MIB Viewer

OMNI-gx2oa100bd-MIB

260 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.17.1Nodegx2OA100BDDescriptor
1.3.6.1.4.1.1166.6.1.2.17.1NodetrapOA100BDConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.17.2Tablegx2OA100BDAnalogTablenot-accessiblemandatoryThis table contains gx2OA100B specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.17.2NodetrapOA100BDConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.17.2.1Rowgx2OA100BDAnalogEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.17.2.1.1Columngx2OA100BDAnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.17.2.1.2Columnoa100bdlabelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.3Columnoa100bduomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.4Columnoa100bdmajorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.17.2.1.5Columnoa100bdmajorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.17.2.1.6Columnoa100bdminorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.17.2.1.7Columnoa100bdminorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.17.2.1.8Columnoa100bdcurrentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.17.2.1.9Columnoa100bdstateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.10Columnoa100bdminValueModTempread-onlymandatoryThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.17.2.1.11Columnoa100bdmaxValueModTempread-onlymandatoryThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.17.2.1.12Columnoa100bdalarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.13Columnoa100bdlabelOptInPowerread-onlyoptionalThe value of this object provides the label of the Optical Input Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.14Columnoa100bduomOptInPowerread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Input Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.15Columnoa100bdmajorHighOptInPowerread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.17.2.1.16Columnoa100bdmajorLowOptInPowerread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.17.2.1.17Columnoa100bdminorHighOptInPowerread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.17.2.1.18Columnoa100bdminorLowOptInPowerread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.17.2.1.19Columnoa100bdcurrentValueOptInPowerread-onlymandatoryThe value of this object provides the Current value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.17.2.1.20Columnoa100bdstateFlagOptInPowerread-onlymandatoryThe value of this object provides the state of the Optical Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.21Columnoa100bdminValueOptInPowerread-onlymandatoryThe value of this object provides the minimum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.17.2.1.22Columnoa100bdmaxValueOptInPowerread-onlymandatoryThe value of this object provides the maximum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.17.2.1.23Columnoa100bdalarmStateOptInPowerread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Input Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.24Columnoa100bdlabelOptOutPowerread-onlyoptionalThe value of this object provides the label of the Optical Output Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.25Columnoa100bduomOptOutPowerread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Output Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.26Columnoa100bdmajorHighOptOutPowerread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.17.2.1.27Columnoa100bdmajorLowOptOutPowerread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.17.2.1.28Columnoa100bdminorHighOptOutPowerread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.17.2.1.29Columnoa100bdminorLowOptOutPowerread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.17.2.1.30Columnoa100bdcurrentValueOptOutPowerread-onlymandatoryThe value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.17.2.1.31Columnoa100bdstateFlagOptOutPowerread-onlymandatoryThe value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.32Columnoa100bdminValueOptOutPowerread-onlymandatoryThe value of this object provides the minimum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.17.2.1.33Columnoa100bdmaxValueOptOutPowerread-onlymandatoryThe value of this object provides the maximum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.17.2.1.34Columnoa100bdalarmStateOptOutPowerread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Output Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.35Columnoa100bdlabelMainTECTempread-onlyoptionalThe value of this object provides the label of the TEC Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.36Columnoa100bduomMainTECTempread-onlyoptionalThe value of this object provides the Unit of Measure of the TEC Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.37Columnoa100bdmajorHighMainTECTempread-onlymandatoryThe value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.17.2.1.38Columnoa100bdmajorLowMainTECTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.17.2.1.39Columnoa100bdminorHighMainTECTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.17.2.1.40Columnoa100bdminorLowMainTECTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.17.2.1.41Columnoa100bdcurrentValueMainTECTempread-onlymandatoryThe