MIB Viewer

RS-XX8000-DVB-TX-MIB

576 objects
This MIB defines transmitting systems from Rohde & Schwarz. Use this MIB if your system meets the following requirements: - series XX8000 (NetCCU800), - DVB, - transmitter reserve concept SingleTx, DualDrive, Active Reserve or Passive Reserve. The following MIBs are related to this: - RS-COMMON-MIB - mandatory for this MIB - RS-XX8000-COMMON-MIB - mandatory for this MIB
OIDNameAccessStatusDescription
1.3.6.1.4.1.2566.127.1.2.167.4IdentityrsXx8000DvbTxcurrentXx8000 DVB transmitter.
1.3.6.1.4.1.2566.127.1.2.167.4.1NodersXx8000DvbTxObjs
1.3.6.1.4.1.2566.127.1.2.167.4.1.1TablecommandsTxTablenot-accessiblecurrentThis table contains important commands for the transmitter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1RowcommandsTxEntrynot-accessiblecurrentAn entry for a designated transmitter and device.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.1ColumncmdTxResetSumFaultread-writecurrentReset all faults (in all modules) of the transmitter. You reset a designated transmitter (NetCCU, Exciters, Outputstages). An equivalent would be pressing RESE…
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.2ColumncmdTxParametersetLoadread-writecurrentThis loads the desired parameter set.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.3ColumncmdTxParametersetSaveread-writecurrentThis saves the current settings to a designated parameter set.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.4ColumncmdTxParametersetReSaveread-writeobsoleteThis saves the changes to the current parameter set.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.5ColumncmdTxOperationModeProgramread-writecurrentThis switches the program path of the transmitter on/off.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.6ColumncmdTxOperationModeReserveread-writecurrentThis switches the reserve path of the transmitter on/off.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.7ColumncmdTxOpModeExcAutomaticread-writecurrentThis switches the exciter automatic on/off.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.8ColumncmdTxOpModeOstAutomaticread-writecurrentThis switches the outputstage automatic on/off. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.9ColumncmdTxPreselectExciterread-writecurrentThis sets exciterA or exciterB to program path (antenna) of the transmitter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.10ColumncmdTxPreselectOutputstageread-writecurrentThis sets - outputstageA or - outputstageB or - both to program path (antenna) of the transmitter, or it sets both to dummyload. The settings bothToAntenna(3) …
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.11ColumncmdTxDelayTimeExcAutomaticread-writecurrentThis sets the exciter automatic delay time.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.12ColumncmdTxDelayTimeOstAutomaticread-writecurrentThis sets the outputstage automatic delay time. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.13ColumncmdTxRfSwitchread-writecurrentRF switch for single-ended systems.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.15ColumncmdTxSystemModeread-writecurrentThis object gives you the possibility of switching the TV standard of a whole system with NetCCU with only one command. Not applicable for N+1 or NTx systems. …
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.20ColumncmdTxProgramExciterPrioread-writecurrentEnables/Disables priority usage of program exciter
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.21ColumncmdTxChangeOverread-writecurrentPerforms a change over
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.22ColumncmdTxSwitchPositionread-onlycurrentShows the actual switch position. The program exciter is connected to input 1 (RF IN 1), the control exciter is connected to input 2 (RF IN 2) of the base ampl…
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.30ColumncmdDeviceIdxnot-accessiblecurrentThis column is used to show parameters for both exiters, if you have dualdrive transmitters.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.31ColumncmdExcOpModeInputAutomaticread-writecurrentActivates/deactivates the input automatic. If input automatic is active and a loss of input signal is detected on the current input the reserve input will be u…
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.32ColumncmdExcPreselectInputread-writecurrentThis sets the preselection of a transmitters input.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.33ColumncmdExcModeread-writecurrentSwitch between DVB-T and DVB-H.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.34ColumncmdExcNetworkModeread-writecurrentSwitch between Single Frequency Networks (SFN) and Multiple Frequency Networks (MFN).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.35ColumncmdExcTPSSourceread-writecurrentTransmitted TPS parameters can be adjusted manually inside the transmitter or automatically via MIP from the SFN adaptor.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.36ColumncmdExcEnableCellIDread-writecurrentThis enables the Cell ID insertion. The length indicator will be adjusted.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.37ColumncmdExcTxAddressread-writecurrentThis is the unique address of the transmitter to reference specific settings in the MIP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.38ColumncmdExcTxAutomaticread-writecurrentThis enables Tx specific parameters from the MIP data caroussel (e.g. time offset, frequency offset).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.39ColumncmdExcInputAutoSwitchread-writedeprecatedActivates/deactivates the input automatic. If input automatic is active and a loss of input signal is detected on the current input the reserve input will be u…
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.40ColumncmdExcInputSeamlessread-writecurrentIf the datastreams on both inputs are syncronised a seamless switch is possible. With this parameter the seamless switch can be suppressed to enable a check of…
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.41ColumncmdExcInputPriorityread-writecurrentEqual: There are no differences between both inputs. If a failure on the current input is detected it will be switched to the reserve input. It stays there unt…
