PEA-TEST-IPDSLAM
186 objects
In this module are defined the control entries for input and output data for SELT (loop qualification) and NOISE tests.
Imported Objects
| DIESEL-SMI | peaIpDslam |
| PEA-BRIDGE-IPDSLAM | lineIndex pvcIndex |
| PEA-IF-IPDSLAM | adslIfTestError adslIfTestResult adslIfTestType |
| PEM-STANDARD | 733 header for the traps managedObjectClass eventTime eventTypePem managedObjectInstance perceivedSeverity probableCause sequenceNumber |
| SNMPv2-CONF | NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.193.72.300.20 | IdentitypeaTestIpDslam | In this module are defined the control entries for input and output data for SELT (loop qualification) and NOISE tests. | ||
| 1.3.6.1.4.1.193.72.300.20.1 | NodepeaTestIpDslamObjects | |||
| 1.3.6.1.4.1.193.72.300.20.1.1 | TableseltTestInputTable | not-accessible | current | This table provides the input parameters for the SELT test. |
| 1.3.6.1.4.1.193.72.300.20.1.1.1 | RowseltTestInputEntry | not-accessible | current | An entry contains input parameters for the SELT test for the subscriber line identified by lineIndex. |
| 1.3.6.1.4.1.193.72.300.20.1.1.1.1 | ColumnseltNoiseNeAct | read-write | current | Value that indicates if Near-end noise should be measured or pre-selected. If the noise should be measured this should be Activated(1). If the noise should be … |
| 1.3.6.1.4.1.193.72.300.20.1.1.1.2 | ColumnseltNoiseFeAct | read-write | current | Value that indicates if Far-end noise should be measured or pre-selected. If the noise should be measured this should be Activated(1). If the noise should be p… |
| 1.3.6.1.4.1.193.72.300.20.1.1.1.3 | ColumnseltAdvOutputTableAct | read-write | current | Switch that activates presentation of tone information or deactivates it. |
| 1.3.6.1.4.1.193.72.300.20.1.1.1.8 | ColumnseltToneProfile | read-write | current | Tone profile for different system configurations. The unused values for this parameter are reserved for comming standards or future proprietary techniques. |
| 1.3.6.1.4.1.193.72.300.20.1.1.1.9 | ColumnseltVop | read-write | current | Velocity of propagation is the speed at which an electric signal passes through a cable. |
| 1.3.6.1.4.1.193.72.300.20.1.1.1.10 | ColumnseltUsToneMask | read-write | current | Upstream active tones assumed in capacity estimation. Using single bits in integer set specific tones on /off. Total number of tones is 256. |
| 1.3.6.1.4.1.193.72.300.20.1.1.1.11 | ColumnseltDsToneMask | read-write | current | Downstream active tones assumed in capacity estimation. Using single bits in integer set specific tones on /off. Total number of tones is 512. |
| 1.3.6.1.4.1.193.72.300.20.1.1.1.12 | ColumnseltUsTransmitLevel | read-write | current | Upstream transmit level. |
| 1.3.6.1.4.1.193.72.300.20.1.1.1.13 | ColumnseltDsTransmitLevel | read-write | current | Downstream transmit level. |
| 1.3.6.1.4.1.193.72.300.20.1.1.1.14 | ColumnseltExtSplitterType | read-write | current | External splitter filter type. This parameter is used to inform the SELT software about any installed external splitter filter. The SELT performance is affecte… |
| 1.3.6.1.4.1.193.72.300.20.1.3 | TableseltTestBasicOutputTable | not-accessible | current | This table provides the basic output parameters for the SELT test. |
| 1.3.6.1.4.1.193.72.300.20.1.3.1 | RowseltTestBasicOutputEntry | not-accessible | current | An entry contains the basic output parameters for the SELT test for the subscriber line identified by lineIndex. |
| 1.3.6.1.4.1.193.72.300.20.1.3.1.1 | ColumnseltLength | read-only | current | Loop length to termination. |
| 1.3.6.1.4.1.193.72.300.20.1.3.1.2 | ColumnseltSingleAttVal | read-only | current | Attenuation at 300kHz. |
| 1.3.6.1.4.1.193.72.300.20.1.3.1.3 | ColumnseltAdslDeployment | read-only | current | Parameter indicating the possibility for ADSL deployment. A value of Possible(0) indicates that the tested loop is possible for ADSL Deployment, Uncertain(1) i… |
| 1.3.6.1.4.1.193.72.300.20.1.3.1.4 | ColumnseltCapacityUs | read-only | current | Total loop capacity in the upstream direction. |
| 1.3.6.1.4.1.193.72.300.20.1.3.1.5 | ColumnseltCapacityDs | read-only | current | Total loop capacity in the downstream direction. |
