OMNI-gx2drt4x-MIB
202 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.25.1 | Nodegx2drt4xDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.25.1 | Nodetrapdrt4xConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.25.2 | Tablegx2drt4xAnalogTable | not-accessible | mandatory | This table contains Gx2drt4x specific analog parameters with nominal,limits and current values. |
| 1.3.6.1.4.1.1166.6.1.2.25.2 | Nodetrapdrt4xConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.25.2.1 | Rowgx2drt4xAnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.1 | Columngx2drt4xAnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.2 | Columndrt4xlabelRFAAttenuation | read-only | optional | The value of this object provides the label of the RF Channel A Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.3 | Columndrt4xuomRFAAttenuation | read-only | optional | The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.4 | Columndrt4xmajorHighRFAAttenuation | read-only | mandatory | The value of this object provides the Major High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module a… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.5 | Columndrt4xmajorLowRFAAttenuation | read-only | mandatory | The value of this object provides the Major Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module an… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.6 | Columndrt4xminorHighRFAAttenuation | read-only | mandatory | The value of this object provides the Minor High alarm value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.7 | Columndrt4xminorLowRFAAttenuation | read-only | mandatory | The value of this object provides the Minor Low alarm value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.8 | Columndrt4xvalueRFAAttenuation | read-write | mandatory | The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.9 | Columndrt4xstateFlagRFAAttenuation | read-only | mandatory | The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.10 | Columndrt4xminValueRFAAttenuation | read-only | mandatory | The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.11 | Columndrt4xmaxValueRFAAttenuation | read-only | mandatory | The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive.which is 31.0 This value is a floating point numbe… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.12 | Columndrt4xalarmStateRFAAttenuation | read-only | mandatory | The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.13 | Columndrt4xlabelRFBAttenuation | read-only | optional | The value of this object provides the label of the RF Channel B Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.14 | Columndrt4xuomRFBAttenuation | read-only | optional | The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.15 | Columndrt4xmajorHighRFBAttenuation | read-only | mandatory | The value of this object provides the Major High alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.16 | Columndrt4xmajorLowRFBAttenuation | read-only | mandatory | The value of this object provides the Major Low alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.17 | Columndrt4xminorHighRFBAttenuation | read-only | mandatory | The value of this object provides the Minor High alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.18 | Columndrt4xminorLowRFBAttenuation | read-only | mandatory | The value of this object provides the Minor Low alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.19 | Columndrt4xvalueRFBAttenuation | read-write | mandatory | The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.20 | Columndrt4xstateFlagRFBAttenuation | read-only | mandatory | The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.21 | Columndrt4xminValueRFBAttenuation | read-only | mandatory | The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.22 | Columndrt4xmaxValueRFBAttenuation | read-only | mandatory | The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive.which is 31.0 This value is a floating point numbe… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.23 | Columndrt4xalarmStateRFBAttenuation | read-only | mandatory | The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.24 | Columndrt4xlabelRFCAttenuation | read-only | optional | The value of this object provides the label of the RF Channel C Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.25 | Columndrt4xuomRFCAttenuation | read-only | optional | The value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.26 | Columndrt4xmajorHighRFCAttenuation | read-only | mandatory | The value of this object provides the Major High alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.27 | Columndrt4xmajorLowRFCAttenuation | read-only | mandatory | The value of this object provides the Major Low alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.28 | Columndrt4xminorHighRFCAttenuation | read-only | mandatory | The value of this object provides the Minor High alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.29 | Columndrt4xminorLowRFCAttenuation | read-only | mandatory | The value of this object provides the Minor Low alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.30 | Columndrt4xvalueRFCAttenuation | read-write | mandatory | The value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.31 | Columndrt4xstateFlagRFCAttenuation | read-only | mandatory | The value of this object provides the state of the RF Channel C Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.32 | Columndrt4xminValueRFCAttenuation | read-only | mandatory | The value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.33 | Columndrt4xmaxValueRFCAttenuation | read-only | mandatory | The value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive.which is 31.0 This value is a floating point numbe… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.34 | Columndrt4xalarmStateRFCAttenuation | read-only | mandatory | The value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.35 | Columndrt4xlabelRFDAttenuation | read-only | optional | The value of this object provides the label of the RF Channel D Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.36 | Columndrt4xuomRFDAttenuation | read-only | optional | The value of this object provides the Unit of Measure of the RF Channel D Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.37 | Columndrt4xmajorHighRFDAttenuation | read-only | mandatory | The value of this object provides the Major High alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.38 | Columndrt4xmajorLowRFDAttenuation | read-only | mandatory | The value of this object provides the Major Low alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.39 | Columndrt4xminorHighRFDAttenuation | read-only | mandatory | The value of this object provides the Minor High alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.40 | Columndrt4xminorLowRFDAttenuation | read-only | mandatory | The