PEA-BB-SELT
40 objects
In this module are defined the control entries for input and output data for different types of broadband line tests.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 0.0 | ScalarbbSeltTestType | read-write | current | |
| 0.0 | NodenoTest | |||
| 1.3.6.1.4.1.193.72.602.10 | IdentitybbSelt | In this module are defined the control entries for input and output data for different types of broadband line tests. | ||
| 1.3.6.1.4.1.193.72.602.10.5 | NodebbSeltTestGroup | |||
| 1.3.6.1.4.1.193.72.602.10.5.1 | TablebbSeltTestTable | not-accessible | current | This table contains one entry per line. It defines objects which allow a network manager to instruct an agent to test a line for various faults. Tests for a li… |
| 1.3.6.1.4.1.193.72.602.10.5.1.1 | RowbbSeltTestEntry | not-accessible | current | An entry containing objects for invoking tests on a line. |
| 1.3.6.1.4.1.193.72.602.10.5.1.1.1 | ColumnbbSeltTestId | read-write | current | This object identifies the current invocation of the line's test. |
| 1.3.6.1.4.1.193.72.602.10.5.1.1.2 | ColumnbbSeltTestStatus | read-write | current | This object indicates whether or not some manager currently has the necessary 'ownership' required to invoke a test on this line. A write to this object is onl… |
| 1.3.6.1.4.1.193.72.602.10.5.1.1.4 | ColumnbbSeltTestResult | read-only | current | This object contains the result of the most recently requested test, or the value none(1) if no tests have been requested since the last reset. Note that this … |
| 1.3.6.1.4.1.193.72.602.10.5.1.1.5 | ColumnbbSeltTestResultDetails | read-only | current | This object contains a comment-string, which gives more specific information about the test result. For instance, after a failed test a comment will describe t… |
| 1.3.6.1.4.1.193.72.602.10.5.1.1.6 | ColumnbbSeltTestOwner | read-write | current | The entity, which currently has the 'ownership' required to invoke a test on this line. For instance, it could be the IP address of the manager-station or the … |
| 1.3.6.1.4.1.193.72.602.10.5.1.1.7 | ColumnbbSeltTestAbort | read-write | current | This object indicates whether or not the owner manager requires the 'abort' of the sub-tests current set on the line where the test is running. A writing to th… |
| 1.3.6.1.4.1.193.72.602.10.10 | NodebbSeltEchoGroup | |||
| 1.3.6.1.4.1.193.72.602.10.10.1 | TablebbSeltEchoInputTable | not-accessible | current | This table provides the input parameters for the Extended NB SELT test |
| 1.3.6.1.4.1.193.72.602.10.10.1.1 | RowbbSeltEchoInputEntry | not-accessible | current | An entry contains input parameters for the SELT test for the subscriber line identified by ifIndex. |
| 1.3.6.1.4.1.193.72.602.10.10.1.1.1 | ColumnbbSeltEchoMeasLength | read-write | current | This parameter controls the duration of the echo measurement. The measurment is performed over a period equal to 2^measurmentLength DMT signals (without the cy… |
| 1.3.6.1.4.1.193.72.602.10.10.2 | TablebbSeltEchoOutputTable | not-accessible | current | This table provides the output parameters for the Extended NB SELT test |
| 1.3.6.1.4.1.193.72.602.10.10.2.1 | RowbbSeltEchoOutputEntry | not-accessible | current | An entry contains Output parameters for the SELT test for the subscriber line identified by ifIndex. |