| 1.3.6.1.4.1.193.72.300.20.1.3.1.6 | ColumnseltTermination | read-only | current | Loop termination at customer side. The values between 6 and 254 are to be defined. |
| 1.3.6.1.4.1.193.72.300.20.1.3.1.7 | ColumnseltBasicReliability | read-only | current | Reliability of the parameters in the seltTestBasicOutputTable. The values between 7 and 255 are to be defined. |
| 1.3.6.1.4.1.193.72.300.20.1.3.1.8 | ColumnseltUSMeanNoiseLevel | read-only | current | The mean US noise level present on the line seen from IPDSLAM. |
| 1.3.6.1.4.1.193.72.300.20.1.3.1.9 | ColumnseltDSMeanNoiseLevel | read-only | current | The mean DS noise level present on the line seen from IPDSLAM. |
| 1.3.6.1.4.1.193.72.300.20.1.3.1.10 | ColumnseltAttenLimit | read-only | current | Reported maximum measurable/reliable attenuation @ 300 kHz. |
| 1.3.6.1.4.1.193.72.300.20.1.4 | TableseltTestAdvOutputTable | not-accessible | current | This table provides the advanced output parameters for the SELT test. |
| 1.3.6.1.4.1.193.72.300.20.1.4.1 | RowseltTestAdvOutputEntry | not-accessible | current | An entry contains the advanced output parameters for the SELT test for the subscriber line identified by lineIndex. |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.1 | ColumnseltEcho0 | read-only | current | Magnitude of the Echo Frequency Response of the line. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated th… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.2 | ColumnseltEcho1 | read-only | current | Magnitude of the Echo Frequency Response of the line. Part 1. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated th… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.3 | ColumnseltEcho2 | read-only | current | Magnitude of the Echo Frequency Response of the line. Part 2. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated th… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.4 | ColumnseltEcho3 | read-only | current | Magnitude of the Echo Frequency Response of the line. Part 3. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated th… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.5 | ColumnseltInsertionLoss0 | read-only | current | Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values s… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.6 | ColumnseltInsertionLoss1 | read-only | current | Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values s… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.7 | ColumnseltInsertionLoss2 | read-only | current | Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values s… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.8 | ColumnseltInsertionLoss3 | read-only | current | Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values s… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.9 | ColumnseltNoiseNe0 | read-only | current | Near-end line noise per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the value… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.10 | ColumnseltNoiseNe1 | read-only | current | Near-end line noise per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the value… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.11 | ColumnseltNoiseNe2 | read-only | current | Near-end line noise per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the value… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.12 | ColumnseltNoiseNe3 | read-only | current | Near-end line noise per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the value… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.13 | ColumnseltNoiseFe0 | read-only | current | Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the valu… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.14 | ColumnseltNoiseFe1 | read-only | current | Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the valu… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.15 | ColumnseltNoiseFe2 | read-only | current | Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the valu… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.16 | ColumnseltNoiseFe3 | read-only | current | Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the valu… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.17 | ColumnseltSnrNe0 | read-only | current | Signal to Noise ration