OMNI-gx2oa100bd-MIB
260 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.17.1 | Nodegx2OA100BDDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.17.1 | NodetrapOA100BDConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.17.2 | Tablegx2OA100BDAnalogTable | not-accessible | mandatory | This table contains gx2OA100B specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.17.2 | NodetrapOA100BDConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.17.2.1 | Rowgx2OA100BDAnalogEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.1 | Columngx2OA100BDAnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.2 | Columnoa100bdlabelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.3 | Columnoa100bduomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.4 | Columnoa100bdmajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.5 | Columnoa100bdmajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.6 | Columnoa100bdminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.7 | Columnoa100bdminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.8 | Columnoa100bdcurrentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.9 | Columnoa100bdstateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.10 | Columnoa100bdminValueModTemp | read-only | mandatory | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.11 | Columnoa100bdmaxValueModTemp | read-only | mandatory | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.12 | Columnoa100bdalarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.13 | Columnoa100bdlabelOptInPower | read-only | optional | The value of this object provides the label of the Optical Input Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.14 | Columnoa100bduomOptInPower | read-only | optional | The value of this object provides the Unit of Measure of the Optical Input Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.15 | Columnoa100bdmajorHighOptInPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.16 | Columnoa100bdmajorLowOptInPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.17 | Columnoa100bdminorHighOptInPower | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.18 | Columnoa100bdminorLowOptInPower | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.19 | Columnoa100bdcurrentValueOptInPower | read-only | mandatory | The value of this object provides the Current value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.20 | Columnoa100bdstateFlagOptInPower | read-only | mandatory | The value of this object provides the state of the Optical Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.21 | Columnoa100bdminValueOptInPower | read-only | mandatory | The value of this object provides the minimum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.22 | Columnoa100bdmaxValueOptInPower | read-only | mandatory | The value of this object provides the maximum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.23 | Columnoa100bdalarmStateOptInPower | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Input Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.24 | Columnoa100bdlabelOptOutPower | read-only | optional | The value of this object provides the label of the Optical Output Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.25 | Columnoa100bduomOptOutPower | read-only | optional | The value of this object provides the Unit of Measure of the Optical Output Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.26 | Columnoa100bdmajorHighOptOutPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.27 | Columnoa100bdmajorLowOptOutPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.28 | Columnoa100bdminorHighOptOutPower | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.29 | Columnoa100bdminorLowOptOutPower | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.30 | Columnoa100bdcurrentValueOptOutPower | read-only | mandatory | The value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.31 | Columnoa100bdstateFlagOptOutPower | read-only | mandatory | The value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.32 | Columnoa100bdminValueOptOutPower | read-only | mandatory | The value of this object provides the minimum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.33 | Columnoa100bdmaxValueOptOutPower | read-only | mandatory | The value of this object provides the maximum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.34 | Columnoa100bdalarmStateOptOutPower | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Output Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.35 | Columnoa100bdlabelMainTECTemp | read-only | optional | The value of this object provides the label of the TEC Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.36 | Columnoa100bduomMainTECTemp | read-only | optional | The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.37 | Columnoa100bdmajorHighMainTECTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.38 | Columnoa100bdmajorLowMainTECTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.39 | Columnoa100bdminorHighMainTECTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.40 | Columnoa100bdminorLowMainTECTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.41 | Columnoa100bdcurrentValueMainTECTemp | read-only | mandatory | The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.42 | Columnoa100bdstateFlagMainTECTemp | read-only | mandatory | The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.43 | Columnoa100bdminValueMainTECTemp | read-only | mandatory | The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.44 | Columnoa100bdmaxValueMainTECTemp | read-only | mandatory | The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.45 | Columnoa100bdalarmStateMainTECTemp | read-only | mandatory | The value of this object provides the curent alarm state of the TEC Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.46 | Columnoa100bdlabelMainLaserPower | read-only | optional | The value of this object provides the label of the Main Laser Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.47 | Columnoa100bduomMainLaserPower | read-only | optional | The value of this object provides the Unit of Measure of the Main Laser Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.48 | Columnoa100bdmajorHighMainLaserPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.49 | Columnoa100bdmajorLowMainLaserPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.50 | Columnoa100bdminorHighMainLaserPower | read-only | mandatory | The value of this object provides the Minor High alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.51 | Columnoa100bdminorLowMainLaserPower | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.52 | Columnoa100bdcurrentValueMainLaserPower | read-only | mandatory | The value of this object provides the Current value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an I… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.53 | Columnoa100bdstateFlagMainLaserPower | read-only | mandatory | The value of this object provides the state of the Main Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.54 | Columnoa100bdminValueMainLaserPower | read-only | mandatory | The value of this object provides the minimum value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an I… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.55 | Columnoa100bdmaxValueMainLaserPower | read-only | mandatory | The value of this object provides the maximum value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an I… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.56 | Columnoa100bdalarmStateMainLaserPower | read-only | mandatory | The value of this object provides the curent alarm state of the Main Laser Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.57 | Columnoa100bdlabelAuxTECTemp | read-only | optional | The value of this object provides the label of the TEC Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.58 | Columnoa100bduomAuxTECTemp | read-only | optional | The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.59 | Columnoa100bdmajorHighAuxTECTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.60 | Columnoa100bdmajorLowAuxTECTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.61 | Columnoa100bdminorHighAuxTECTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.62 | Columnoa100bdminorLowAuxTECTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.63 | Columnoa100bdcurrentValueAuxTECTemp | read-only | mandatory | The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.64 | Columnoa100bdstateFlagAuxTECTemp | read-only | mandatory | The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.65 | Columnoa100bdminValueAuxTECTemp | read-only | mandatory | The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.66 | Columnoa100bdmaxValueAuxTECTemp | read-only | mandatory | The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.67 | Columnoa100bdalarmStateAuxTECTemp | read-only | mandatory | The value of this object provides the curent alarm state of the TEC Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.68 | Columnoa100bdlabelAuxLaserPower | read-only | optional | The value of this object provides the label of the Aux Laser Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.69 | Columnoa100bduomAuxLaserPower | read-only | optional | The value of this object provides the Unit of Measure of the Aux Laser Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.70 | Columnoa100bdmajorHighAuxLaserPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.71 | Columnoa100bdmajorLowAuxLaserPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.72 | Columnoa100bdminorHighAuxLaserPower | read-only | mandatory | The value of this object provides the Minor High alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.73 | Columnoa100bdminorLowAuxLaserPower | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.74 | Columnoa100bdcurrentValueAuxLaserPower | read-only | mandatory | The value of this object provides the Current value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.75 | Columnoa100bdstateFlagAuxLaserPower | read-only | mandatory | The value of this object provides the state of the Aux Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.76 | Columnoa100bdminValueAuxLaserPower | read-only | mandatory | The value of this object provides the minimum value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.77 | Columnoa100bdmaxValueAuxLaserPower | read-only | mandatory | The value of this object provides the maximum value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IE… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.78 | Columnoa100bdalarmStateAuxLaserPower | read-only | mandatory | The value of this object provides the curent alarm state of the Aux Laser Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.79 | Columnoa100bdlabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.80 | Columnoa100bduomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.81 | Columnoa100bdmajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.82 | Columnoa100bdmajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.83 | Columnoa100bdminorHighFanCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.84 | Columnoa100bdminorLowFanCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.85 | Columnoa100bdcurrentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.86 | Columnoa100bdstateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.87 | Columnoa100bdminValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.88 | Columnoa100bdmaxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.89 | Columnoa100bdalarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.90 | Columnoa100bdlabelOPSetting | read-only | optional | The value of this object provides the label of the Output