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.42ColumncmdExcInputCheckTimeForwardread-writecurrentThis time has to elapse before the current input switches to the reserve input.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.43ColumncmdExcInputCheckTimeSwitchbackread-writecurrentThis time has to elapse before the automatic switches back from the reserve to a preselected input. This value has no effect if the priority is set to equal.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.44ColumncmdExcInputMuteOnFailread-writecurrentIf a loss of input signal is detected, the exciter mutes.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.45ColumncmdExcInputManualPreseletionHP1read-writecurrentThe data format of the input can be detected automatically or can be set manually to ASI or SMPTE.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.46ColumncmdExcInputManualPreseletionHP2read-writecurrentThe data format of the input can be detected automatically or can be set manually to ASI or SMPTE.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.47ColumncmdExcInputManualPreseletionLP1read-writecurrentThe data format of the input can be detected automatically or can be set manually to ASI or SMPTE.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.48ColumncmdExcInputManualPreseletionLP2read-writecurrentThe data format of the input can be detected automatically or can be set manually to ASI or SMPTE.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.49ColumncmdExcTPSManualBandwidthread-writecurrentThe bandwidth used by the RF channel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.50ColumncmdExcTPSManualFFTLengthread-writecurrentThe used FFT length (depends on the DVB network).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.51ColumncmdExcTPSManualGuardIntervalread-writecurrentThe Guard interval affects the error correction in multipath receiving situations. A long Guard Interval reduces the amount of payload data.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.52ColumncmdExcTPSManualConstellationread-writecurrentThis parameter sets the modulation mode.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.53ColumncmdExcTPSManualAlpharead-writeobsoleteAn alpha greater than noHierarchy(1) enables the hierarchical coding mode.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.54ColumncmdExcTPSManualCellIDread-writecurrentVia Cell ID the receiver knows the current network.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.55ColumncmdExcTPSManualInterleaverread-writecurrentEnables the bit interleaver for hierarchical coding
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.56ColumncmdExcTPSManualCoderateHPread-writecurrentThe Code Rate sets the ratio between payload and error correction information.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.57ColumncmdExcTPSManualCoderateLPread-writecurrentThe Code Rate sets the ratio between payload and error correction information.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.58ColumncmdExcTPSManualTimeSlicingHPread-writecurrentEnables the time slicing for hierarchical coding.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.59ColumncmdExcTPSManualTimeSlicingLPread-writecurrentEnables the time slicing for hierarchical coding.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.60ColumncmdExcTPSManualFECHPread-writecurrentEnables the forward error correction (FEC) for hierarchical coding.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.61ColumncmdExcTPSManualFECLPread-writecurrentEnables the forward error correction (FEC) for hierarchical coding.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.62ColumncmdExcSFNStaticDelayread-writecurrentA constant adjustable delay for tuning a SFN (-999999.9 ... 999999.9).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.63ColumncmdExcSFNDeviationTimeread-writecurrentLeap In Time. This parameter sets the deviation in time when a readjustment of the dynamic delay is necessary.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.64ColumncmdExcFrequencyread-writecurrentThis is the RF frequency.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.65ColumncmdExcReferenceSourceread-writecurrentThe Source of the reference signal. The value internGPS is not valid for SX800.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.66ColumncmdExcMuteOnPPSFailread-writecurrentSelect the behaviour if the external second pulse is not available.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.67ColumncmdExcMuteOnReferenceFailread-writecurrentSelect the behaviour if the external reference is not available.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.68ColumncmdExcRefFailDelayTimeread-writecurrentAdjusts the time after the RF will be muted in case of a reference problem. Zero hours means react immediately.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.69ColumncmdExcTypeLossOfInputread-writecurrentIf the input signal is lost, either a warning or a fault can be generated. If you select fault here, a switchover to the reserve exciter will be executed when …
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.70ColumncmdExcRfOutputread-writecurrentTurns on/switches off the output signal. This switch takes the same effect as the switch on the frontpanel of the exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.71ColumncmdExcRfOutputRegulationread-writecurrentTurns on/switches off the automatic output level regulation.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.72ColumncmdExcRfOutputManualRfLevelread-writecurrentAdjusts the RF level (0.0 ... 100.0). The value relates to an attenuation of 0 dB.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.73ColumncmdExcRfOutputAttenuationread-writecurrentActivates internal attenuators to reduce the output level of the exciter. Adjustable in steps of 3 dB only.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.74ColumncmdExcRfOutputRfSloperead-writecurrentAdjusts a slope in the RF signal (-50.0 ... 50.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.75ColumncmdExcRfOutputModulationSloperead-writecurrentModulation slope (-50.0 ... 50.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.77ColumncmdExcRfIqAdjustStartread-writecurrentStarts the automatic IQ adjustment. It works for the current used local 1 frequency and lasts up to 5 minutes. In this time the output will be muted. During th…
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.78ColumncmdExcRfIqAdjustTestsignalread-writecurrentGenerates a test signal to adjust the IQ modulation. It is necessary to disconnect the rf-cable to the output stages.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.79ColumncmdExcRfIqAdjustBiasCoarseIread-writecurrentAdjusts the offset for I in huge steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.80ColumncmdExcRfIqAdjustBiasCoarseQread-writecurrentAdjusts the offset for Q in huge steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.81ColumncmdExcRfIqAdjustBiasFineIread-writecurrentAdjusts the offset for I in small steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.82ColumncmdExcRfIqAdjustBiasFineQread-writecurrentAdjusts the offset for Q in small steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.83ColumncmdExcRfIqAdjustGainIread-writecurrentAdjusts the gain for I in small steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.84ColumncmdExcRfIqAdjustGainQread-writecurrentAdjusts the gain for Q in small steps.