per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the va… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.18 | ColumnseltSnrNe1 | read-only | current | Signal to Noise ration per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the va… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.19 | ColumnseltSnrNe2 | read-only | current | Signal to Noise ration per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the va… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.20 | ColumnseltSnrNe3 | read-only | current | Signal to Noise ration per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the va… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.21 | ColumnseltSnrFe0 | read-only | current | Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the … |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.22 | ColumnseltSnrFe1 | read-only | current | Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the … |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.23 | ColumnseltSnrFe2 | read-only | current | Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the … |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.24 | ColumnseltSnrFe3 | read-only | current | Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the … |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.25 | ColumnseltBitLoadingEstNe0 | read-only | current | Estimate of the maximum attainable load of bits per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTable… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.26 | ColumnseltBitLoadingEstNe1 | read-only | current | Estimate of the maximum attainable load of bits per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTable… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.27 | ColumnseltBitLoadingEstFe0 | read-only | current | Estimate of the maximum attainable load of bits per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTab… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.28 | ColumnseltBitLoadingEstFe1 | read-only | current | Estimate of the maximum attainable load of bits per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTab… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.29 | ColumnseltInsertionLoss4 | read-only | current | Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values s… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.30 | ColumnseltInsertionLoss5 | read-only | current | Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values s… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.31 | ColumnseltInsertionLoss6 | read-only | current | Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values s… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.32 | ColumnseltInsertionLoss7 | read-only | current | Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values s… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.33 | ColumnseltNoiseFe4 | read-only | current | Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the valu… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.34 | ColumnseltNoiseFe5 | read-only | current | Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the valu… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.35 | ColumnseltNoiseFe6 | read-only | current | Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the valu… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.36 | ColumnseltNoiseFe7 | read-only | current | Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the valu… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.37 | ColumnseltSnrFe4 | read-only | current | Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the … |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.38 | ColumnseltSnrFe5 | read-only | current | Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the … |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.39 | ColumnseltSnrFe6 | read-only | current | Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the … |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.40 | ColumnseltSnrFe7 | read-only | current | Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the … |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.41 | ColumnseltBitLoadingEstFe2 | read-only | current | Estimate of the maximum attainable load of