Power Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.91 | Columnoa100bduomOPSetting | read-only | optional | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.92 | Columnoa100bdmajorHighOPSetting | read-only | mandatory | The value of this object provides the Major High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.93 | Columnoa100bdmajorLowOPSetting | read-only | mandatory | The value of this object provides the Major Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.94 | Columnoa100bdminorHighOPSetting | read-only | mandatory | The value of this object provides the Minor High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.95 | Columnoa100bdminorLowOPSetting | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.96 | Columnoa100bdcurrentValueOPSetting | read-write | mandatory | The value of this object provides the Current value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.97 | Columnoa100bdstateFlagOPSetting | read-only | mandatory | The value of this object provides the state of the Output Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.98 | Columnoa100bdminValueOPSetting | read-only | mandatory | The value of this object provides the minimum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.99 | Columnoa100bdmaxValueOPSetting | read-only | mandatory | The value of this object provides the maximum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.100 | Columnoa100bdalarmStateOPSetting | read-only | mandatory | The value of this object provides the curent alarm state of the Output Power Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.101 | Columnoa100bdlabelLPSetting | read-only | optional | The value of this object provides the label of the Laser Power Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.102 | Columnoa100bduomLPSetting | read-only | optional | The value of this object provides the Unit of Measure of the Laser Power Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.103 | Columnoa100bdmajorHighLPSetting | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.104 | Columnoa100bdmajorLowLPSetting | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.105 | Columnoa100bdminorHighLPSetting | read-only | mandatory | The value of this object provides the Minor High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.106 | Columnoa100bdminorLowLPSetting | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.107 | Columnoa100bdcurrentValueLPSetting | read-write | mandatory | The value of this object provides the Current value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.108 | Columnoa100bdstateFlagLPSetting | read-only | mandatory | The value of this object provides the state of the Laser Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.109 | Columnoa100bdminValueLPSetting | read-only | mandatory | The value of this object provides the minimum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.110 | Columnoa100bdmaxValueLPSetting | read-only | mandatory | The value of this object provides the maximum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.111 | Columnoa100bdalarmStateLPSetting | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Power Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.112 | Columnoa100bdlabelCGSetting | read-only | optional | The value of this object provides the label of the Constant Gain Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.113 | Columnoa100bduomCGSetting | read-only | optional | The value of this object provides the Unit of Measure of the Constant Gain Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.114 | Columnoa100bdmajorHighCGSetting | read-only | mandatory | The value of this object provides the Major High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is repre… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.115 | Columnoa100bdmajorLowCGSetting | read-only | mandatory | The value of this object provides the Major Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.116 | Columnoa100bdminorHighCGSetting | read-only | mandatory | The value of this object provides the Minor High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is repre… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.117 | Columnoa100bdminorLowCGSetting | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.118 | Columnoa100bdcurrentValueCGSetting | read-write | mandatory | The value of this object provides the Current value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.119 | Columnoa100bdstateFlagCGSetting | read-only | mandatory | The value of this object provides the state of the Constant Gain Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.120 | Columnoa100bdminValueCGSetting | read-only | mandatory | The value of this object provides the minimum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.121 | Columnoa100bdmaxValueCGSetting | read-only | mandatory | The value of this object provides the maximum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.122 | Columnoa100bdalarmStateCGSetting | read-only | mandatory | The value of this object provides the curent alarm state of the Constant Gain Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.123 | Columnoa100bdlabelOptThreshold | read-only | optional | The value of this object provides the label of the Optical Input Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.124 | Columnoa100bduomOptThreshold | read-only | optional | The value of this object provides the Unit of Measure of the Optical Input Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.125 | Columnoa100bdmajorHighOptThreshold | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.126 | Columnoa100bdmajorLowOptThreshold | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is repr… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.127 | Columnoa100bdminorHighOptThreshold | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.128 | Columnoa100bdminorLowOptThreshold | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is repr… |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.129 | Columnoa100bdcurrentValueOptThreshold | read-write | mandatory | The value of this object provides the Current value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.130 | Columnoa100bdstateFlagOptThreshold | read-only | mandatory | The value of this object provides the state of the Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.131 | Columnoa100bdminValueOptThreshold | read-only | mandatory | The value of this object provides the minimum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.132 | Columnoa100bdmaxValueOptThreshold | read-only | mandatory | The value of this object provides the maximum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.17.2.1.133 | Columnoa100bdalarmStateOptThreshold | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Input Threshold Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.3 | Tablegx2OA100BDDigitalTable | not-accessible | mandatory | This table contains gx2OA100B specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.17.3 | NodetrapOA100BDModuleTemperatureAlarm | This trap is issued when the OA100B Module's Temperature goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.3.2 | Rowgx2OA100BDDigitalEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.1 | Columngx2OA100BDDigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.2 | Columnoa100bdlabelModeSetting | read-only | optional | The value of this object provides the label of the OA100BD's Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.3 | Columnoa100bdenumModeSetting | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.4 | Columnoa100bdvalueModeSetting | read-write | mandatory | The value of this object is the current value of the parameter. It is an integer value from 0 to 5 representing the operation mode of the module. |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.5 | Columnoa100bdstateFlagModeSetting | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.6 | Columnoa100bdlabelModuleState | read-only | optional | The value of this object provides the label of the Module State Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.7 | Columnoa100bdenumModuleState | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.8 | Columnoa100bdvalueModuleState | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.9 | Columnoa100bdstateFlagModuleState | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.10 | Columnoa100bdlabelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.11 | Columnoa100bdenumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.12 | Columnoa100bdvalueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.3.2.13 | Columnoa100bdstateFlagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4 | Tablegx2OA100BDStatusTable | not-accessible | mandatory | This table contains gx2OA100B specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.17.4 | NodetrapOA100BDOpticalInPowerAlarm | This trap is issued when the input Optical Input Power parameter goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.4.3 | Rowgx2OA100BDStatusEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.1 | Columngx2OA100BDStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.2 | Columnoa100bdlabelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.3 | Columnoa100bdvalueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.4 | Columnoa100bdstateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.5 | Columnoa100bdlabelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.6 | Columnoa100bdvalueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.7 | Columnoa100bdstateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.8 | Columnoa100bdlabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.9 | Columnoa100bdvalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.10 | Columnoa100bdstateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.11 | Columnoa100bdlabelAlarmDataCRC | read-only | optional | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.12 | Columnoa100bdvalueAlarmDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.13 | Columnoa100bdstateflagAlarmDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.14 | Columnoa100bdlabelCalibrationDataCRC | read-only | optional | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.15 | Columnoa100bdvalueCalibrationDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.16 | Columnoa100bdstateflagCalibrationDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.17 | Columnoa100bdlabelOptInShutdown | read-only | optional | The value of this object provides the label of the Optical Input Power Shutdown Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.18 | Columnoa100bdvalueOptInShutdown | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.19 | Columnoa100bdstateflagOptInShutdown | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.20 | Columnoa100bdlabelMainTECTempShutdown | read-only | optional | The value of this object provides the label of the Main TEC Temperature Shutdown Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.21 | Columnoa100bdvalueMainTECTempShutdown | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.22 | Columnoa100bdstateflagMainTECTempShutdown | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.23 | Columnoa100bdlabelAuxTECTempShutdown | read-only | optional | The value of this object provides the label of the Aux TEC Temperature Shutdown Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.24 | Columnoa100bdvalueAuxTECTempShutdown | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.25 | Columnoa100bdstateflagAuxTECTempShutdown | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.26 | Columnoa100bdlabelPowerFail | read-only | optional | The value of this object provides