value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.17.2.1.42Columnoa100bdstateFlagMainTECTempread-onlymandatoryThe value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.43Columnoa100bdminValueMainTECTempread-onlymandatoryThe value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.17.2.1.44Columnoa100bdmaxValueMainTECTempread-onlymandatoryThe value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.17.2.1.45Columnoa100bdalarmStateMainTECTempread-onlymandatoryThe value of this object provides the curent alarm state of the TEC Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.46Columnoa100bdlabelMainLaserPowerread-onlyoptionalThe value of this object provides the label of the Main Laser Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.47Columnoa100bduomMainLaserPowerread-onlyoptionalThe value of this object provides the Unit of Measure of the Main Laser Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.48Columnoa100bdmajorHighMainLaserPowerread-onlymandatoryThe value of this object provides the Major High alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.17.2.1.49Columnoa100bdmajorLowMainLaserPowerread-onlymandatoryThe value of this object provides the Major Low alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.17.2.1.50Columnoa100bdminorHighMainLaserPowerread-onlymandatoryThe value of this object provides the Minor High alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.17.2.1.51Columnoa100bdminorLowMainLaserPowerread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.17.2.1.52Columnoa100bdcurrentValueMainLaserPowerread-onlymandatoryThe value of this object provides the Current value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an I…
1.3.6.1.4.1.1166.6.1.2.17.2.1.53Columnoa100bdstateFlagMainLaserPowerread-onlymandatoryThe value of this object provides the state of the Main Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.54Columnoa100bdminValueMainLaserPowerread-onlymandatoryThe value of this object provides the minimum value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an I…
1.3.6.1.4.1.1166.6.1.2.17.2.1.55Columnoa100bdmaxValueMainLaserPowerread-onlymandatoryThe value of this object provides the maximum value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an I…
1.3.6.1.4.1.1166.6.1.2.17.2.1.56Columnoa100bdalarmStateMainLaserPowerread-onlymandatoryThe value of this object provides the curent alarm state of the Main Laser Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.57Columnoa100bdlabelAuxTECTempread-onlyoptionalThe value of this object provides the label of the TEC Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.58Columnoa100bduomAuxTECTempread-onlyoptionalThe value of this object provides the Unit of Measure of the TEC Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.59Columnoa100bdmajorHighAuxTECTempread-onlymandatoryThe value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.17.2.1.60Columnoa100bdmajorLowAuxTECTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.17.2.1.61Columnoa100bdminorHighAuxTECTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.17.2.1.62Columnoa100bdminorLowAuxTECTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.17.2.1.63Columnoa100bdcurrentValueAuxTECTempread-onlymandatoryThe value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.17.2.1.64Columnoa100bdstateFlagAuxTECTempread-onlymandatoryThe value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.65Columnoa100bdminValueAuxTECTempread-onlymandatoryThe value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.17.2.1.66Columnoa100bdmaxValueAuxTECTempread-onlymandatoryThe value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.17.2.1.67Columnoa100bdalarmStateAuxTECTempread-onlymandatoryThe value of this object provides the curent alarm state of the TEC Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.68Columnoa100bdlabelAuxLaserPowerread-onlyoptionalThe value of this object provides the label of the Aux Laser Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.69Columnoa100bduomAuxLaserPowerread-onlyoptionalThe value of this object provides the Unit of Measure of the Aux Laser Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.70Columnoa100bdmajorHighAuxLaserPowerread-onlymandatoryThe value of this object provides the Major High alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.17.2.1.71Columnoa100bdmajorLowAuxLaserPowerread-onlymandatoryThe value of this object provides the Major Low alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.17.2.1.72Columnoa100bdminorHighAuxLaserPowerread-onlymandatoryThe value of this object provides the Minor High alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.17.2.1.73Columnoa100bdminorLowAuxLaserPowerread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.17.2.1.74Columnoa100bdcurrentValueAuxLaserPowerread-onlymandatoryThe value of this object provides the Current value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.17.2.1.75Columnoa100bdstateFlagAuxLaserPowerread-onlymandatoryThe value of this object provides the state of the Aux Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.76Columnoa100bdminValueAuxLaserPowerread-onlymandatoryThe value of this object provides the minimum value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.17.2.1.77Columnoa100bdmaxValueAuxLaserPowerread-onlymandatoryThe value of this object provides the maximum value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IE…