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.85ColumncmdExcRfIqAdjustPhaseread-writecurrentAdjusts the phase between I and Q (-14.000 ... 14.000).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.86ColumncmdExcInput1Sourceread-writecurrentSource for input 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.87ColumncmdExcInput2Sourceread-writecurrentSource for input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.88ColumncmdExcInpAutoReadyAfterChangeOvread-writecurrentInput automatic ready after change over.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.89ColumncmdExcInputFailDelayTimeread-writecurrentThe time between detecting a loss of input signal and displaying a failure.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.90ColumncmdExcTransmitterTyperead-writecurrentthe TV standard of the transmitter The transmitter is rebooted automatically when the TV standard is changed. Signal processing is also switched over.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.91ColumncmdExcTimeSchedulerread-writecurrentIf on, the time scheduler controls the tx type. When switching on the scheduler it may instantly set the correct TV standard and reboot the device.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.92ColumncmdExcMuteConditionread-writecurrentWhen notBeforeSyncLoss(2) is selected, it relativizes the cmdExcInputMuteOnFail setting mute(1): If a DVB receiver is the last valid input, an existing transpo…
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.97ColumncmdExcRfWarningLimitread-writecurrentWarning limit for the RF control. min: -15.0, max: 0.0
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.98ColumncmdExcRfFailLimitread-writecurrentFault limit for the RF control. min: -15.0, max: 0.0
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.99ColumncmdExcOutputPowerread-writecurrentamplifier output power 0 ... 400 W
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.100ColumncmdOstRefVoltageVisionread-writecurrentThis adjusts the output power of the amplifier. This value is settable with maximal 1 position after point (example 11.2).
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.101ColumncmdOstMaxOutletTempThresholdread-writecurrentThis sets the threshold for the outlet temperature.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.110ColumncmdExcMonitoringOutputread-writecurrentSelects which signal appears at the monitoring output.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.111ColumncmdExcOcxoAdjustread-writecurrentAdjusts the frequency of the internal 10 MHz reference. This value only takes effect if the reference source 'internal' is selected.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.112ColumncmdExcExpectInputReserveread-writecurrentIf on(1) the warning txExcInputReseveMissing will be generated in case second input is missing.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.113ColumncmdExcEnablePcrResetread-writeobsoleteEnables/disables daily PCR resets. This option is valid only in MFN operation. The reset time is given in cmdExcTimeForDailyPcrReset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.114ColumncmdExcTimeForDailyPcrResetread-writeobsoleteSets the time of day for daily PCR reset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.1.1.115ColumncmdExcFailDelayModeread-writecurrentCondition when the fail delay time is used.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2NodesummaryInfo
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.1ScalarsummaryFaultTxread-onlycurrentThis indicates a summary fault of the transmitter. true(1) false(2) There is a fault of at least one module (e.g. Exciter) which causes this summary fault. An …
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.2ScalarsummaryWarningTxread-onlycurrentThis indicates a summary warning of the transmitter. true(1) false(2) There is a fault of at least one module (e.g. Exciter) which causes this summary warning.…
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.3ScalarlocalModeTxread-onlycurrentThis indicates the local/remote-mode of the transmitter. true(1) false(2) The transmitter is eigther in local-mode or in remote-mode. For security reasons it i…
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.4ScalarrfOnTxread-onlycurrentThe RF is present for the corresponding transmitter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.5ScalarforwardPowerread-onlycurrentThe measured forwarded power [W] of the transmitter. For Active Reserve systems it is the sum of both outputstages.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.6ScalarreflectedPowerread-onlycurrentThe measured reflected power [W] of the transmitter. For Active Reserve systems it is the sum of both outputstages. Not available for lowpower systems.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.7ScalarsummaryFaultExcAread-onlycurrentThis indicates a summary fault of exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.8ScalarsummaryFaultOstAread-onlycurrentThis indicates a summary fault of outputstage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.9ScalarsummaryFaultExcBread-onlycurrentThis indicates a summary fault of exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.10ScalarsummaryFaultOstBread-onlycurrentThis indicates a summary fault of outputstage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.11ScalarexciterAutomaticReadyread-onlycurrentThe Exciter Automatic is Ready. In case of any fault on one exciter, there will be a switchover to the other exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.12ScalarexciterAutomaticChangedread-onlycurrentThe Exciter Automatic has changed. There was a fault on one exciter which lead to this changeover.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.13ScalarexciterAutomaticFaultread-onlycurrentThe Exciter Automatic is faulty. In case of any fault on one exciter, there will be no switchover to the other exciter, because of this fault.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.14ScalaroutputstageAutomaticReadyread-onlycurrentThe Outputstage Automatic is Ready. In case of any fault on one outputstage, there will be a switchover to the other outputstage. This paramter is only availab…
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.15ScalaroutputstageAutomaticChangedread-onlycurrentThe Outputstage Automatic has changed. There was a fault on one outputstage which lead to this changeover. This paramter is only available for systems with an …
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.16ScalaroutputstageAutomaticFaultread-onlycurrentThe Outputstage Automatic is faulty. In case of any fault on one outputstage, there will be no switchover to the other outputstage, because of this fault. This…