| 1.3.6.1.4.1.193.72.602.10.10.2.1.1 | ColumnbbSeltEchoVec0 | read-only | current | Part 0 (0-63) of BB-SELT echo vector. |
| 1.3.6.1.4.1.193.72.602.10.10.2.1.2 | ColumnbbSeltEchoVec1 | read-only | current | Part 1 (64-127) of BB-SELT echo vector. |
| 1.3.6.1.4.1.193.72.602.10.10.2.1.3 | ColumnbbSeltEchoVec2 | read-only | current | Part 2 (128..191) of BB-SELT echo vector. |
| 1.3.6.1.4.1.193.72.602.10.10.2.1.4 | ColumnbbSeltEchoVec3 | read-only | current | Part 3 (192..255) of BB-SELT echo vector. |
| 1.3.6.1.4.1.193.72.602.10.10.2.1.5 | ColumnbbSeltEchoVec4 | read-only | current | Part 4 (256-319) of BB-SELT echo vector. |
| 1.3.6.1.4.1.193.72.602.10.10.2.1.6 | ColumnbbSeltEchoVec5 | read-only | current | Part 5 (320-383) of BB-SELT echo vector. |
| 1.3.6.1.4.1.193.72.602.10.10.2.1.7 | ColumnbbSeltEchoVec6 | read-only | current | Part 6 (384-447) of BB-SELT echo vector. |
| 1.3.6.1.4.1.193.72.602.10.10.2.1.8 | ColumnbbSeltEchoVec7 | read-only | current | Part 7 (448-512) of BB-SELT echo vector. |
| 1.3.6.1.4.1.193.72.602.10.10.2.1.9 | ColumnbbSeltAgcValue | read-only | current | Receiver gain used during last BB-SELT echo measurement. |
| 1.3.6.1.4.1.193.72.602.10.15 | NodebbSeltNoiseGroup | |||
| 1.3.6.1.4.1.193.72.602.10.15.1 | TablebbSeltNoiseInputTable | not-accessible | current | This table provides the input parameters for the BB SELT Noise test |
| 1.3.6.1.4.1.193.72.602.10.15.1.1 | RowbbSeltNoiseInputEntry | not-accessible | current | An entry contains input parameters for the SELT for the subscriber line identified by ifIndex. |
| 1.3.6.1.4.1.193.72.602.10.15.1.1.1 | ColumnbbSeltNoiseMeasLength | read-write | current | This parameter controls the duration of the noise measurement. The measurment is performed over a period equal to 2^measurmentLength DMT signals (without the c… |
| 1.3.6.1.4.1.193.72.602.10.15.2 | TablebbSeltNoiseOutputTable | not-accessible | current | This table provides the output parameters for the BB SELT Noise test |
| 1.3.6.1.4.1.193.72.602.10.15.2.1 | RowbbSeltNoiseOutputEntry | not-accessible | current | An entry contains output parameters for the SELT for the subscriber line identified by ifIndex. |
| 1.3.6.1.4.1.193.72.602.10.15.2.1.1 | ColumnbbSeltPeakNoise | read-only | current | Peak PSD from tone [0-63] observed over the testDuration. Unit is 1/256 dBm/tonebin and is referred to 100 ohm line. |
| 1.3.6.1.4.1.193.72.602.10.15.2.1.2 | ColumnbbSeltTotalNoise | read-only | current | Total PSD from tone [0-63] observed over the testDuration. Unit is 1/256 dBm/tonebin and is referred to 100 ohm line. |
| 1.3.6.1.4.1.193.72.602.10.15.2.1.3 | ColumnbbSeltSignalNoise | read-only | current | Signal PSD from tone [0-63] observed over the testDuration. Unit is 1/256 dBm/tonebin and is referred to 100 ohm line. |
| 1.3.6.1.4.1.193.72.602.10.100 | NodebbSeltNotificationGroup | |||
| 1.3.6.1.4.1.193.72.602.10.100.0 | NodebbSeltNotificationTypes | |||
| 1.3.6.1.4.1.193.72.602.10.100.0.1 | NotificationbbSeltCompletion | current | When a test is ready an ifTestCompletion trap is sent to the Manager / Trap Receiver. Parameters: 1: Managed object class MSAN Port 2: Managed object ID MAC + … | |
| 1.3.6.1.4.1.193.72.602.10.100.1 | NodebbSeltNotificationParameters |