1.3.6.1.4.1.1166.6.1.2.17.2.1.78Columnoa100bdalarmStateAuxLaserPowerread-onlymandatoryThe value of this object provides the curent alarm state of the Aux Laser Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.79Columnoa100bdlabelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.80Columnoa100bduomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.81Columnoa100bdmajorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.17.2.1.82Columnoa100bdmajorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.17.2.1.83Columnoa100bdminorHighFanCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.17.2.1.84Columnoa100bdminorLowFanCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.17.2.1.85Columnoa100bdcurrentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.17.2.1.86Columnoa100bdstateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.87Columnoa100bdminValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.17.2.1.88Columnoa100bdmaxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.17.2.1.89Columnoa100bdalarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.90Columnoa100bdlabelOPSettingread-onlyoptionalThe value of this object provides the label of the Output Power Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.91Columnoa100bduomOPSettingread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.92Columnoa100bdmajorHighOPSettingread-onlymandatoryThe value of this object provides the Major High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.17.2.1.93Columnoa100bdmajorLowOPSettingread-onlymandatoryThe value of this object provides the Major Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.17.2.1.94Columnoa100bdminorHighOPSettingread-onlymandatoryThe value of this object provides the Minor High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.17.2.1.95Columnoa100bdminorLowOPSettingread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.17.2.1.96Columnoa100bdcurrentValueOPSettingread-writemandatoryThe value of this object provides the Current value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.17.2.1.97Columnoa100bdstateFlagOPSettingread-onlymandatoryThe value of this object provides the state of the Output Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.98Columnoa100bdminValueOPSettingread-onlymandatoryThe value of this object provides the minimum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.17.2.1.99Columnoa100bdmaxValueOPSettingread-onlymandatoryThe value of this object provides the maximum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.17.2.1.100Columnoa100bdalarmStateOPSettingread-onlymandatoryThe value of this object provides the curent alarm state of the Output Power Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.101Columnoa100bdlabelLPSettingread-onlyoptionalThe value of this object provides the label of the Laser Power Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.102Columnoa100bduomLPSettingread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser Power Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.103Columnoa100bdmajorHighLPSettingread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.17.2.1.104Columnoa100bdmajorLowLPSettingread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.17.2.1.105Columnoa100bdminorHighLPSettingread-onlymandatoryThe value of this object provides the Minor High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.17.2.1.106Columnoa100bdminorLowLPSettingread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.17.2.1.107Columnoa100bdcurrentValueLPSettingread-writemandatoryThe value of this object provides the Current value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.17.2.1.108Columnoa100bdstateFlagLPSettingread-onlymandatoryThe value of this object provides the state of the Laser Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.109Columnoa100bdminValueLPSettingread-onlymandatoryThe value of this object provides the minimum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.17.2.1.110Columnoa100bdmaxValueLPSettingread-onlymandatoryThe value of this object provides the maximum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.17.2.1.111Columnoa100bdalarmStateLPSettingread-onlymandatoryThe value of this object provides the curent alarm state of the Laser Power Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.112Columnoa100bdlabelCGSettingread-onlyoptionalThe value of this object provides the label of the Constant Gain Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.113Columnoa100bduomCGSettingread-onlyoptionalThe value of this object provides the Unit of Measure of the Constant Gain Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.114Columnoa100bdmajorHighCGSettingread-onlymandatoryThe value of this object provides the Major High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is repre…
