OMNI-gx2litePS-MIB
53 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.23.1 | Nodegx2LitepsDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.23.1 | NodetrapLitepsConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.23.2 | Tablegx2LitepsAnalogTable | not-accessible | mandatory | This table contains gx2Liteps specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.23.2 | NodetrapLitepsConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.23.2.1 | Rowgx2LitepsAnalogEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.1 | Columngx2LitepsAnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.2 | Columnlitepslabel12Volt | read-only | optional | The value of this object provides the label of the 12 Volt Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.3 | Columnlitepsuom12Volt | read-only | optional | The value of this object provides the unit of measure of the 12 Volt Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.4 | ColumnlitepsmajorHigh12Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an I… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.5 | ColumnlitepsmajorLow12Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.6 | ColumnlitepsminorHigh12Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an I… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.7 | ColumnlitepsminorLow12Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.8 | ColumnlitepscurrentValue12Volt | read-only | mandatory | The value of this object provides the Current value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bi… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.9 | ColumnlitepsstateFlag12Volt | read-only | mandatory | The value of this object provides the state of the 12 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.10 | ColumnlitepsminValue12Volt | read-only | mandatory | The value of this object provides the minimum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an I… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.11 | ColumnlitepsmaxValue12Volt | read-only | mandatory | The value of this object provides the maximum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an I… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.12 | ColumnlitepsalarmState12Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 12 Volt Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.13 | Columnlitepslabel5Volt | read-only | optional | The value of this object provides the label of the Attenuator Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.14 | Columnlitepsuom5Volt | read-only | optional | The value of this object provides the Unit of Measure of the 5 Volt Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.15 | ColumnlitepsmajorHigh5Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.16 | ColumnlitepsmajorLow5Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEE… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.17 | ColumnlitepsminorHigh5Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.18 | ColumnlitepsminorLow5Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEE… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.19 | ColumnlitepscurrentValue5Volt | read-only | mandatory | The value of this object provides the Current value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.20 | ColumnlitepsstateFlag5Volt | read-only | mandatory | The value of this object provides the state of the 5 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.21 | ColumnlitepsminValue5Volt | read-only | mandatory | The value of this object provides the minimum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.22 | ColumnlitepsmaxValue5Volt | read-only | mandatory | The value of this object provides the maximum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.23 | ColumnlitepsalarmState5Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 5 Volt Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.24 | Columnlitepslabel3Volt | read-only | optional | The value of this object provides the label of the 3 Anode Volt Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.25 | Columnlitepsuom3Volt | read-only | optional | The value of this object provides the Unit of Measure of the 3.7V anode voltage analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.26 | ColumnlitepsmajorHigh3Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.27 | ColumnlitepsmajorLow3Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.28 | ColumnlitepsminorHigh3Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.29 | ColumnlitepsminorLow3Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.30 | ColumnlitepscurrentValue3Volt | read-only | mandatory | The value of this object provides the Current value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.31 | ColumnlitepsstateFlag3Volt | read-only | mandatory | The value of this object provides the state of the 3 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.32 | ColumnlitepsminValue3Volt | read-only | mandatory | The value of this object provides the minimum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.33 | ColumnlitepsmaxValue3Volt | read-only | mandatory | The value of this object provides the maximum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.23.2.1.34 | ColumnlitepsalarmState3Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 3.7V anode voltage analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.3 | Tablegx2LitepsStatusTable | not-accessible | mandatory | This table contains gx2Liteps specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.23.3 | NodetrapLitepsFanCurrent1 | This trap is issued when Fan 1 is in an alarm condition. | ||
| 1.3.6.1.4.1.1166.6.1.2.23.3.2 | Rowgx2LitepsStatusEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.23.3.2.1 | Columngx2LitepsStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.23.3.2.2 | ColumnlitepslabelFan1Status | read-only | optional | The value of this object provides the label of the Fan 1 Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.3.2.3 | ColumnlitepsvalueFan1Status | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.23.3.2.4 | ColumnlitepsstateflagFan1Status | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.23.3.2.5 | ColumnlitepslabelFan2Status | read-only | optional | The value of this object provides the label of the Fan 2 Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.23.3.2.6 | ColumnlitepsvalueFan2Status | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.23.3.2.7 | ColumnlitepsstateflagFan2Status | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.23.4 | NodetrapLitepsFanCurrent2 | This trap is issued when Fan 2 is in an alarm condition. | ||
| 1.3.6.1.4.1.1166.6.1.2.23.5 | NodetrapLiteps12Volt | This trap is issued when the 12 Volts is in an alarm condition. | ||
| 1.3.6.1.4.1.1166.6.1.2.23.6 | NodetrapLiteps5Volt | This trap is issued when the 5.1 Volts is in an alarm condition. | ||
| 1.3.6.1.4.1.1166.6.1.2.23.7 | NodetrapLiteps3Volt | This trap is issued when the 3.7 Volts is in an alarm condition. |