PANDATEL-GMSF-MODEM-MIB
24 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.760.1.1.2.1.10.205 | Nodegmsf | |||
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1 | TablegmsfModemTable | not-accessible | mandatory | This table contains information about all GM-F converters in all racks. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1 | RowgmsfTableEntry | not-accessible | mandatory | The index of the table. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.1 | ColumnmdmRack | read-only | mandatory | The index of the rack where the converter is installed. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.2 | ColumnmdmModem | read-only | mandatory | This entry displays the slot number where the corresponding converter is installed in the rack. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.3 | ColumnmdmPosition | read-only | mandatory | This entry displays the location of the corresponding converter: 'local' or 'remote'. The converter which is plugged into a managed rack is 'local', the counte… |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.5 | ColumnmdmModemName | read-only | mandatory | The verbal name of this converter. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.6 | ColumnmdmInterfaceEmulationMode | read-only | mandatory | Interface mode of the unit: 'dte', 'dce', 'te' or 'nt'. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.7 | ColumnmdmModemProperty | read-only | mandatory | This entry displays the speed class of the GM-F: 'e1' or 't1'. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.10 | ColumnmdmHDSLUnit | read-write | mandatory | HDSL unit type: Line Termination Unit (LTU) or Network Termination Unit (LTU) |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.23 | ColumnmdmClockSystem | read-write | mandatory | The clock system of the link: 'dual' or 'single'. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.24 | ColumnmdmClockSource | read-write | mandatory | The clock source of the link: 'internal', 'external', or 'remote'. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.25 | ColumnmdmDataRate | read-write | mandatory | The data rate at the interface in bits per seconds. The data rate at the remote counterpart changes simultaneously. A data rate of 2.048 Mbps (E1) automaticall… |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.26 | ColumnmdmStartTimeslot | read-write | mandatory | This entry determines the start time slot for framing. Start time slot and data rate must match. A start time slot which is too high will be ignored. The remot… |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.27 | ColumnmdmTimeslotSize | read-write | mandatory | This entry determines the size of the time slots: 'nx64k' or 'nx56k'. 'nx56k' is valid for T1 units only. The remote unit's configuration changes simultaneousl… |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.40 | ColumnmdmTimeslot16 | read-write | mandatory | This entry enables or disables time slot 16. If it is disabled, it will not be used for data transmission but for framing. Valid for E1 units only. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.41 | ColumnmdmCRC4Generation | read-write | mandatory | This entry enables or disables the generation of a CRC4 check sum. Valid for E1 units only. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.50 | ColumnmdmFramingMode | read-write | mandatory | The T1 framing mode: 'd4' or 'esf'. The remote unit's configuration changes simultaneously. Valid for T1 units only. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.63 | ColumnmdmScrambler | read-write | mandatory | This entry enables or disables scrambling. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.64 | ColumnmdmRemoteAccessMode | read-write | mandatory | The remote access mode: 'disable', 'via-next-free-timeslot', 'via-timeslot-0-Sa4-bit', or 'via-hdsl-channel'. The value 'via-next-free-timeslot' means that one… |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.100 | ColumnmdmCRC6Test | read-write | mandatory | This entry enables the execution of a CRC6 test. Write requests with values other than 'start' or 'stop' will be rejected. Valid for T1 units only. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.101 | ColumnmdmCRC6Status | read-only | mandatory | This entry indicates the status of the CRC6 test. Valid for T1 units only. |
| 1.3.6.1.4.1.760.1.1.2.1.10.205.1.1.102 | ColumnmdmCRC6Error | read-only | mandatory | This entry indicates the number of errors detected during the last 60 seconds. |
| 1.3.6.1.4.1.760.1.1.2.1.10.10000.2.205 | Nodegmsf-modem |