1.3.6.1.4.1.1166.6.1.2.17.2.1.115Columnoa100bdmajorLowCGSettingread-onlymandatoryThe value of this object provides the Major Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.17.2.1.116Columnoa100bdminorHighCGSettingread-onlymandatoryThe value of this object provides the Minor High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is repre…
1.3.6.1.4.1.1166.6.1.2.17.2.1.117Columnoa100bdminorLowCGSettingread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.17.2.1.118Columnoa100bdcurrentValueCGSettingread-writemandatoryThe value of this object provides the Current value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.17.2.1.119Columnoa100bdstateFlagCGSettingread-onlymandatoryThe value of this object provides the state of the Constant Gain Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.120Columnoa100bdminValueCGSettingread-onlymandatoryThe value of this object provides the minimum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.17.2.1.121Columnoa100bdmaxValueCGSettingread-onlymandatoryThe value of this object provides the maximum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.17.2.1.122Columnoa100bdalarmStateCGSettingread-onlymandatoryThe value of this object provides the curent alarm state of the Constant Gain Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.123Columnoa100bdlabelOptThresholdread-onlyoptionalThe value of this object provides the label of the Optical Input Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.124Columnoa100bduomOptThresholdread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Input Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.2.1.125Columnoa100bdmajorHighOptThresholdread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.17.2.1.126Columnoa100bdmajorLowOptThresholdread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is repr…
1.3.6.1.4.1.1166.6.1.2.17.2.1.127Columnoa100bdminorHighOptThresholdread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.17.2.1.128Columnoa100bdminorLowOptThresholdread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is repr…
1.3.6.1.4.1.1166.6.1.2.17.2.1.129Columnoa100bdcurrentValueOptThresholdread-writemandatoryThe value of this object provides the Current value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.17.2.1.130Columnoa100bdstateFlagOptThresholdread-onlymandatoryThe value of this object provides the state of the Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.2.1.131Columnoa100bdminValueOptThresholdread-onlymandatoryThe value of this object provides the minimum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.17.2.1.132Columnoa100bdmaxValueOptThresholdread-onlymandatoryThe value of this object provides the maximum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.17.2.1.133Columnoa100bdalarmStateOptThresholdread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Input Threshold Analog parameter.
1.3.6.1.4.1.1166.6.1.2.17.3Tablegx2OA100BDDigitalTablenot-accessiblemandatoryThis table contains gx2OA100B specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.17.3NodetrapOA100BDModuleTemperatureAlarmThis trap is issued when the OA100B Module's Temperature goes out of range.
1.3.6.1.4.1.1166.6.1.2.17.3.2Rowgx2OA100BDDigitalEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.17.3.2.1Columngx2OA100BDDigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.17.3.2.2Columnoa100bdlabelModeSettingread-onlyoptionalThe value of this object provides the label of the OA100BD's Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.17.3.2.3Columnoa100bdenumModeSettingread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.17.3.2.4Columnoa100bdvalueModeSettingread-writemandatoryThe value of this object is the current value of the parameter. It is an integer value from 0 to 5 representing the operation mode of the module.
1.3.6.1.4.1.1166.6.1.2.17.3.2.5Columnoa100bdstateFlagModeSettingread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.3.2.6Columnoa100bdlabelModuleStateread-onlyoptionalThe value of this object provides the label of the Module State Digital parameter.
1.3.6.1.4.1.1166.6.1.2.17.3.2.7Columnoa100bdenumModuleStateread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.17.3.2.8Columnoa100bdvalueModuleStateread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.17.3.2.9Columnoa100bdstateFlagModuleStateread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.3.2.10Columnoa100bdlabelFactoryDefaultread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.17.3.2.11Columnoa100bdenumFactoryDefaultread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.17.3.2.12Columnoa100bdvalueFactoryDefaultread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.17.3.2.13Columnoa100bdstateFlagFactoryDefaultread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4Tablegx2OA100BDStatusTablenot-accessiblemandatoryThis table contains gx2OA100B specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.17.4NodetrapOA100BDOpticalInPowerAlarmThis trap is issued when the input Optical Input Power parameter goes out of range.