bits per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTab… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.42 | ColumnseltBitLoadingEstFe3 | read-only | current | Estimate of the maximum attainable load of bits per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTab… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.43 | ColumnseltTDR0 | read-only | current | Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be int… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.44 | ColumnseltTDR1 | read-only | current | Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be int… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.45 | ColumnseltTDR2 | read-only | current | Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be int… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.46 | ColumnseltTDR3 | read-only | current | Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be int… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.47 | ColumnseltTDR4 | read-only | current | Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be int… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.48 | ColumnseltTDR5 | read-only | current | Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be int… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.49 | ColumnseltTDR6 | read-only | current | Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be int… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.50 | ColumnseltTDR7 | read-only | current | Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be int… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.51 | ColumnseltInputImpedance0 | read-only | current | Estimated input impedance of the line including far-end termination. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.52 | ColumnseltInputImpedance1 | read-only | current | Estimated input impedance of the line including far-end termination. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.53 | ColumnseltInputImpedance2 | read-only | current | Estimated input impedance of the line including far-end termination. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is… |
| 1.3.6.1.4.1.193.72.300.20.1.4.1.54 | ColumnseltInputImpedance3 | read-only | current | Estimated input impedance of the line including far-end termination. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is… |
| 1.3.6.1.4.1.193.72.300.20.1.10 | TableatmPvcTestInputTable | not-accessible | current | This table provides the input parameters for the ATM PVC test. |
| 1.3.6.1.4.1.193.72.300.20.1.10.1 | RowatmPvcTestInputEntry | not-accessible | current | An entry contains input parameters for the ATM PVC test for the subscriber line identified by lineIndex. |
| 1.3.6.1.4.1.193.72.300.20.1.10.1.1 | ColumnatmF5EndToEndLoopbackInterval | read-write | current | A number of 'ATM OAM F5 end-to-end loopback' cell(s) are sent with this interval on each PVC created for the subscriber line identified by lineIndex. The CPE m… |
| 1.3.6.1.4.1.193.72.300.20.1.10.1.2 | ColumnatmF5EndToEndLoopbackTimeout | read-write | current | Specifies the the maximum amount of time to wait for F5 replies for a batch. (The batch size is set in atmF5EndToEndBatchSize) |
| 1.3.6.1.4.1.193.72.300.20.1.10.1.3 | ColumnatmF5EndToEndLoopbackIntervalFine | read-write | current | A number of 'ATM OAM F5 end-to-end loopback' cell(s) are sent with this interval on each PVC created for the subscriber line identified by lineIndex. The CPE m… |
| 1.3.6.1.4.1.193.72.300.20.1.10.1.5 | ColumnatmF5EndToEndBatchSize | read-write | current | Specifies how many F5 cells that is be sent in an interval given by atmF5EndToEndLoopbackIntervalFine and atmF5EndToEndLoopbackInterval. |
| 1.3.6.1.4.1.193.72.300.20.1.10.1.6 | ColumnatmF5EndToEndBatchCount | read-write | current | Specifies how many batches that should be run before automatically stopping the test. Eg. A BatchCount of 4 and an interval of 3 seconds would run for 12 secon… |
| 1.3.6.1.4.1.193.72.300.20.1.12 | NodeatmPvcTestOutputTables | |||
| 1.3.6.1.4.1.193.72.300.20.1.12.1 | ScalaratmPvcTestOutputTableVpiIndex | not-accessible | current | The vpi index in atmPvcTestOutputTablePvc. |
| 1.3.6.1.4.1.193.72.300.20.1.12.2 | ScalaratmPvcTestOutputTableVciIndex | not-accessible | current | The vci index in atmPvcTestOutputTablePvc. |