value of this object provides the Minor Low alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.41 | Columndrt4xvalueRFDAttenuation | read-write | mandatory | The value of this object provides the Current value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.42 | Columndrt4xstateFlagRFDAttenuation | read-only | mandatory | The value of this object provides the state of the RF Channel D Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.43 | Columndrt4xminValueRFDAttenuation | read-only | mandatory | The value of this object provides the minimum value the RF Channel D Attenuation Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.44 | Columndrt4xmaxValueRFDAttenuation | read-only | mandatory | The value of this object provides the maximum value the RF Channel D Attenuation Analog parameter can achive.which is 31.0 This value is a floating point numbe… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.45 | Columndrt4xalarmStateRFDAttenuation | read-only | mandatory | The value of this object provides the curent alarm state of the RF Channel D Attenuation Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.46 | Columndrt4xlabelLaserPowerMonitor | read-only | optional | The value of this object provides the label of the trip point level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.47 | Columndrt4xuomLaserPowerMonitor | read-only | optional | The value of this object provides the Unit of Measure of the trip point level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.48 | Columndrt4xmajorHighLaserPowerMonitor | read-only | mandatory | The value of this object provides the Major High alarm value of the trip point level Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.49 | Columndrt4xmajorLowLaserPowerMonitor | read-only | mandatory | The value of this object provides the Major Low alarm value of the trip point level Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.50 | Columndrt4xminorHighLaserPowerMonitor | read-only | mandatory | The value of this object provides the Minor High alarm value of the trip point level Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.51 | Columndrt4xminorLowLaserPowerMonitor | read-only | mandatory | The value of this object provides the Minor Low alarm value of the trip point level Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.52 | Columndrt4xvalueLaserPowerMonitor | read-only | mandatory | The value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input lev… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.53 | Columndrt4xstateFlagLaserPowerMonitor | read-only | mandatory | The value of this object provides the state of the trip point level Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.54 | Columndrt4xminValueLaserPowerMonitor | read-only | mandatory | The value of this object provides the minimum value the trip point level Analog parameter can achive. The minimum value is -19dBm This value is a floating poin… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.55 | Columndrt4xmaxValueLaserPowerMonitor | read-only | mandatory | The value of this object provides the maximum value the trip point level Analog parameter can achive.which is -1dBm This value is a floating point number that … |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.56 | Columndrt4xalarmStateLaserPowerMonitor | read-only | mandatory | The value of this object provides the curent alarm state of the trip point level Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.57 | Columndrt4xlabelLaserBiasCurrent | read-only | optional | The value of this object provides the label of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.58 | Columndrt4xuomLaserBiasCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.59 | Columndrt4xmajorHighLaserBiasCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is repre… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.60 | Columndrt4xmajorLowLaserBiasCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.61 | Columndrt4xminorHighLaserBiasCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is repre… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.62 | Columndrt4xminorLowLaserBiasCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.63 | Columndrt4xvalueLaserBiasCurrent | read-only | mandatory | The value of this object provides the Current value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.64 | Columndrt4xstateFlagLaserBiasCurrent | read-only | mandatory | The value of this object provides the state of the Optical Power Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.65 | Columndrt4xminValueLaserBiasCurrent | read-only | mandatory | The value of this object provides the minimum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.66 | Columndrt4xmaxValueLaserBiasCurrent | read-only | mandatory | The value of this object provides the maximum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.67 | Columndrt4xalarmStateLaserBiasCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.68 | Columndrt4xlabelLaserTECTemperature | read-only | optional | The value of this object provides the label of the Laser TEC Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.69 | Columndrt4xuomLaserTECTemperature | read-only | optional | The value of this object provides the Unit of Measure of the Laser TEC Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.70 | Columndrt4xmajorHighLaserTECTemperature | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is repre… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.71 | Columndrt4xmajorLowLaserTECTemperature | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.72 | Columndrt4xminorHighLaserTECTemperature | read-only | mandatory | The value of this object provides the Minor High alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is repre… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.73 | Columndrt4xminorLowLaserTECTemperature | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.74 | Columndrt4xvalueLaserTECTemperature | read-only | mandatory | The value of this object provides the Current value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.75 | Columndrt4xstateFlagLaserTECTemperature | read-only | mandatory | The value of this object provides the state of the Laser TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.76 | Columndrt4xminValueLaserTECTemperature | read-only | mandatory | The value of this object provides the minimum value the Laser TEC Temperature Analog parameter can achive. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.77 | Columndrt4xmaxValueLaserTECTemperature | read-only | mandatory | The value of this object provides the maximum value the Laser TEC Temperature Analog parameter can achive. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.78 | Columndrt4xalarmStateLaserTECTemperature | read-only | mandatory | The value of this object provides the curent alarm state of the Laser TEC Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.79 | Columndrt4xlabelLaserTECCurrent | read-only | optional | The value of this object provides the label of the Laser TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.80 | Columndrt4xuomLaserTECCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Laser TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.81 | Columndrt4xmajorHighLaserTECCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.82 | Columndrt4xmajorLowLaserTECCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.83 | Columndrt4xminorHighLaserTECCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.84 | Columndrt4xminorLowLaserTECCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.85 | Columndrt4xvalueLaserTECCurrent | read-only | mandatory | The value of this object provides the Current value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.86 | Columndrt4xstateFlagLaserTECCurrent | read-only | mandatory | The value of this object provides the state of the Laser TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.87 | Columndrt4xminValueLaserTECCurrent | read-only | mandatory | The value of this object provides the minimum value the Laser TEC Current Analog parameter can achive. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.88 | Columndrt4xmaxValueLaserTECCurrent | read-only | mandatory | The value of this object provides the maximum value the Laser TEC Current Analog parameter can achive. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.89 | Columndrt4xalarmStateLaserTECCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Laser TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.90 | Columndrt4xlabel12VCurrent | read-only | optional | The value of this object provides the label of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.91 | Columndrt4xuom12VCurrent | read-only | optional | The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.92 | Columndrt4xmajorHigh12VCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.93 | Columndrt4xmajorLow12VCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.94 | Columndrt4xminorHigh12VCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.95 | Columndrt4xminorLow12VCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.96 | Columndrt4xvalue12VCurrent | read-only | mandatory | The value of this object provides the Current value of the 12v power supply Current parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.97 | Columndrt4xstateFlag12VCurrent | read-only | mandatory | The value of this object provides the state of the 12v power supply Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.98 | Columndrt4xminValue12VCurrent | read-only | mandatory | The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.99 | Columndrt4xmaxValue12VCurrent | read-only | mandatory | The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.100 | Columndrt4xalarmState12VCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.101 | Columndrt4xlabelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.102 | Columndrt4xuomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.103 | Columndrt4xmajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.104 | Columndrt4xmajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.105 | Columndrt4xminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.106 | Columndrt4xminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.107 | Columndrt4xvalueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.108 | Columndrt4xstateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.109 | Columndrt4xminValueModTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.110 | Columndrt4xmaxValueModTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.111 | Columndrt4xalarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.112 | Columndrt4xlabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.113 | Columndrt4xuomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.114 | Columndrt4xmajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.115 | Columndrt4xmajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.116 | Columndrt4xminorHighFanCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.117 | Columndrt4xminorLowFanCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.118 | Columndrt4xvalueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.119 | Columndrt4xstateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.120 | Columndrt4xminValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.121 | Columndrt4xmaxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.122 | Columndrt4xalarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.3 | Tablegx2drt4xDigitalTable | not-accessible | mandatory | This table contains gx2drt4x specific digital parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.25.3 | Nodetrapdrt4xModulePlus12CurrentAlarm | This trap is issued when the Module +12V Supply Current goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.3.2 | Rowgx2drt4xDigitalEntry | not-accessible | mandatory | This list contains digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.1 | Columngx2drt4xDigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.2 | Columndrt4xlabelBaseITUChannel | read-only | optional | The value of this object provides the label of the Base ITU Channel Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.3 | Columndrt4xenumBaseITUChannel | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.4 | Columndrt4xvalueBaseITUChannel | read-only | mandatory | The value of this object is the value of the Base ITU Channel. There are 10 possible value: 1-ch20, 2-ch24, 3-ch28, 4-ch32, 5-ch36, 6-ch40, 7-ch44, 8-ch48, 9-c… |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.5 | Columndrt4xstateflagBaseITUChannel | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.6 | Columndrt4xlabelITUChannelSetting | read-write | optional | The value of this object provides the label of the ITU Channel Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.7 | Columndrt4xenumITUChannelSetting | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.8 | Columndrt4xvalueITUChannelSetting | read-write | mandatory | The value of this object is the value of the ITU Channel Setting. There are 4 possible value: 1-base (base ITU channel), 2-basePlus1 (base ITU Channel + 1), 3-… |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.9 | Columndrt4xstateflagITUChannelSetting | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.10 | Columndrt4xlabelOpticalPowerSetting | read-only | optional | The value of this object provides the label of the Optical Power Setting Digital parameter. This parameter defines the operating power level of the DRT-4X |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.11 | Columndrt4xenumOpticalPowerSetting | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.12 | Columndrt4xvalueOpticalPowerSetting | read-write | mandatory | The value of this object is the setting of the Optical Power. There are two possible value: 1-low, and 2-high. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.13 | Columndrt4xstateflagOpticalPowerSetting | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.14 | Columndrt4xlabelLaserControl | read-only | optional | The value of this object provides the label of the Laser Control Digital parameter. The Laser Control allows the DRT-4X laser to be turned off or on. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.15 | Columndrt4xenumLaserControl | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.16 | Columndrt4xvalueLaserControl | read-write | mandatory | The value of this object represents the Laser Control. There are two possible values: 1-off, and 2-on. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.17 | Columndrt4xstateflagLaserControl | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.18 | Columndrt4xlabelFactoryDefaultReset | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.19 | Columndrt4xenumFactoryDefaultReset | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.20 | Columndrt4xvalueFactoryDefaultReset | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.3.2.21 | Columndrt4xstateflagFactoryDefaultReset | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.4 | Tablegx2drt4xStatusTable | not-accessible | mandatory | This table contains gx2drt4x specific status parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.25.4 | Nodetrapdrt4xModuleTempAlarm | This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.4.3 | Rowgx2drt4xStatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.1 | Columngx2drt4xStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.2 | Columndrt4xlabelBoot | read-only | optional | The value of this object provides the label of the Boot Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.3 | Columndrt4xvalueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.4 | Columndrt4xstateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.5 | Columndrt4xlabelFlash | read-only | optional | The value of this object provides the label of the Flash Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.6 | Columndrt4xvalueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.7 | Columndrt4xstateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.8 | Columndrt4xlabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.9 | Columndrt4xvalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.10 | Columndrt4xstateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.11 | Columndrt4xlabelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.12 | Columndrt4xvalueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.13 | Columndrt4xstateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.14 | Columndrt4xlabelCalibrationDataCrc | read-only | optional | The value of this object provides the label of the Calibration Data CRC parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.15 | Columndrt4xvalueCalibrationDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.16 | Columndrt4xstateflagCalibrationDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.17 | Columndrt4xlabelHardwareStatus | read-only | optional | The value of this object provides the label of the Module Hardware Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.18 | Columndrt4xvalueHardwareStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.25.4.3.19 | Columndrt4xstateflagHardwareStatus | read-only | mandatory | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.25.5 | Tablegx2drt4xFactoryTable | not-accessible | mandatory | This table contains gx2drt4x specific factory setting parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.25.5 | Nodetrapdrt4xFanCurrentAlarm | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.5.4 | Rowgx2drt4xFactoryEntry | not-accessible | mandatory | This list contains Factory setting parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.1 | Columngx2drt4xFactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.2 | Columndrt4xbootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.3 | Columndrt4xbootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.4 | Columndrt4xbank1CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.5 | Columndrt4xbank2CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.6 | Columndrt4xprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.7 | Columndrt4xfactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.8 | Columndrt4xcalculateCRC | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.9 | Columndrt4xhourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.10 | Columndrt4xflashPrgCntA | read-only | mandatory | This object provides the number of times Bank 0 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.11 | Columndrt4xflashPrgCntB | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.12 | Columndrt4xflashBankARev | read-only | mandatory | This object provides the revision of flash bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.13 | Columndrt4xflashBankBRev | read-only | mandatory | This object provides the revision of flash bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.25.5.4.14 | Columndrt4xSubAgentRev | read-only | mandatory | This object provides the subagent revision of receiver module. |
| 1.3.6.1.4.1.1166.6.1.2.25.6 | Nodetrapdrt4xFlashAlarm | This trap is issued when the detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.7 | Nodetrapdrt4xBankBootAlarm | This trap is issued when the detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.8 | Nodetrapdrt4xFactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.9 | Nodetrapdrt4xAlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.10 | Nodetrapdrt4xCalibrationDataCRCAlarm | This trap is issued when the Calibration Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.11 | Nodetrapdrt4xHardwareErrorAlarm | This trap is issued when hardware is abnormal. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.12 | Nodetrapdrt4xOpticalPowerAlarm | This trap is issued when the optical power is out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.13 | Nodetrapdrt4xTECTemperatureAlarm | This trap is issued when the TEC Temperature is out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.14 | Nodetrapdrt4xTECCurrentAlarm | This trap is issued when the TEC Current is out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.15 | Nodetrapdrt4xLaserBiasCurrentAlarm | This trap is issued when the Laser Bias Current is out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.16 | Nodetrapdrt4xResetFactoryDefaultAlarm | This trap is issued when the Factory Default Reset occurs. | ||
| 1.3.6.1.4.1.1166.6.1.2.25.17 | Nodetrapdrt4xLaserOnOffInfo | This trap is issued when the When the Laser turns on/off. |