.6.1.2.25.14Nodetrapdrt4xTECCurrentAlarmThis trap is issued when the TEC Current is out of range.
1.3.6.1.4.1.1166.6.1.2.25.15Nodetrapdrt4xLaserBiasCurrentAlarmThis trap is issued when the Laser Bias Current is out of range.
1.3.6.1.4.1.1166.6.1.2.25.16Nodetrapdrt4xResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs.
1.3.6.1.4.1.1166.6.1.2.25.17Nodetrapdrt4xLaserOnOffInfoThis trap is issued when the When the Laser turns on/off.