MIB Viewer

PANDATEL-FME-MODEM-MIB

25 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.760.1.1.2.1.10.601Nodefme
1.3.6.1.4.1.760.1.1.2.1.10.601.1TablefmeModemTablenot-accessiblemandatoryThis table contains information about all FME units within all stacks.
1.3.6.1.4.1.760.1.1.2.1.10.601.1.1RowfmeTableEntrynot-accessiblemandatoryThe index of the table.
1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.1ColumnmdmRackread-onlymandatoryThe index of the stack the unit belongs to. The stack corresponds to a rack, the FME units correspond to rack mount cards installed in a rack.
1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.2ColumnmdmModemread-onlymandatoryThis entry displays the index of the FME unit. It corresponds with its position in the stack.
1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.3ColumnmdmPositionread-onlymandatoryThis entry displays the location of the corresponding unit: 'local' or 'remote'. The unit which belongs to a managed stack is 'local', the counterpart is 'remo…
1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.5ColumnmdmModemNameread-onlymandatoryThe verbal name of this unit.
1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.12ColumnmdmActiveLinkread-onlymandatoryThis entry displays the line port that is receiving data.
1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.116ColumnmdmAlarmConditionPort7read-writemandatoryThe alarm trigger mode at port 7: 'disable', i.e. no alarm is triggered, 'no-link-signal', i.e. an alarm is triggered if the link is down, 'laser-fail', i.e. a…
1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.117ColumnmdmAlarmConditionPort8read-writemandatoryThe alarm trigger mode at port 8: 'disable', i.e. no alarm is triggered, 'no-link-signal', i.e. an alarm is triggered if the link is down, 'laser-fail', i.e. a…
1.3.6.1.4.1.760.1.1.2.1.10.601.2TablefmePortTablenot-accessiblemandatoryThis table contains information about all I/F ports of the FME units within all stacks.
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1RowfmePortEntrynot-accessiblemandatoryThe index of the table.
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.1ColumnportRackread-onlymandatoryThe index of the stack the port belongs to.
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.2ColumnportModemread-onlymandatoryThe index of the FME unit the port belongs to.
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.3ColumnportPositionread-onlymandatoryThis entry displays the location of the corresponding port: 'local' or 'remote'. The port which belongs to a managed stack is 'local', the counterpart is 'remo…
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.4ColumnportPortread-onlymandatoryThe index of the port.
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.6ColumnportInterfaceEmulationModeread-onlymandatoryInterface mode of the port: 'dte', 'dce', 'te', or 'nt'.
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.7ColumnmdmModemPropertyread-onlymandatoryThe speed class of the port: 'e1' or 't1'.
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.23ColumnportClockSystemread-writemandatoryThe clock system at the interface port: 'single' or 'dual'. The available values depend on the interface type.
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.24ColumnportClockSourceread-writemandatoryThe clock source at the interface port: 'internal', 'remote', or 'external'.
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.25ColumnportDataRateread-writemandatoryThe data rate at the interface port in bits per seconds. The data rate at the remote counterpart changes simultaneously.
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.60ColumnportLocalCarrierDetectread-writemandatoryThe data carrier detect mode at the interface: if set to 'fo-link-and-remote-handshake' the DCD signal (resp. I for X.21, etc.) follows link status and remote …
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.67ColumnportTDPhaseLockingread-writemandatoryThis entry defines the data phase locking for I/F data: 'positive-clock-slope' or 'negative-clock-slope'. For units with G.703 onboard the value 'positive-cloc…
1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.68ColumnportLineBuiltOutread-writemandatoryThe G.703 transmission mode of the unit. Valid for units with G.703 onboard only.
1.3.6.1.4.1.760.1.1.2.1.10.10000.2.601Nodefme-modem