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.17ScalarnoConnectionExcAread-onlycurrentNo Connection between NetCCU and Exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.18ScalarnoConnectionOstAread-onlycurrentNo Connection between NetCCU and Outputstage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.19ScalarnoConnectionExcBread-onlycurrentNo Connection between NetCCU and Exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.20ScalarnoConnectionOstBread-onlycurrentNo Connection between NetCCU and Outputstage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.21ScalaractiveExcAread-onlycurrentExciterA is currently active.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.22ScalaractiveOstAread-onlycurrentOutputstageA is currently active.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.23ScalaractiveExcBread-onlycurrentExciterB is currently active.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.24ScalaractiveOstBread-onlycurrentOutputstageB is currently active.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.25ScalarforwardPowerOstAread-onlycurrentThe measured forwarded power [W] of the OutputstageA.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.26ScalarreflectedPowerOstAread-onlycurrentThe measured reflected power [W] of the OutputstageA. Not available for lowpower systems.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.27ScalarforwardPowerOstBread-onlycurrentThe measured forwarded power [W] of the OutputstageB.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.28ScalarreflectedPowerOstBread-onlycurrentThe measured reflected power [W] of the OutputstageB. Not available for lowpower systems.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.29ScalarpowerSupplyread-onlycurrentMonitoring value of the output voltages of the power supply.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.30ScalaradditionalPowerSupplyread-onlycurrentShows whether the NetCCU has an additional (external) power supply.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.31ScalarinternalPowerSupplyread-onlycurrentMonitoring value of the output voltages of the internal power supply.
1.3.6.1.4.1.2566.127.1.2.167.4.1.2.32ScalarexternalPowerSupplyread-onlycurrentMonitoring value of the output voltages of the external power supply.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3NodedetailedInfo
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2TableexcInputTablenot-accessiblecurrentA table for more detailed information about the exciter. These values are all read-only. For settings, refer to commands.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1RowexcInputEntrynot-accessiblecurrentAn entry for a designated input channel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.1ColumnexcInputExcIdxnot-accessiblecurrentThe index for exciterA (and exciterB if there are DualDrive systems).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.2ColumnexcInputChannelIdxnot-accessiblecurrentThe index for the different input channels.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.3ColumnexcInputChannelNameread-onlycurrentThis is the logical name for the index for the different input channels.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.4ColumnexcInputConnectedread-onlycurrentThe input channel is connected.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.5ColumnexcInputSeamlessread-onlycurrentThe input channel is in seamless mode.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.6ColumnexcInputPreselectedread-onlycurrentThe input channel is the preselected.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.7ColumnexcInputActiveread-onlycurrentThe input channel is active.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.8ColumnexcInputMipFailread-onlycurrentInput channel MIP fail.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.9ColumnexcInputBandwidthread-onlycurrentThe bandwidth used by the input channel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.10ColumnexcInputFFTLengthread-onlycurrentThe used FFT length (depends on the DVB network).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.11ColumnexcInputGuardIntervalread-onlycurrentThe Guard interval affects the error correction in multipath receiving situations. A long Guard Interval reduces the amount of payload data.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.12ColumnexcInputConstellationread-onlycurrentThis parameter sets the modulation mode.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.13ColumnexcInputAlpharead-onlyobsoleteAn alpha greater than zero enables the hierarchical coding mode.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.14ColumnexcInputCellIDread-onlycurrentVia Cell ID the receiver knows the current network.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.15ColumnexcInputInterleaverread-onlycurrentEnables the bit interleaver for hierarchical coding
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.16ColumnexcInputCodeRateread-onlycurrentCoderate can be set separately for HP and LP channel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.17ColumnexcInputPacketLengthread-onlycurrentThe Packet length for the channel.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.18ColumnexcInputMeasuredDatarateread-onlycurrentThe measured datarate of the input.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.19ColumnexcInputRequiredDatarateread-onlycurrentThe required datarate of the input.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.2.1.20ColumnexcInputMaximumDelayread-onlycurrentPeriod of time between the signal leaving the play-out center (MIP inserter) and its regular transmission at the antenna. This delay is set in the MIP inserter…
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3TableostTablenot-accessiblecurrentThe table of racks.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1RowostEntrynot-accessiblecurrentA row (an entry) for one rack.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.1ColumnostIdxnot-accessiblecurrentThe dedicated outputstage (A/B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.2ColumnostRackIdxnot-accessiblecurrentThe rack number (1..10).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.3ColumnostRackInletTemperatureread-onlycurrentThe inlet temperature.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.4ColumnostRackOutletTemperatureread-onlycurrentThe outlet temperature.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.5ColumnostRackAuxPowerSupplyread-onlycurrentControl voltage of auxiliary power supply of the designated rack. The value should be between 11.1 to 13.2 V.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.400ColumnostRackAmpIdxnot-accessiblecurrentAmplifier Index