the label of the Power Supply Fail Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.27 | Columnoa100bdvaluePowerFail | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.28 | Columnoa100bdstateflagPowerFail | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.29 | Columnoa100bdlabelKeySwitch | read-only | optional | The value of this object provides the label of the Key Switch Setting Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.30 | Columnoa100bdvalueKeySwitch | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.31 | Columnoa100bdstateflagKeySwitch | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.32 | Columnoa100bdlabelMainLaserCurrShutdown | read-only | optional | The value of this object provides the label of the Main Laser Current Shutdown Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.33 | Columnoa100bdvalueMainLaserCurrShutdown | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.34 | Columnoa100bdstateflagMainLaserCurrShutdown | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.35 | Columnoa100bdlabelAuxLaserCurrShutdown | read-only | optional | The value of this object provides the label of the AuxLaser Current Shutdown Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.36 | Columnoa100bdvalueAuxLaserCurrShutdown | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.37 | Columnoa100bdstateflagAuxLaserCurrShutdown | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.38 | Columnoa100bdlabelMainLaserPowShutdown | read-only | optional | The value of this object provides the label of the Main Laser Power Shutdown Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.39 | Columnoa100bdvalueMainLaserPowShutdown | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.40 | Columnoa100bdstateflagMainLaserPowShutdown | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.41 | Columnoa100bdlabelAuxLaserPowShutdown | read-only | optional | The value of this object provides the label of the Aux Laser Power Shutdown Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.42 | Columnoa100bdvalueAuxLaserPowShutdown | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.43 | Columnoa100bdstateflagAuxLaserPowShutdown | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.44 | Columnoa100bdlabelADCStatus | read-only | optional | The value of this object provides the label of the ADC Operation Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.45 | Columnoa100bdvalueADCStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.46 | Columnoa100bdstateflagADCStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.47 | Columnoa100bdlabelConstGainStatus | read-only | optional | The value of this object provides the label of the Constant Gain Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.48 | Columnoa100bdvalueConstGainStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.49 | Columnoa100bdstateflagConstGainStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.50 | Columnoa100bdlabelHardwareErrorStatus | read-only | optional | The value of this object provides the label of the Hardware Error Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.51 | Columnoa100bdvalueHardwareErrorStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.52 | Columnoa100bdstateflagHardwareErrorStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.53 | Columnoa100bdlabelStandbyStatus | read-only | optional | The value of this object provides the label of the Standby Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.54 | Columnoa100bdvalueStandbyStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.17.4.3.55 | Columnoa100bdstateflagStandbyStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.17.5 | Tablegx2OA100BDFactoryTable | not-accessible | mandatory | This table contains gx2OA100B specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.17.5 | NodetrapOA100BDOpticalOutPowerAlarm | This trap is issued when the input Optical Output Power parameter goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.5.4 | Rowgx2OA100BDFactoryEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.1 | Columngx2OA100BDFactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.2 | Columnoa100bdbootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. Boot Control Byte bit definition as follows : bit 0 : boot bit (0=boot… |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.3 | Columnoa100bdbootStatusByte | read-only | mandatory | This object indicates the status of the last boot Boot Status Byte bit definitions as follows: bit 0 : bank 0 status (0=bank is OK or not used, 1=bank failed b… |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.4 | Columnoa100bdbank0CRC | read-only | mandatory | This object provides the CRC code of bank 0. The value is best displayed in Hex format |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.5 | Columnoa100bdbank1CRC | read-only | mandatory | This object provides the CRC code of bank 1. The value is best displayed in Hex format |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.6 | Columnoa100bdprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed programmed EEPROM byte definitions as follows: 0xBB = EEPROM is programmed 0xDB = EEPROM is being resto… |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.7 | Columnoa100bdfactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. The value is best displayed in Hex format |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.8 | Columnoa100bdcalculateCRC | read-only | obsolete | This object indicates which of the Emnums will have the CRC calculated. Calculate CRC command defintions as follows : 0x00 : recalculate factory data CRC 0x01 … |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.9 | Columnoa100bdhourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.10 | Columnoa100bdflashPrgCntA | read-only | mandatory | This object provides the number of times the flash has been programmed on side A. |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.11 | Columnoa100bdflashPrgCntB | read-only | mandatory | This object provides the number of times the flash has been programmed on side B. |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.12 | Columnoa100bdfwRev0 | read-only | mandatory | This object provides the Revision of the firmware stores in bank 0. This value should be displayed as two ascii characters. |