1.3.6.1.4.1.1166.6.1.2.17.4.3Rowgx2OA100BDStatusEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.17.4.3.1Columngx2OA100BDStatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.17.4.3.2Columnoa100bdlabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.3Columnoa100bdvalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.4Columnoa100bdstateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.5Columnoa100bdlabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.6Columnoa100bdvalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.7Columnoa100bdstateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.8Columnoa100bdlabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.9Columnoa100bdvalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.10Columnoa100bdstateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.11Columnoa100bdlabelAlarmDataCRCread-onlyoptionalThe value of this object provides the label of the Alarm Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.12Columnoa100bdvalueAlarmDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.13Columnoa100bdstateflagAlarmDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.14Columnoa100bdlabelCalibrationDataCRCread-onlyoptionalThe value of this object provides the label of the Calibration Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.15Columnoa100bdvalueCalibrationDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.16Columnoa100bdstateflagCalibrationDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.17Columnoa100bdlabelOptInShutdownread-onlyoptionalThe value of this object provides the label of the Optical Input Power Shutdown Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.18Columnoa100bdvalueOptInShutdownread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.19Columnoa100bdstateflagOptInShutdownread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.20Columnoa100bdlabelMainTECTempShutdownread-onlyoptionalThe value of this object provides the label of the Main TEC Temperature Shutdown Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.21Columnoa100bdvalueMainTECTempShutdownread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.22Columnoa100bdstateflagMainTECTempShutdownread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.23Columnoa100bdlabelAuxTECTempShutdownread-onlyoptionalThe value of this object provides the label of the Aux TEC Temperature Shutdown Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.24Columnoa100bdvalueAuxTECTempShutdownread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.25Columnoa100bdstateflagAuxTECTempShutdownread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.26Columnoa100bdlabelPowerFailread-onlyoptionalThe value of this object provides the label of the Power Supply Fail Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.27Columnoa100bdvaluePowerFailread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.28Columnoa100bdstateflagPowerFailread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.29Columnoa100bdlabelKeySwitchread-onlyoptionalThe value of this object provides the label of the Key Switch Setting Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.30Columnoa100bdvalueKeySwitchread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.31Columnoa100bdstateflagKeySwitchread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.32Columnoa100bdlabelMainLaserCurrShutdownread-onlyoptionalThe value of this object provides the label of the Main Laser Current Shutdown Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.33Columnoa100bdvalueMainLaserCurrShutdownread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.34Columnoa100bdstateflagMainLaserCurrShutdownread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.35Columnoa100bdlabelAuxLaserCurrShutdownread-onlyoptionalThe value of this object provides the label of the AuxLaser Current Shutdown Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.36Columnoa100bdvalueAuxLaserCurrShutdownread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.37Columnoa100bdstateflagAuxLaserCurrShutdownread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.38Columnoa100bdlabelMainLaserPowShutdownread-onlyoptionalThe value of this object provides the label of the Main Laser Power Shutdown Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.39Columnoa100bdvalueMainLaserPowShutdownread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.40Columnoa100bdstateflagMainLaserPowShutdownread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.41Columnoa100bdlabelAuxLaserPowShutdownread-onlyoptionalThe value of this object provides the label of the Aux Laser Power Shutdown Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.42Columnoa100bdvalueAuxLaserPowShutdownread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.43Columnoa100bdstateflagAuxLaserPowShutdownread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.44Columnoa100bdlabelADCStatusread-onlyoptionalThe value of this object provides the label of the ADC Operation Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.45Columnoa100bdvalueADCStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.46Columnoa100bdstateflagADCStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.47Columnoa100bdlabelConstGainStatusread-onlyoptionalThe value of this object provides the label of the Constant Gain Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.48Columnoa100bdvalueConstGainStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.49Columnoa100bdstateflagConstGainStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.50Columnoa100bdlabelHardwareErrorStatusread-onlyoptionalThe value of this object provides the label of the Hardware Error Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.51Columnoa100bdvalueHardwareErrorStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.52Columnoa100bdstateflagHardwareErrorStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.4.3.53Columnoa100bdlabelStandbyStatusread-onlyoptionalThe value of this object provides the label of the Standby Status parameter.
1.3.6.1.4.1.1166.6.1.2.17.4.3.54Columnoa100bdvalueStandbyStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.17.4.3.55Columnoa100bdstateflagStandbyStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.17.5Tablegx2OA100BDFactoryTablenot-accessiblemandatoryThis table contains gx2OA100B specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.17.5NodetrapOA100BDOpticalOutPowerAlarmThis trap is issued when the input Optical Output Power parameter goes out of range.
