PANDATEL-FME-MODEM-MIB
25 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.760.1.1.2.1.10.601 | Nodefme | |||
| 1.3.6.1.4.1.760.1.1.2.1.10.601.1 | TablefmeModemTable | not-accessible | mandatory | This table contains information about all FME units within all stacks. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.1.1 | RowfmeTableEntry | not-accessible | mandatory | The index of the table. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.1 | ColumnmdmRack | read-only | mandatory | The index of the stack the unit belongs to. The stack corresponds to a rack, the FME units correspond to rack mount cards installed in a rack. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.2 | ColumnmdmModem | read-only | mandatory | This entry displays the index of the FME unit. It corresponds with its position in the stack. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.3 | ColumnmdmPosition | read-only | mandatory | This entry displays the location of the corresponding unit: 'local' or 'remote'. The unit which belongs to a managed stack is 'local', the counterpart is 'remo… |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.5 | ColumnmdmModemName | read-only | mandatory | The verbal name of this unit. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.12 | ColumnmdmActiveLink | read-only | mandatory | This entry displays the line port that is receiving data. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.116 | ColumnmdmAlarmConditionPort7 | read-write | mandatory | The alarm trigger mode at port 7: 'disable', i.e. no alarm is triggered, 'no-link-signal', i.e. an alarm is triggered if the link is down, 'laser-fail', i.e. a… |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.1.1.117 | ColumnmdmAlarmConditionPort8 | read-write | mandatory | The alarm trigger mode at port 8: 'disable', i.e. no alarm is triggered, 'no-link-signal', i.e. an alarm is triggered if the link is down, 'laser-fail', i.e. a… |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2 | TablefmePortTable | not-accessible | mandatory | This table contains information about all I/F ports of the FME units within all stacks. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1 | RowfmePortEntry | not-accessible | mandatory | The index of the table. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.1 | ColumnportRack | read-only | mandatory | The index of the stack the port belongs to. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.2 | ColumnportModem | read-only | mandatory | The index of the FME unit the port belongs to. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.3 | ColumnportPosition | read-only | mandatory | This entry displays the location of the corresponding port: 'local' or 'remote'. The port which belongs to a managed stack is 'local', the counterpart is 'remo… |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.4 | ColumnportPort | read-only | mandatory | The index of the port. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.6 | ColumnportInterfaceEmulationMode | read-only | mandatory | Interface mode of the port: 'dte', 'dce', 'te', or 'nt'. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.7 | ColumnmdmModemProperty | read-only | mandatory | The speed class of the port: 'e1' or 't1'. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.23 | ColumnportClockSystem | read-write | mandatory | The clock system at the interface port: 'single' or 'dual'. The available values depend on the interface type. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.24 | ColumnportClockSource | read-write | mandatory | The clock source at the interface port: 'internal', 'remote', or 'external'. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.25 | ColumnportDataRate | read-write | mandatory | The data rate at the interface port in bits per seconds. The data rate at the remote counterpart changes simultaneously. |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.60 | ColumnportLocalCarrierDetect | read-write | mandatory | The data carrier detect mode at the interface: if set to 'fo-link-and-remote-handshake' the DCD signal (resp. I for X.21, etc.) follows link status and remote … |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.67 | ColumnportTDPhaseLocking | read-write | mandatory | This entry defines the data phase locking for I/F data: 'positive-clock-slope' or 'negative-clock-slope'. For units with G.703 onboard the value 'positive-cloc… |
| 1.3.6.1.4.1.760.1.1.2.1.10.601.2.1.68 | ColumnportLineBuiltOut | read-write | mandatory | The G.703 transmission mode of the unit. Valid for units with G.703 onboard only. |
| 1.3.6.1.4.1.760.1.1.2.1.10.10000.2.601 | Nodefme-modem |