PANDATEL-FOBUS-MODEM-MIB
16 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.760.1.1.2.1.10.501 | Nodefobus | |||
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1 | TablefobusModemTable | not-accessible | mandatory | This table contains information about all FOBUS units in all racks. |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1 | RowfobusTableEntry | not-accessible | mandatory | The index of the table. |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.1 | ColumnmdmRack | read-only | mandatory | The index of the rack where the unit is installed. |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.2 | ColumnmdmModem | read-only | mandatory | This entry displays the slot number where the corresponding unit is installed in the rack. |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.3 | ColumnmdmPosition | read-only | mandatory | This entry displays the location of the corresponding unit: 'local' or 'remote'. The unit which is plugged into a managed rack is 'local', the counterpart is '… |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.5 | ColumnmdmModemName | read-only | mandatory | The verbal name of this unit. |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.11 | ColumnmdmBackupStatus | read-only | mandatory | The backup status of the unit. The available values depend on the generation of the unit. |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.12 | ColumnmdmActiveLink | read-only | mandatory | This entry displays the line port used for data transmission. |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.66 | ColumnmdmOperationMode | read-write | mandatory | This entry defines if data is transmitted via port 2 or port 3: 'forced-port2', 'forced-port3', 'automatic'. |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.110 | ColumnmdmAlarmConditionPort1 | read-write | mandatory | The alarm trigger mode at port 1: 'disable', i.e. no alarm is triggered, or 'link-signal', i.e. an alarm is triggered if the link is down. |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.111 | ColumnmdmAlarmConditionPort2 | read-write | mandatory | The alarm trigger mode at port 2: 'disable', i.e. no alarm is triggered, 'no-link-signal', i.e. an alarm is triggered if the link is down, 'laser-fail', i.e. a… |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.112 | ColumnmdmAlarmConditionPort3 | read-write | mandatory | The alarm trigger mode at port 3: 'disable', i.e. no alarm is triggered, 'no-link-signal', i.e. an alarm is triggered if the link is down, 'laser-fail', i.e. a… |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.121 | ColumnmdmTXLaserStatusPort2 | read-only | mandatory | This entry indicates if the laser diode at port 2 is transmitting data ('enable') or not ('disable'). |
| 1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.122 | ColumnmdmTXLaserStatusPort3 | read-only | mandatory | This entry indicates if the laser diode at port 3 is transmitting data ('enable') or not ('disable'). |
| 1.3.6.1.4.1.760.1.1.2.1.10.10000.2.501 | Nodefobus-modem |