1.3.6.1.4.1.1166.6.1.2.17.5.4Rowgx2OA100BDFactoryEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.17.5.4.1Columngx2OA100BDFactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.17.5.4.2Columnoa100bdbootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from. Boot Control Byte bit definition as follows : bit 0 : boot bit (0=boot…
1.3.6.1.4.1.1166.6.1.2.17.5.4.3Columnoa100bdbootStatusByteread-onlymandatoryThis object indicates the status of the last boot Boot Status Byte bit definitions as follows: bit 0 : bank 0 status (0=bank is OK or not used, 1=bank failed b…
1.3.6.1.4.1.1166.6.1.2.17.5.4.4Columnoa100bdbank0CRCread-onlymandatoryThis object provides the CRC code of bank 0. The value is best displayed in Hex format
1.3.6.1.4.1.1166.6.1.2.17.5.4.5Columnoa100bdbank1CRCread-onlymandatoryThis object provides the CRC code of bank 1. The value is best displayed in Hex format
1.3.6.1.4.1.1166.6.1.2.17.5.4.6Columnoa100bdprgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed programmed EEPROM byte definitions as follows: 0xBB = EEPROM is programmed 0xDB = EEPROM is being resto…
1.3.6.1.4.1.1166.6.1.2.17.5.4.7Columnoa100bdfactoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data. The value is best displayed in Hex format
1.3.6.1.4.1.1166.6.1.2.17.5.4.8Columnoa100bdcalculateCRCread-onlyobsoleteThis object indicates which of the Emnums will have the CRC calculated. Calculate CRC command defintions as follows : 0x00 : recalculate factory data CRC 0x01 …
1.3.6.1.4.1.1166.6.1.2.17.5.4.9Columnoa100bdhourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.17.5.4.10Columnoa100bdflashPrgCntAread-onlymandatoryThis object provides the number of times the flash has been programmed on side A.
1.3.6.1.4.1.1166.6.1.2.17.5.4.11Columnoa100bdflashPrgCntBread-onlymandatoryThis object provides the number of times the flash has been programmed on side B.
1.3.6.1.4.1.1166.6.1.2.17.5.4.12Columnoa100bdfwRev0read-onlymandatoryThis object provides the Revision of the firmware stores in bank 0. This value should be displayed as two ascii characters.
1.3.6.1.4.1.1166.6.1.2.17.5.4.13Columnoa100bdfwRev1read-onlymandatoryThis object provides the Revision of the firmware stores in bank 1. This value should be displayed as two ascii characters.
1.3.6.1.4.1.1166.6.1.2.17.6Tablegx2OA100BDHoldTimeTablenot-accessiblemandatoryThis table contains gx2OA100BD specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.17.6NodetrapOA100BDMainTECTemperatureAlarmThis trap is issued when the OA100B Main TEC Temperature goes out of range.
1.3.6.1.4.1.1166.6.1.2.17.6.5Rowgx2OA100BDHoldTimeEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.17.6.5.1Columngx2OA100BDHoldTimeTableIndexread-onlymandatoryThe value of this object is the index of the data object.
1.3.6.1.4.1.1166.6.1.2.17.6.5.2Columngx2OA100BDHoldTimeSpecIndexread-onlymandatoryThe value of this object identifies the index of the alarm object to be modified.
1.3.6.1.4.1.1166.6.1.2.17.6.5.3Columngx2OA100BDHoldTimeDataread-writemandatoryThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered…
1.3.6.1.4.1.1166.6.1.2.17.7NodetrapOA100BDMainLaserPowerAlarmThis trap is issued when the OA100B Main Laser Power goes out of range.
1.3.6.1.4.1.1166.6.1.2.17.8NodetrapOA100BDAuxTECTemperatureAlarmThis trap is issued when the OA100B Aux TEC Temperature goes out of range.
1.3.6.1.4.1.1166.6.1.2.17.9NodetrapOA100BDAuxLaserPowerAlarmThis trap is issued when the OA100B Aux Laser Power goes out of range.
1.3.6.1.4.1.1166.6.1.2.17.10NodetrapOA100BDFanCurrentAlarmThis trap is issued when the OA100B Module's Fan Currrent parameter goes out of range.