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.401ColumnostRackAmpI1Aread-onlycurrentThe power amplifier module current (I_1A).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.402ColumnostRackAmpI2Aread-onlycurrentThe power amplifier module current (I_2A).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.403ColumnostRackAmpI3Aread-onlycurrentThe power amplifier module current (I_3A).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.404ColumnostRackAmpI4Aread-onlycurrentThe power amplifier module current (I_4A).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.405ColumnostRackAmpI1Bread-onlycurrentThe power amplifier module current (I_1B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.406ColumnostRackAmpI2Bread-onlycurrentThe power amplifier module current (I_2B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.407ColumnostRackAmpI3Bread-onlycurrentThe power amplifier module current (I_3B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.408ColumnostRackAmpI4Bread-onlycurrentThe power amplifier module current (I_4B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.409ColumnostRackAmpIDrvread-onlycurrentThe driver module current (I_DRV).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.410ColumnostRackAmpUDcread-onlycurrentThe power amplifier supply voltage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.411ColumnostRackAmpIDcread-onlycurrentThe power amplifier supply current.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.412ColumnostRackAmpUDcControlread-onlycurrentThe power supply control voltage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.413ColumnostRackAmpURegread-onlycurrentThe power amplifier AGC voltage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.414ColumnostRackAmpPowerAread-onlycurrentThe voltage power detector A.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.415ColumnostRackAmpPowerBread-onlycurrentThe voltage power detector B.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.416ColumnostRackAmpPowerOutread-onlycurrentThe voltage forward power detector.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.417ColumnostRackAmpPowerReflectionread-onlycurrentThe voltage reflected power detector.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.418ColumnostRackAmpPowerReferenceread-onlycurrentThe reference voltage for output power.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.419ColumnostRackAmpDeltaPhaseread-onlycurrentThe measured phase delta for output power.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.3.1.420ColumnostRackAmpCmdDeltaPhaseread-writecurrentThe phase delta setting for output power. The range is -50.0% to 50.0%.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20TableexciterStatusTablenot-accessiblecurrentExciter status values.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1RowexciterStatusEntrynot-accessiblecurrentA row (an entry) for one exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.3ColumnexcStatusExcIdxnot-accessiblecurrentThe dedicated exciter (A/B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.4ColumnexcStatusRfOutputAgcRegulationread-onlycurrentShows the operating point of the RF regulator. The shown value should be around 50 per cent.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.5ColumnexcStatusRfIqAdjustAutoread-onlycurrentAutomatic I/Q-Adjust.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.6ColumnexcStatusRfIqAdjustLO1Frequencyread-onlycurrentModulator LO1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.7ColumnexcStatusNominalPowerread-writecurrentDescription.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.9ColumnexcStatusVSWRread-onlycurrentVoltage Standing Wave Ratio
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.13ColumnexcStatusSfnDelayProcessingread-onlycurrentThe Minimum signal transmit time through the exciter. This delay depends on the DVB transmission parameters.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.14ColumnexcStatusSfnDelayDynamicread-onlycurrentThe period of time by which signal processing is artificially delayed so that the desired time of transmission is obtained.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.15ColumnexcStatusSfnDelayNetworkread-onlycurrentThe signal propagation time between the play-out center (MIP inserter) and the exciter input. This delay depends on the transmission path used.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.16ColumnexcStatusSfnDelayTxOffsetread-onlycurrentAn individual transmitter specific delay. It can be adjusted via data carousel of the SFN adapter. It is true for a specific transmitter address.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.17ColumnexcStatusSfnDelayMaximumread-onlycurrentThe period of time between the signal leaving the play-out center (MIP inserter) and its regular transmission at the antenna. This delay is set in the MIP inse…
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.18ColumnexcStatusSfnDelayTotalread-onlycurrentThe actual signal transit time through the exciter. This is derived from the sum of static-, dynamic-, offset- and processing delay.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.20ColumnexcStatusAmplifierControlread-onlycurrentAmplifier control status
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.30ColumnexcStatusReqDataRateHPread-onlycurrentRequired data rate on HP input with respect to the current TPS settings.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.31ColumnexcStatusReqDataRateLPread-onlycurrentRequired data rate on LP input with respect to the current TPS settings.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.20.1.40ColumnexcStatusFailDelayread-onlycurrentShows whether the fail delay time is qualified.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21TableexciterPrecorrectionTablenot-accessiblecurrentExciter status values.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1RowexciterPrecorrectionEntrynot-accessiblecurrentA row (an entry) for one exciter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.3ColumnexcPrecExcIdxnot-accessiblecurrentThe dedicated exciter (A/B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.4ColumnexcPrecLinCorrectionread-writecurrentSwitches on/turns off the linear precorrector.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.5ColumnexcPrecLinAutomaticADEread-writecurrentEnables /disables the automatic precorrector. To get the ADE in work linear precorrection has to be switched on.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.6ColumnexcPrecLinMaxAmplitudeRippleread-writecurrentSets te maximum ripple for automatic amplitude correction (0.0 ... 2.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.7ColumnexcPrecLinMaxGroupDelayRippleread-writecurrentSets the maximum ripple for automatic group delay correction.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.8ColumnexcPrecLinAmplitudeRippleread-onlycurrentShows the current amplitude ripple.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.9ColumnexcPrecLinGroupDelayRippleread-onlycurrentShows the current group delay ripple.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.10ColumnexcPrecLinInputLevelread-onlycurrentShows the state of the feedback signal from the measurement point between output stage and antenna.