MIB Viewer

PBC-KODIAK-M-G10-MIB

60 objects
MIB Module for the Kodiak M-G10 CMTS.
OIDNameAccessStatusDescription
1.3.6.1.4.1.5987.1.1.3IdentitypbcKodiakMG10MibMIB Module for the Kodiak M-G10 CMTS.
1.3.6.1.4.1.5987.3.1NodepbcKodiakMG10Cmts
1.3.6.1.4.1.5987.3.1.1NodepbcG10SystemEnvMon
1.3.6.1.4.1.5987.3.1.1.1NodesytemEnvMonObjects
1.3.6.1.4.1.5987.3.1.1.1.1NodesystemEnvMonPowerSupply
1.3.6.1.4.1.5987.3.1.1.1.1.1ScalarsystemEnvMonPowerSupplyEntityIndexread-writecurrententPhysicalIndex of this card's entry in the Entity MIB's (RFC2737) entPhysicalTable or '0', if none.
1.3.6.1.4.1.5987.3.1.1.1.1.2ScalarsystemEnvMonPowerSupplyStatusread-writecurrentDescription.
1.3.6.1.4.1.5987.3.1.1.1.3NodesystemEnvMonTemperature
1.3.6.1.4.1.5987.3.1.1.1.3.1ScalarsystemEnvMonAmbientTemperatureHighThresholdread-writecurrentIf the ambient temperature exceeds this value, a warning notification will be generated. The user may use this feature to be alerted to problems with the HVAC …
1.3.6.1.4.1.5987.3.1.1.1.3.2ScalarsystemEnvMonAmbientTemperatureLowThresholdread-writecurrentIf the ambient temperature falls below this value, a warning notification will be generated. The user may use this feature to be alerted to problems with the H…
1.3.6.1.4.1.5987.3.1.1.1.3.3ScalarsystemEnvMonAmbientTermperatureNumEntriesread-onlycurrentNumber of entries in the temperature monitoring status table.
1.3.6.1.4.1.5987.3.1.1.1.3.4TablesystemEnvMonAmbientTemperatureTablenot-accessiblecurrentTable of temperature status maintained by the system/chassis environment monitor.
1.3.6.1.4.1.5987.3.1.1.1.3.4.1RowsystemEnvMonAmbientTemperatureEntrynot-accessiblecurrentAn entry in the temperature status table representing the status of ambient temperature monitoring on one module (card). The index is the same as that used in …
1.3.6.1.4.1.5987.3.1.1.1.3.4.1.1ColumnsystemEnvMonAmbientTemperatureread-onlycurrentCurrent temperature at the monitoring point for this module (card).
1.3.6.1.4.1.5987.3.1.1.1.5ScalarsystemEnvMonFanTrayStatusNumEntriesread-onlycurrentNumber of entries in the fan status monitoring table.
1.3.6.1.4.1.5987.3.1.1.1.6TablesystemEnvMonFanTrayStatusTablenot-accessiblecurrentTable of fan status maintained by the system environment monitor.
1.3.6.1.4.1.5987.3.1.1.1.6.1RowsystemEnvMonFanTrayStatusEntrynot-accessiblecurrentAn entry in the temperature status table representing the status of one monitoring point.
1.3.6.1.4.1.5987.3.1.1.1.6.1.1ColumnsystemEnvMonFanTrayStatusIndexread-onlycurrentChassis-assigned ndex number of this fan tray.
1.3.6.1.4.1.5987.3.1.1.1.6.1.2ColumnsystemEnvMonFanTrayStatusEntityIndexread-onlycurrententPhysicalIndex of this fan tray's entry in the Entity MIB's (RFC2737) entPhysicalTable or '0', if none.
1.3.6.1.4.1.5987.3.1.1.1.7ScalarsystemEnvMonFanStatusNumEntriesread-onlycurrentNumber of fan entries in the fan status table.
1.3.6.1.4.1.5987.3.1.1.1.8TablesystemEnvMonFanStatusTablenot-accessiblecurrentTable with individual fan speeds for the fans in each tray.