1.3.6.1.4.1.1166.6.1.2.17.11NodetrapOA100BDResetFacDefaultThis trap is issued when the OA100B resets to factory defaults
1.3.6.1.4.1.1166.6.1.2.17.12NodetrapOA100BDStandbyModeThis trap is issued when the OA100B is in Standby Mode.
1.3.6.1.4.1.1166.6.1.2.17.13NodetrapOA100BDOptInShutdownThis trap is issued when the OA100B is in Optical Input Shutdown.
1.3.6.1.4.1.1166.6.1.2.17.14NodetrapOA100BDMainTECTempShutdownThis trap is issued when the OA100B is in Main TEC Temperature Shutdown.
1.3.6.1.4.1.1166.6.1.2.17.15NodetrapOA100BDAuxTECTempShutdownThis trap is issued when the OA100B is in Aux TEC Temperature Shutdown.
1.3.6.1.4.1.1166.6.1.2.17.16NodetrapOA100BDKeySwitchThis trap is issued when the Key Switch disables the OA100B.
1.3.6.1.4.1.1166.6.1.2.17.17NodetrapOA100BDPowerFailThis trap is issued when there is an OA100B Power Supply Failure.
1.3.6.1.4.1.1166.6.1.2.17.18NodetrapOA100BDMainLasCurrShutdownThis trap is issued when the OA100B is in Main Laser Current Shutdown.
1.3.6.1.4.1.1166.6.1.2.17.19NodetrapOA100BDAuxLasCurrShutdownThis trap is issued when the OA100B is in Aux Laser Current Shutdown.
1.3.6.1.4.1.1166.6.1.2.17.20NodetrapOA100BDMainLasPowerShutdownThis trap is issued when the OA100B is in Main Laser Power Shutdown.
1.3.6.1.4.1.1166.6.1.2.17.21NodetrapOA100BDAuxLasPowerShutdownThis trap is issued when the OA100B is in Aux Laser Power Shutdown.
1.3.6.1.4.1.1166.6.1.2.17.22NodetrapOA100BDInvalidModeThis trap is issued when the OA100B is in an invalid mode.
1.3.6.1.4.1.1166.6.1.2.17.23NodetrapOA100BDFlashAlarmThis trap is issued when the OA100B Module's boot or flash programming sequence has detected a Flash error.
1.3.6.1.4.1.1166.6.1.2.17.24NodetrapOA100BDBoot0AlarmThis trap is issued when the OA100B Module's Bank 0 Boot sequence has detected an error.
1.3.6.1.4.1.1166.6.1.2.17.25NodetrapOA100BDBoot1AlarmThis trap is issued when the OA100B Module's Bank 1 Boot sequence has detected an error.
1.3.6.1.4.1.1166.6.1.2.17.26NodetrapOA100BDAlarmDataCRCAlarmThis trap is issued when the OA100B Module detects an error calculating the alarm limit CRC.
1.3.6.1.4.1.1166.6.1.2.17.27NodetrapOA100BDFactoryDataCRCAlarmThis trap is issued when the OA100B Module detects an error calculating the Factory data CRC.
1.3.6.1.4.1.1166.6.1.2.17.28NodetrapOA100BDCalDataCRCAlarmThis trap is issued when the OA100B Module detects an error calculating the Calibration data CRC.
1.3.6.1.4.1.1166.6.1.2.17.29NodetrapOA100BDFacCalFloatAlarmThis trap is issued when the OA100B Module detects factory calibration float data alarm.
1.3.6.1.4.1.1166.6.1.2.17.30NodetrapOA100BDOptInThreshAlarmThis trap is issued when the OA100B Module Optical Input drops below the user set threshold.
1.3.6.1.4.1.1166.6.1.2.17.31NodetrapOA100BDGainErrorAlarmThis trap is issued when the OA100B Module can not produce the desired user set gain in Constant Gain Set Mode.
1.3.6.1.4.1.1166.6.1.2.17.32NodetrapOA100BDHardwareErrorAlarmThis trap is issued when any of the OA100BD Module's TEC,Laser, +12V, or +3.7V current parameters go out of range.