| 1.3.6.1.4.1.193.72.300.20.1.12.4 | TableatmPvcTestOutputTableLine | not-accessible | current | This table provides the output parameters for the ATM PVC test (per line parameters). |
| 1.3.6.1.4.1.193.72.300.20.1.12.4.1 | RowatmPvcTestOutputEntryLine | not-accessible | current | An entry contains output parameters for the ATM PVC test for the subscriber line identified by lineIndex. |
| 1.3.6.1.4.1.193.72.300.20.1.12.4.1.1 | ColumnatmF5EndToEndBatchesLeft | read-only | current | If batches are used (defined with atmF5EndToEndBatchCount != 0) This counter states how many batches are left before all batches have been run. |
| 1.3.6.1.4.1.193.72.300.20.1.12.6 | TableatmPvcTestOutputTablePvc | not-accessible | current | This table provides the output parameters for the ATM PVC test (per pvc parameters). |
| 1.3.6.1.4.1.193.72.300.20.1.12.6.1 | RowatmPvcTestOutputEntryPvc | not-accessible | current | An entry contains output parameters for the ATM PVC test for the subscriber PVC identified by lineIndex, atmPvcTestOutputTableVpiIndex, and atmPvcTestOutputTab… |
| 1.3.6.1.4.1.193.72.300.20.1.12.6.1.1 | ColumnatmF5EndToEndTransmitted | read-only | current | Number of F5 cells transmitted on the PVC since the test was started with atmF5EndToEndLoopbackIntervalFine or atmF5EndToEndLoopbackInterval. |
| 1.3.6.1.4.1.193.72.300.20.1.12.6.1.2 | ColumnatmF5EndToEndReceived | read-only | current | Number of F5 cells received on the PVC since the test was started with atmF5EndToEndLoopbackIntervalFine or atmF5EndToEndLoopbackInterval. Note: F5 cells from … |
| 1.3.6.1.4.1.193.72.300.20.1.20 | TablepppoeTestInputTable | not-accessible | current | This table provides the input parameters for the 'PPP-over-Ethernet' test. Note: This OID has to be specified in 'adslIfTestType' in order to activate the test… |
| 1.3.6.1.4.1.193.72.300.20.1.20.1 | RowpppoeTestInputEntry | not-accessible | current | An entry contains input parameters for the 'PPP-over-Ethernet' test for the subscriber line identified by lineIndex. See also summary in pppoeTestInputTable. |
| 1.3.6.1.4.1.193.72.300.20.1.20.1.1 | ColumnpppoeServiceRequested | read-write | current | The ServiceName used in the PADI packets (PPPoE Active Discovery Initiation) during PPPoE tests (default empty). |
| 1.3.6.1.4.1.193.72.300.20.1.20.1.2 | ColumnpppoeVlanId | read-write | current | This is the VLANID used for the pppoeTest (accordingly to 802.1Q). The VLANID must have been configured for this line in the pvcTable. See also 'peaBridgeIpDsl… |
| 1.3.6.1.4.1.193.72.300.20.1.20.1.3 | ColumnpppoeTimeout | read-write | current | Specifies the the maximum amount of time to wait from the PADI packet is broadcasted until all replies (PADI packets) must have arrived. |
| 1.3.6.1.4.1.193.72.300.20.1.20.1.4 | ColumnpppoeInnerVlanId | read-write | current | This is the InnerVlanId used for the pppoeTest (accordingly to 802.1Q). This object is valid only if vlanTagType value is QinQ (Double Vlan). The innerVlanId m… |
| 1.3.6.1.4.1.193.72.300.20.1.21 | TablepppoeTestOutputTable | not-accessible | current | This table provides the **additional** output parameters for the 'PPP-over-Ethernet' test. The test result can be read in the generic 'adslIfTestResult' variab… |
| 1.3.6.1.4.1.193.72.300.20.1.21.1 | RowpppoeTestOutputEntry | not-accessible | current | An entry contains **additional** output parameters for the 'PPP-over-Ethernet' test for the subscriber line identified by lineIndex. Zero or more entries may e… |
| 1.3.6.1.4.1.193.72.300.20.1.21.1.1 | ColumnpppoeAccessConcentrator | read-only | current | The name of the Access Concentrator reported in a PADO packet. |
| 1.3.6.1.4.1.193.72.300.20.1.21.1.2 | ColumnpppoeServiceOffered | read-only | current | The name of a Service reported in a PADO packet from the Access Concentrator. |
| 1.3.6.1.4.1.193.72.300.20.1.21.1.3 | ColumnresultIndex | not-accessible | current | Indicates the entry number for a line. |
| 1.3.6.1.4.1.193.72.300.20.1.23 | TableloopDiagResultTable | not-accessible | current | This table provides the per line results of the ADSL2 Loop Diagnostics. |