| 1.3.6.1.4.1.1166.6.1.2.17.5.4.13 | Columnoa100bdfwRev1 | read-only | mandatory | This object provides the Revision of the firmware stores in bank 1. This value should be displayed as two ascii characters. |
| 1.3.6.1.4.1.1166.6.1.2.17.6 | Tablegx2OA100BDHoldTimeTable | not-accessible | mandatory | This table contains gx2OA100BD specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.17.6 | NodetrapOA100BDMainTECTemperatureAlarm | This trap is issued when the OA100B Main TEC Temperature goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.6.5 | Rowgx2OA100BDHoldTimeEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.17.6.5.1 | Columngx2OA100BDHoldTimeTableIndex | read-only | mandatory | The value of this object is the index of the data object. |
| 1.3.6.1.4.1.1166.6.1.2.17.6.5.2 | Columngx2OA100BDHoldTimeSpecIndex | read-only | mandatory | The value of this object identifies the index of the alarm object to be modified. |
| 1.3.6.1.4.1.1166.6.1.2.17.6.5.3 | Columngx2OA100BDHoldTimeData | read-write | mandatory | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered… |
| 1.3.6.1.4.1.1166.6.1.2.17.7 | NodetrapOA100BDMainLaserPowerAlarm | This trap is issued when the OA100B Main Laser Power goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.8 | NodetrapOA100BDAuxTECTemperatureAlarm | This trap is issued when the OA100B Aux TEC Temperature goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.9 | NodetrapOA100BDAuxLaserPowerAlarm | This trap is issued when the OA100B Aux Laser Power goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.10 | NodetrapOA100BDFanCurrentAlarm | This trap is issued when the OA100B Module's Fan Currrent parameter goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.11 | NodetrapOA100BDResetFacDefault | This trap is issued when the OA100B resets to factory defaults | ||
| 1.3.6.1.4.1.1166.6.1.2.17.12 | NodetrapOA100BDStandbyMode | This trap is issued when the OA100B is in Standby Mode. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.13 | NodetrapOA100BDOptInShutdown | This trap is issued when the OA100B is in Optical Input Shutdown. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.14 | NodetrapOA100BDMainTECTempShutdown | This trap is issued when the OA100B is in Main TEC Temperature Shutdown. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.15 | NodetrapOA100BDAuxTECTempShutdown | This trap is issued when the OA100B is in Aux TEC Temperature Shutdown. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.16 | NodetrapOA100BDKeySwitch | This trap is issued when the Key Switch disables the OA100B. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.17 | NodetrapOA100BDPowerFail | This trap is issued when there is an OA100B Power Supply Failure. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.18 | NodetrapOA100BDMainLasCurrShutdown | This trap is issued when the OA100B is in Main Laser Current Shutdown. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.19 | NodetrapOA100BDAuxLasCurrShutdown | This trap is issued when the OA100B is in Aux Laser Current Shutdown. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.20 | NodetrapOA100BDMainLasPowerShutdown | This trap is issued when the OA100B is in Main Laser Power Shutdown. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.21 | NodetrapOA100BDAuxLasPowerShutdown | This trap is issued when the OA100B is in Aux Laser Power Shutdown. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.22 | NodetrapOA100BDInvalidMode | This trap is issued when the OA100B is in an invalid mode. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.23 | NodetrapOA100BDFlashAlarm | This trap is issued when the OA100B Module's boot or flash programming sequence has detected a Flash error. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.24 | NodetrapOA100BDBoot0Alarm | This trap is issued when the OA100B Module's Bank 0 Boot sequence has detected an error. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.25 | NodetrapOA100BDBoot1Alarm | This trap is issued when the OA100B Module's Bank 1 Boot sequence has detected an error. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.26 | NodetrapOA100BDAlarmDataCRCAlarm | This trap is issued when the OA100B Module detects an error calculating the alarm limit CRC. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.27 | NodetrapOA100BDFactoryDataCRCAlarm | This trap is issued when the OA100B Module detects an error calculating the Factory data CRC. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.28 | NodetrapOA100BDCalDataCRCAlarm | This trap is issued when the OA100B Module detects an error calculating the Calibration data CRC. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.29 | NodetrapOA100BDFacCalFloatAlarm | This trap is issued when the OA100B Module detects factory calibration float data alarm. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.30 | NodetrapOA100BDOptInThreshAlarm | This trap is issued when the OA100B Module Optical Input drops below the user set threshold. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.31 | NodetrapOA100BDGainErrorAlarm | This trap is issued when the OA100B Module can not produce the desired user set gain in Constant Gain Set Mode. | ||
| 1.3.6.1.4.1.1166.6.1.2.17.32 | NodetrapOA100BDHardwareErrorAlarm | This trap is issued when any of the OA100BD Module's TEC,Laser, +12V, or +3.7V current parameters go out of range. |