1.3.6.1.4.1.5987.3.1.1.1.8.1RowsystemEnvMonFanStatusEntrynot-accessiblecurrentFan speed and thresholds for one fan.
1.3.6.1.4.1.5987.3.1.1.1.8.1.1ColumnsystemEnvMonFanStatusIndexread-onlycurrentDescription.
1.3.6.1.4.1.5987.3.1.1.1.8.1.2ColumnsystemEnvMonFanStatusSpeedread-onlycurrentCurrent speed of the fan.
1.3.6.1.4.1.5987.3.1.2NodepbcG10SystemConformance
1.3.6.1.4.1.5987.3.1.2.1NodepbcG10SystemGroups
1.3.6.1.4.1.5987.3.1.2.1.1GrouppbcSystemEnvMonGroupcurrentObjects associated with system environment monitoring.
1.3.6.1.4.1.5987.3.1.2.1.2GrouppbcG10RedundancyGroupcurrentObjects associated with DM, NIC and CCM Module Redundancy.
1.3.6.1.4.1.5987.3.1.2.3NodepbcG10SystemCompliance
1.3.6.1.4.1.5987.3.1.2.3.1CompliancepbcG10SystemBasicCompliancecurrentGroup support required for basic G10 level compliance.
1.3.6.1.4.1.5987.3.1.2.3.2CompliancepbcG10RedundancyCompliancecurrentGroup support required for G10 Redundancy compliance.
1.3.6.1.4.1.5987.3.1.3NodepbcG10DMRedundancy
1.3.6.1.4.1.5987.3.1.3.1TablepbcG10CmtsDMRGroupTablenot-accessiblecurrentTable Containing the status of various DOCSIS Module Redunduncy Groups. If ths are no DM Reundandancy Groups present on the G10 CMTS, this table is empty.
1.3.6.1.4.1.5987.3.1.3.1.1RowpbcG10CmtsDMRGroupEntrynot-accessiblecurrentAn entry describing the status of various DOCSIS Module Redundancy Groups.
1.3.6.1.4.1.5987.3.1.3.1.1.1ColumnpbcG10CmtsDMRGroupIndexaccessible-for-notifycurrentAn Unique identifier that identifies a DOCSIS Module Redundancy Group. Its value is the same as the slot number that contains the Standby DOCSIS Module within …
1.3.6.1.4.1.5987.3.1.3.1.1.2ColumnpbcG10CmtsDMRGroupSlotNbraccessible-for-notifycurrentThe slot number of the corresponding DOCSIS Module.
1.3.6.1.4.1.5987.3.1.3.1.1.3ColumnpbcG10CmtsDMRGroupDmCardIndexread-onlycurrentThe index in the pbcCardTable for the corresponding DOCSIS Module. If the DOCSIS Module is not present in the system, this value is reported as 0.
1.3.6.1.4.1.5987.3.1.3.1.1.4ColumnpbcG10CmtsDMRGroupImCardIndexread-onlycurrentThe index in the pbcCardTable for the corresponding Real I/O Module. The corresponding Rear I/O Module MUST always be present in the system, or else this entry…
1.3.6.1.4.1.5987.3.1.3.1.1.5ColumnpbcG10CmtsDMRGroupRoleread-onlycurrentThe role of this DOCSIS Module in the Redundancy Group. The active (1) role corresponds to a DOCSIS Module where the external R/F connections terminate and is …
1.3.6.1.4.1.5987.3.1.3.1.1.6ColumnpbcG10CmtsDMRGroupStatusread-onlycurrentDefines the operational status of the corresponding DOCSIS Module card. The notPresent (1) status implies that the DOCSIS Module has been removed from the syst…
1.3.6.1.4.1.5987.3.1.3.1.1.7ColumnpbcG10CmtsDMRGroupAliasread-onlycurrentFor a module in the standby role, this object has a value of 0 if it is not covering any active modules, else it identifies the slot number of the DOCSIS Modul…
1.3.6.1.4.1.5987.3.1.3.1.1.8ColumnpbcG10CmtsDMRGroupActionread-onlycurrentThis object allows the operator to take certain actions on the corresponding DOCSIS Module. Action none (1) has no effect on the DOCSIS Module. The exclude (2)…
1.3.6.1.4.1.5987.3.1.3.1.1.9ColumnpbcG10CmtsDMRGroupSwitchInread-writecurrentWhen read, this object specifies the time in seconds relative to the current time when a switchover is scheduled for this module, or 0 if no switchover has bee…
1.3.6.1.4.1.5987.3.1.3.1.1.10ColumnpbcG10CmtsDMRGroupSwitchAtread-writecurrentWhen read, this object specifies the time when a switchover is scheduled for this module, or an NULL (Hex String 00 00 00 00 00 00 00 00) value if no switchove…
1.3.6.1.4.1.5987.3.1.3.2ScalarpbcG10CmtsDMRGroupFreezeread-writecurrentWriting freeze (1) would disallow all the Redundancy configuration changes. To be able to make configuration changes, this value has to be nofreeze (2).