| 1.3.6.1.4.1.193.72.300.20.1.23.1 | RowloopDiagResultEntry | not-accessible | current | An entry contains the per line results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.1 | ColumnloopDiagStatus | read-only | current | Status of current Loop Diagnostics. NOTE that Loop Diagnostics data are only valid in case of status LoopDiagSuccess. |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.2 | ColumnloopDiagAttainableBitRateNE | read-only | current | Near-end attainable bit rate in bit per second (bps). Compliant to G.997.1: 7.5.1.13 (ATTNDRus). |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.3 | ColumnloopDiagLoopAttenuationNE | read-only | current | Near-end loop attenuation. Range is [1023..0], unit is 0.1 dB. LoopAttenuation = 1023 is a special value indicating that the loop attenuation is outside the re… |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.4 | ColumnloopDiagSignalAttenuationNE | read-only | current | Near-end signal attenuation. Range is [1023..0], unit is 0.1 dB. SignalAttenuation = 1023 is a special value indicating that the attenuation is outside the rep… |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.5 | ColumnloopDiagSnrMarginNE | read-only | current | Near-end signal-to-noise ratio margin. Range is [511..-512], unit is 0.1 dB. snrMargin = -512 is a special value indicating that the signal-to-noise ratio marg… |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.6 | ColumnloopDiagActualTxPowerFarEndNE | read-only | current | The far-end actual aggregate transmit power as determined by the near-end receive PMD function. Range is [511..-512], unit is 0.1 dBm. actualTxPowerFE = -512 i… |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.7 | ColumnloopDiagAttainableBitRateFE | read-only | current | Far-end attainable bit rate in bit per second (bps). Compliant to G.997.1: 7.5.1.12 (ATTNDRds). |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.8 | ColumnloopDiagLoopAttenuationFE | read-only | current | Far-end loop attenuation. Range is [1023..0], unit is 0.1 dB. LoopAttenuation = 1023 is a special value indicating that the attenuation is outside the represen… |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.9 | ColumnloopDiagSignalAttenuationFE | read-only | current | Far-end signal attenuation. Range is [1023..0], unit is 0.1 dB. SignalAttenuation = 1023 is a special value indicating that the attenuation is outside the repr… |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.10 | ColumnloopDiagSnrMarginFE | read-only | current | Far-end signal-to-noise ratio margin. Range is [511..-512], unit is 0.1 dB. SnrMargin = -512 is a special value indicating that the signal-to-noise ratio margi… |
| 1.3.6.1.4.1.193.72.300.20.1.23.1.11 | ColumnloopDiagActualTxPowerFarEndFE | read-only | current | The near-end actual aggregate transmit power as determined by the far-end receive PMD function. Range is [511..-512], unit is 0.1 dBm. ActualTxPowerFE = -512 i… |
| 1.3.6.1.4.1.193.72.300.20.1.24 | TableloopDiagHlinNeTable | not-accessible | current | This table provides the per subcarrier Hlin results of the ADSL2 Loop Diagnostics. The linear complex channel transfer function values for the tone range speci… |
| 1.3.6.1.4.1.193.72.300.20.1.24.1 | RowloopDiagHlinNeEntry | not-accessible | current | An entry contains the per subcarrier Hlin results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. NOTE Low designates the first … |
| 1.3.6.1.4.1.193.72.300.20.1.24.1.1 | ColumnloopDiagHlinNeScale | read-only | current | Scale factor for the normalized complex numbers Hlin. |
| 1.3.6.1.4.1.193.72.300.20.1.24.1.2 | ColumnloopDiagHlinNeLow | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Bytes n*4 + [0..1]: Real part (int16) Bytes n*4 + [2..3]: Imagi… |
| 1.3.6.1.4.1.193.72.300.20.1.24.1.3 | ColumnloopDiagHlinNeHigh | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Bytes n*4 + [0..1]: Real part (int16) Bytes n*4 + [2..3]: Imagi… |