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.11ColumnexcPrecLinAutomaticread-onlycurrentShows if the automatic precorrector works properly.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.12ColumnexcPrecNonlinCorrectionread-writecurrentSwitches on/turns off the nonlinear precorrector.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.13ColumnexcPrecNonlinAutomaticADEread-writecurrentEnables /disables the automatic precorrector. To get the ADE in work nonlinear precorrection has to be switched on.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.14ColumnexcPrecNonlinThresholdShouldersread-writecurrentThe target shoulder distance for ADE (0.0 ... 40.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.15ColumnexcPrecNonlinShoulderLeftread-onlycurrentDisplays the current measurement for the left handed shoulder distance.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.16ColumnexcPrecNonlinShoulderRightread-onlycurrentDisplays the current measurement of the right handed shoulder.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.17ColumnexcPrecNonlinInputLevelread-onlycurrentShows the state of the feedback signal from the measurement point between output stage and antenna.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.18ColumnexcPrecNonlinAutomaticread-onlycurrentShows if the automatic precorrector works properly.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.100ColumnexcPrecUserStateread-onlycurrentstatus of the user precorrection settings
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.101ColumnexcPrecFactoryStateread-onlycurrentstatus of the factory precorrection settings
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.102ColumnexcPrecRestoreCurrentSettingsread-writecurrentrestores current factory precorrection setting
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.21.1.103ColumnexcPrecRestoreAllSettingsread-writecurrentrestores all factory precorrection settings
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30TableconfigurationTablenot-accessiblecurrentTable for Type Configuration parameters.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1RowconfigurationEntrynot-accessiblecurrentAn entry for the Type Configuration parameters.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.3ColumnconfigTvStandardIdxnot-accessiblecurrentThe index for the TV standard.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.5ColumnconfigTvStandardNameread-onlycurrentThe name of the TV standard as a text.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.6ColumnconfigRxFrequencyread-writecurrentThe input frequency for input 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.7ColumnconfigFrequencyread-writecurrentThe output frequency for input 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.8ColumnconfigPowerread-writecurrentThe output power (0.0 ... 2500.0) for input 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.30.1.9ColumnconfigInputSourceread-writecurrentThe source for input 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31TabletimeSchedulerTablenot-accessiblecurrentTable for Time Scheduler parameters.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1RowtimeSchedulerEntrynot-accessiblecurrentAn entry in the table for the Time Scheduler parameters. A row in this table is created by setting the value of schedulerRowStatus to 'createAndGo' or 'createA…
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.3ColumnschedulerDateTimeIdxnot-accessiblecurrentThe DateAndTime index. Note: Deci-seconds different from 0 and UTC values are ignored. The index is implemented as a Fixed length string of 8 components. The l…
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.5ColumnschedulerRowStatusread-createcurrentThis object is used to create and delete rows in the timeSchedulerTable.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.6ColumnschedulerEventread-createcurrentThe event type.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.7ColumnschedulerDateTimeread-onlycurrentThe start date and the time of a daily or one-time event.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.31.1.8ColumnschedulerTvStandardread-createcurrentThe TV standard.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32Tableconfiguration2Tablenot-accessiblecurrentTable for Type Configuration parameters of input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1Rowconfiguration2Entrynot-accessiblecurrentAn entry for the Type Configuration parameters of input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.5Columnconfig2TvStandardNameread-onlycurrentThe name of the TV standard as a text.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.6Columnconfig2RxFrequencyread-writecurrentThe input frequency for input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.7Columnconfig2Frequencyread-writecurrentThe output frequency for input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.8Columnconfig2Powerread-writecurrentThe output power (0.0 ... 2500.0) for input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.32.1.9Columnconfig2InputSourceread-writecurrentThe source for input 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100TableproductInfoTablenot-accessiblecurrentThe table for product typeplates.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1RowproductInfoEntrynot-accessiblecurrentA row (an entry) for one typeplate.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.1ColumnprodInfoModuleIdxnot-accessiblecurrentThe module index.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.2ColumnprodInfoDeviceIdxnot-accessiblecurrentThe dedicated device (A/B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.3ColumnprodInfoRackIdxnot-accessiblecurrentThe rack number (1..10).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.4ColumnprodInfoAmpIdxnot-accessiblecurrentAmplifier Index
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.5ColumnprodInfoModuleNameread-onlycurrentThe name of the module as a text.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.6ColumnprodInfoSerialNumberread-onlycurrentThe serial number of the subdevice.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.7ColumnprodInfoIdentNumberSWread-onlycurrentThe Rohde&Schwarz identification number of the software, for example 2094.2090.02.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.8ColumnprodInfoVersionNumberSWread-onlycurrentThe Rohde&Schwarz revision number of the software, for example 1.2.1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.9ColumnprodInfoIdentNumberHWread-onlycurrentThe Rohde&Schwarz identification number of the hardware, for example 2095.8007.02 (NetCCU).
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.10ColumnprodInfoVersionNumberHWread-onlycurrentThe Rohde&Schwarz revision number (product index) of the hardware, for example 03.03.