1.3.6.1.4.1.5987.3.1.4NodepbcG10CmtsCCMRedundancy
1.3.6.1.4.1.5987.3.1.4.1NodepbcG10CmtsCCMRedundancyObject
1.3.6.1.4.1.5987.3.1.4.1.1ScalarpbcG10CmtsCCMPrimarySlotread-onlycurrentIdentifies the slot number of the CCM Module that is currently in the primary role.
1.3.6.1.4.1.5987.3.1.4.1.2ScalarpbcG10CmtsCCMActionread-writecurrentThis object allows the operator to take certain actions on the CCM Module. Action none (1) has no effect on the CCM Module. The switchIn (2) action schedules t…
1.3.6.1.4.1.5987.3.1.4.1.3ScalarpbcG10CmtsCCMSwitchInread-writecurrentWhen read, this object specifies the time in seconds relative to the current time when a switchover is scheduled for the currently active CCM module, or 0 if n…
1.3.6.1.4.1.5987.3.1.4.1.4ScalarpbcG10CmtsCCMSwitchAtread-writecurrentWhen read, this object specifies the time when a switchover is scheduled for the currently active CCM module, or an NULL (Hex String 00 00 00 00 00 00 00 00) v…
1.3.6.1.4.1.5987.3.1.5NodepbcG10CmtsNICRedundancy
1.3.6.1.4.1.5987.3.1.5.1NodepbcG10CmtsNICRedundancyObject
1.3.6.1.4.1.5987.3.1.5.1.1ScalarpbcG10CmtsNICRedundancyEnableread-writecurrentEnable/Disable NIC Redundancy for the whole system.
1.3.6.1.4.1.5987.3.1.5.1.2TablepbcG10CmtsNicDmConnectivityTablenot-accessiblecurrentTable containing information about connectivity between DOCSIS and NIC modules. For every DOCSIS Module in the system there is two entries in this table (One f…
1.3.6.1.4.1.5987.3.1.5.1.2.1RowpbcG10CmtsNicDmConnectivityEntrynot-accessiblecurrentAn entry describing the status of connectivity between DOCSIS Modules and NIC modules.
1.3.6.1.4.1.5987.3.1.5.1.2.1.1ColumnpbcG10CmtsNicDmConnectivityDmIndexnot-accessiblecurrentA unique identifier that identifies a DOCSIS Module.
1.3.6.1.4.1.5987.3.1.5.1.2.1.2ColumnpbcG10CmtsNicDmConnectivityCableInterfaceIndexnot-accessiblecurrentCable Connectivity mode index to differentiate between Odd and Even cable interfaces in the DOCSIS Module. 1. oddCableInterfaces (1) meaning all odd numbered c…
1.3.6.1.4.1.5987.3.1.5.1.2.1.3ColumnpbcG10CmtsNicDmConnectivityDmCardSlotNumberread-writecurrentSlot Number where the DOCSIS Modules resides in the chassis.
1.3.6.1.4.1.5987.3.1.5.1.2.1.4ColumnpbcG10CmtsNicDmConnectivityConnectToread-writecurrentThe DOCSIS Module connects to the NIC module in slot 5 if pbcG10CmtsNicDmConnectivityConnectTo is nic5 (1), or NIC module in slot 9 if pbcG10CmtsNicDmConnectiv…