| 1.3.6.1.4.1.193.72.300.20.1.25 | TableloopDiagHlinFeTable | not-accessible | current | This table provides the per subcarrier Hlin results of the ADSL2 Loop Diagnostics. The linear complex channel transfer function values for the tone range speci… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1 | RowloopDiagHlinFeEntry | not-accessible | current | An entry contains the per subcarrier Hlin results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. NOTE: The partId specifies the… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.1 | ColumnloopDiagHlinFeScalePart0 | read-only | current | Scale factor for the normalized complex numbers Hlin. |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.2 | ColumnloopDiagHlinFeScalePart1 | read-only | current | Scale factor for the normalized complex numbers Hlin. |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.3 | ColumnloopDiagHlinFeScalePart2 | read-only | current | Scale factor for the normalized complex numbers Hlin. |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.4 | ColumnloopDiagHlinFeScalePart3 | read-only | current | Scale factor for the normalized complex numbers Hlin. |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.5 | ColumnloopDiagHlinFeScalePart4 | read-only | current | Scale factor for the normalized complex numbers Hlin. |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.6 | ColumnloopDiagHlinFeScalePart5 | read-only | current | Scale factor for the normalized complex numbers Hlin. |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.7 | ColumnloopDiagHlinFeScalePart6 | read-only | current | Scale factor for the normalized complex numbers Hlin. |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.8 | ColumnloopDiagHlinFeScalePart7 | read-only | current | Scale factor for the normalized complex numbers Hlin. |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.9 | ColumnloopDiagHlinFePart0Low | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.10 | ColumnloopDiagHlinFePart0High | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.11 | ColumnloopDiagHlinFePart1Low | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.12 | ColumnloopDiagHlinFePart1High | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.13 | ColumnloopDiagHlinFePart2Low | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.14 | ColumnloopDiagHlinFePart2High | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.15 | ColumnloopDiagHlinFePart3Low | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.16 | ColumnloopDiagHlinFePart3High | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.17 | ColumnloopDiagHlinFePart4Low | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.18 | ColumnloopDiagHlinFePart4High | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.19 | ColumnloopDiagHlinFePart5Low | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.20 | ColumnloopDiagHlinFePart5High | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.21 | ColumnloopDiagHlinFePart6Low | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.22 | ColumnloopDiagHlinFePart6High | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.23 | ColumnloopDiagHlinFePart7Low | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.24 | ColumnloopDiagHlinFePart7High | read-only | current | The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int… |
| 1.3.6.1.4.1.193.72.300.20.1.26 | TableloopDiagHlogTable | not-accessible | current | This table provides the per subcarrier Hlog results of the ADSL2 Loop Diagnostics. Hlog is calculated from the given values, as follows: Hlog[i] = 6 - hlogNE(i… |
| 1.3.6.1.4.1.193.72.300.20.1.26.1 | RowloopDiagHlogEntry | not-accessible | current | An entry contains the per subcarrier Hlog results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. NOTE: The partId specifies the… |
| 1.3.6.1.4.1.193.72.300.20.1.26.1.1 | ColumnloopDiagHlogNE | read-only | current | The near-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]:… |
| 1.3.6.1.4.1.193.72.300.20.1.26.1.2 | ColumnloopDiagHlogFEPart0Low | read-only | current | The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: … |
| 1.3.6.1.4.1.193.72.300.20.1.26.1.3 | ColumnloopDiagHlogFEPart0High | read-only | current | The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: … |
| 1.3.6.1.4.1.193.72.300.20.1.26.1.4 | ColumnloopDiagHlogFEPart1Low | read-only | current | The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: … |
| 1.3.6.1.4.1.193.72.300.20.1.26.1.5 | ColumnloopDiagHlogFEPart1High | read-only | current | The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: … |