1.3.6.1.4.1.2566.127.1.2.167.4.1.3.100.1.11ColumnproductInfoProductDateHWread-onlycurrentThe Rohde&Schwarz production date of the hardware,
1.3.6.1.4.1.2566.127.1.2.167.4.1.4Nodelogbook
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.1ScalarnetCCUNumberOfEntriesread-onlycurrentThe number of entries in logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.2ScalarnetCCULogbookClearread-writecurrentClear the logbook. idle(1) clear(2) A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3TablenetCCULogbookTablenot-accessiblecurrentNetCCU logbook table.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1RownetCCULogbookEntrynot-accessiblecurrentThis is a entry in the logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.1ColumnnetCCULogbookEntryIdxnot-accessiblecurrentThis is an increasing number from 1 to maximum. It is used as an index column for SNMP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.2ColumnnetCCULogbookEntryNbrread-onlycurrentThis is the number of the logbook entry. It is an decreasing number from maximum down to 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.3ColumnnetCCULogbookTyperead-onlycurrentCan either be Fault, Warning or State.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.4ColumnnetCCULogbookSloperead-onlycurrentEither set (event raises) or reset (event disappears)
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.5ColumnnetCCULogbookMessageread-onlycurrentSee RS-XX8000-COMMON-MIB - TextualConvention - LogbookEntryMessagesNetCCU for details.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.3.1.6ColumnnetCCULogbookDateTimeread-onlycurrentnetCCULogbookDateTime
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.4ScalarexciterANumberOfEntriesread-onlycurrentThe number of entries in logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.5ScalarexciterALogbookClearread-writecurrentClear the logbook. idle(1) clear(2) A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6TableexciterALogbookTablenot-accessiblecurrentExciterA logbook table.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1RowexciterALogbookEntrynot-accessiblecurrentThis is a entry in the logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.1ColumnexcALogbookEntryIdxnot-accessiblecurrentThis is an increasing number from 1 to maximum. It is used as an index column for SNMP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.2ColumnexcALogbookEntryNbrread-onlycurrentThis is the number of the logbook entry. It is an decreasing number from maximum down to 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.3ColumnexcALogbookTyperead-onlycurrentCan either be Fault, Warning or State.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.4ColumnexcALogbookSloperead-onlycurrentEither set (event raises) or reset (event disappears)
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.5ColumnexcALogbookMessageread-onlycurrentSee RS-XX8000-COMMON-MIB - TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.6.1.6ColumnexcALogbookDateTimeread-onlycurrentThe time of the logbook entry.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.7ScalaroutputstageANumberOfEntriesread-onlycurrentThe number of entries in logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.8ScalaroutputstageALogbookClearread-writecurrentClear the logbook. idle(1) clear(2) A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9TableoutputstageALogbookTablenot-accessiblecurrentOutputstageA logbook table.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1RowoutputstageALogbookEntrynot-accessiblecurrentThis is a entry in the logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.1ColumnostALogbookEntryIdxnot-accessiblecurrentThis is an increasing number from 1 to maximum. It is used as an index column for SNMP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.2ColumnostALogbookEntryNbrread-onlycurrentThis is the number of the logbook entry. It is an decreasing number from maximum down to 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.3ColumnostALogbookTyperead-onlycurrentCan either be Fault, Warning or State.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.4ColumnostALogbookSloperead-onlycurrentEither set (event raises) or reset (event disappears)
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.5ColumnostALogbookMessageread-onlycurrentSee RS-XX8000-COMMON-MIB - TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.9.1.6ColumnostALogbookDateTimeread-onlycurrentThe time of the logbook entry.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.10ScalarexciterBNumberOfEntriesread-onlycurrentThe number of entries in logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.11ScalarexciterBLogbookClearread-writecurrentClear the logbook. idle(1) clear(2) A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12TableexciterBLogbookTablenot-accessiblecurrentExciterB logbook table.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1RowexciterBLogbookEntrynot-accessiblecurrentThis is a entry in the logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.1ColumnexcBLogbookEntryIdxnot-accessiblecurrentThis is an increasing number from 1 to maximum. It is used as an index column for SNMP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.2ColumnexcBLogbookEntryNbrread-onlycurrentThis is the number of the logbook entry. It is an decreasing number from maximum down to 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.3ColumnexcBLogbookTyperead-onlycurrentCan either be Fault, Warning or State.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.4ColumnexcBLogbookSloperead-onlycurrentEither set (event raises) or reset (event disappears)
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.5ColumnexcBLogbookMessageread-onlycurrentSee RS-XX8000-COMMON-MIB - TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.12.1.6ColumnexcBLogbookDateTimeread-onlycurrentThe time of the logbook entry.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.13ScalaroutputstageBNumberOfEntriesread-onlycurrentThe number of entries in logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.14ScalaroutputstageBLogbookClearread-writecurrentClear the logbook. idle(1) clear(2) A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15TableoutputstageBLogbookTablenot-accessiblecurrentOutputstageB logbook table.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1RowoutputstageBLogbookEntrynot-accessiblecurrentThis is a entry in the logbook.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.1ColumnostBLogbookEntryIdxnot-accessiblecurrentThis is an increasing number from 1 to 128. It is used as an index column for SNMP.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.2ColumnostBLogbookEntryNbrread-onlycurrentThis is the number of the logbook entry. It is an decreasing number from max 128 down to 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.3ColumnostBLogbookTyperead-onlycurrentCan either be Fault, Warning or State.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.4ColumnostBLogbookSloperead-onlycurrentEither set (event raises) or reset (event disappears)