| 1.3.6.1.4.1.193.72.300.20.1.26.1.6 | ColumnloopDiagHlogFEPart2Low | read-only | current | The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: … |
| 1.3.6.1.4.1.193.72.300.20.1.26.1.7 | ColumnloopDiagHlogFEPart2High | read-only | current | The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: … |
| 1.3.6.1.4.1.193.72.300.20.1.26.1.8 | ColumnloopDiagHlogFEPart3Low | read-only | current | The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: … |
| 1.3.6.1.4.1.193.72.300.20.1.26.1.9 | ColumnloopDiagHlogFEPart3High | read-only | current | The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: … |
| 1.3.6.1.4.1.193.72.300.20.1.27 | TableloopDiagQlnTable | not-accessible | current | This table provides the per subcarrier Qln results of the ADSL2 Loop Diagnostics. QLN is calculated from the given values as follows: QLN[i] = -23 - (n[i]/2)(d… |
| 1.3.6.1.4.1.193.72.300.20.1.27.1 | RowloopDiagQlnEntry | not-accessible | current | An entry contains the per subcarrier Qln results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. NOTE: The partId specifies the … |
| 1.3.6.1.4.1.193.72.300.20.1.27.1.1 | ColumnloopDiagQlnNE | read-only | current | The near-end quiet line noise PSD. Range is [255..0]. The value 255 indicates no measurement available. |
| 1.3.6.1.4.1.193.72.300.20.1.27.1.2 | ColumnloopDiagQlnFEPart0Low | read-only | current | The far-end quiet line noise PSD. Range is [255..0]. The value 255 indicates no measurement available. |
| 1.3.6.1.4.1.193.72.300.20.1.27.1.3 | ColumnloopDiagQlnFEPart0High | read-only | current | The far-end quiet line noise PSD. Range is [255..0]. The value 255 indicates no measurement available. |
| 1.3.6.1.4.1.193.72.300.20.1.27.1.4 | ColumnloopDiagQlnFEPart1Low | read-only | current | The far-end quiet line noise PSD. Range is [255..0]. The value 255 indicates no measurement available. |
| 1.3.6.1.4.1.193.72.300.20.1.27.1.5 | ColumnloopDiagQlnFEPart1High | read-only | current | The far-end quiet line noise PSD. Range is [255..0]. The value 255 indicates no measurement available. |
| 1.3.6.1.4.1.193.72.300.20.1.28 | TableloopDiagSnrTable | not-accessible | current | This table provides the per subcarrier Snr results of the ADSL2 Loop Diagnostics. SNR is calculated from the given values as follows: SNR[i] = -32 + (n[i]/2)(d… |
| 1.3.6.1.4.1.193.72.300.20.1.28.1 | RowloopDiagSnrEntry | not-accessible | current | An entry contains the per subcarrier Snr results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. NOTE: The partId specifies the … |
| 1.3.6.1.4.1.193.72.300.20.1.28.1.1 | ColumnloopDiagSnrNE | read-only | current | The near-end signal-to-noise ratio. Range is [255..0]. The value 255 indicates no measurement available. |
| 1.3.6.1.4.1.193.72.300.20.1.28.1.2 | ColumnloopDiagSnrFEPart0Low | read-only | current | The far-end signal-to-noise ratio. Range is [255..0]. The value 255 indicates no measurement available. |
| 1.3.6.1.4.1.193.72.300.20.1.28.1.3 | ColumnloopDiagSnrFEPart0High | read-only | current | The far-end signal-to-noise ratio. Range is [255..0]. The value 255 indicates no measurement available. |
| 1.3.6.1.4.1.193.72.300.20.1.28.1.4 | ColumnloopDiagSnrFEPart1Low | read-only | current | The far-end signal-to-noise ratio. Range is [255..0]. The value 255 indicates no measurement available. |
| 1.3.6.1.4.1.193.72.300.20.1.28.1.5 | ColumnloopDiagSnrFEPart1High | read-only | current | The far-end signal-to-noise ratio. Range is [255..0]. The value 255 indicates no measurement available. |
| 1.3.6.1.4.1.193.72.300.20.2 | NodepeaTestIpDslamTraps | |||
| 1.3.6.1.4.1.193.72.300.20.2.0 | NodepeaTestIpDslamTrapsEntry | |||
| 1.3.6.1.4.1.193.72.300.20.2.0.1 | NotificationifTestCompletion | current | Indicates that the test is ready. Valid from: EDA 1.1R2A Parameters 1: Managed object class IP DSLAM Port 2: Managed object ID (MAC + PortNo) 3: Sequence numbe… | |
| 1.3.6.1.4.1.193.72.300.20.3 | NodepeaTestIpDslamObjectsGroups | |||
| 1.3.6.1.4.1.193.72.300.20.3.1 | GrouppeaTestIpDslamObjectsGroup | current | Objects for the fssServiceLine Group | |
| 1.3.6.1.4.1.193.72.300.20.4 | NodepeaTestIpDslamTrapsGroups | |||
| 1.3.6.1.4.1.193.72.300.20.4.2 | GrouppeaTestIpDslamTrapsGroup | current | Deprecated Notifications Group |