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.5ColumnostBLogbookMessageread-onlycurrentSee RS-XX8000-COMMON-MIB - TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.1.4.15.1.6ColumnostBLogbookDateTimeread-onlycurrentThe time of the logbook entry.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5TablerfProbesTablenot-accessiblecurrentThis table contains all commands for the RF probes.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1RowrfProbesEntrynot-accessiblecurrentAn entry for a designated transmitter and device.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.1ColumnrfProbesNetCCURfProbe1read-onlycurrentCurrent voltage on RF Probe 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.2ColumnrfProbesNetCCURfProbe2read-onlycurrentCurrent voltage on RF Probe 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.3ColumnrfProbesAntFwdNominalread-writecurrentThis sets the nominal value [W] of the transmitter (to antenna).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.4ColumnrfProbesAntFwdWarningLimitread-writecurrentThis sets the warning limit for the transmitters RF control (to antenna).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.5ColumnrfProbesAntFwdFailLimitread-writecurrentThis sets the fault limit for the transmitters RF control (to antenna).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.6ColumnrfProbesAntFwdDelayTimeRfFailread-writecurrentThis sets the delay time for the RF Fail control (to antenna).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.7ColumnrfProbesAntFwdSetOffsetread-writecurrentThis triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.8ColumnrfProbesAntFwdSetGainread-writecurrentThis triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.9ColumnrfProbesAntReflWarningLimitread-writecurrentThis sets the warning limit for the transmitters reflection control (to antenna).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.10ColumnrfProbesAntReflSetOffsetread-writecurrentThis triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.11ColumnrfProbesAntReflSetGainread-writecurrentThis triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.12ColumnrfProbesDLFwdNominalread-writecurrentThis sets the nominal value [W] of the transmitter (to dummyload).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.13ColumnrfProbesDLFwdWarningLimitread-writecurrentThis sets the warning limit for the transmitters RF control (to dummyload).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.14ColumnrfProbesDLFwdFailLimitread-writecurrentThis sets the fault limit for the transmitters RF control (to dummyload).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.15ColumnrfProbesDLFwdDelayTimeRfFailread-writecurrentThis sets the delay time for the RF Fail control (to dummyload).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.16ColumnrfProbesDLFwdSetOffsetread-writecurrentThis triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.17ColumnrfProbesDLFwdSetGainread-writecurrentThis triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.18ColumnrfProbesDLReflWarningLimitread-writecurrentThis sets the warning limit for the transmitters reflection control (to dummyload).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.19ColumnrfProbesDLReflSetOffsetread-writecurrentThis triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.20ColumnrfProbesDLReflSetGainread-writecurrentThis triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.21ColumnrfProbesOstIdxnot-accessiblecurrentThe dedicated outputstage (A/B).
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.22ColumnrfProbesOstFwdNominalread-writecurrentThis sets the nominal value [W] of the outputstage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.23ColumnrfProbesOstFwdWarningLimitread-writecurrentThis sets the warning limit for the outputstage RF control.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.24ColumnrfProbesOstFwdFailLimitread-writecurrentThis sets the fault limit for the outputstage RF control.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.25ColumnrfProbesOstFwdDelayTimeRfFailread-writecurrentThis sets the delay time for the outputstage RF Fail control.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.26ColumnrfProbesOstFwdSetOffsetread-writecurrentThis triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.27ColumnrfProbesOstFwdSetGainread-writecurrentThis triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.28ColumnrfProbesOstReflWarningLimitread-writecurrentThis sets the warning limit for the outputstage reflection control.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.29ColumnrfProbesOstReflSetOffsetread-writecurrentThis triggers Set Offset.
1.3.6.1.4.1.2566.127.1.2.167.4.1.5.1.30ColumnrfProbesOstReflSetGainread-writecurrentThis triggers Set Gain.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6TablerackTablenot-accessiblecurrentThis table contains important commands for the racks.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1RowrackEntrynot-accessiblecurrentAn entry for a designated rack or rack's rf probe.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.2ColumnostDeviceIdxnot-accessiblecurrentThe index to address outputstageA and outputstageB.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.3ColumnrackIdxnot-accessiblecurrentThe index to address the racks.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.4ColumnrackRfProbeIdxnot-accessiblecurrentThe index to address forward and reflected RF probes. For not RF probe parameters this index is always 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.6ColumnamplifiersPerRackread-onlycurrentThe number of amplifiers of a rack.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.7ColumnrackRfEventSignallingread-writecurrentThis configures whether to signal rf events or not.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.8ColumnrackReferenceVoltageread-writecurrentThis parameter controls the reference voltage (31.0 ... 100.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.9ColumnamplifiersPowerSupplyread-writecurrentThis parameter controls the power supplies of the amplifier within the rack (31.0 ... 100.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.10ColumnrackGeneralPurposeInputread-writecurrentSetting of the general purpose input behaviour.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.20ColumnrackOnOffread-writecurrentThis switches the rack on/off.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.50ColumnrfProbePresentread-onlycurrentIf the RF probe of this rack is present.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.51ColumnrfProbeConfigurationLabelread-writeobsoleteName for the measured signal on RF Probe.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.52ColumnrfProbeConfigurationNominalValueread-writecurrentThe nominal value of the measured signal.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.55ColumnrfProbeThresholdRfFailLimitread-writecurrentFault limit for the RF control (-20.0 ... 0.0).
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.56ColumnrfProbeThresholdTimeoutRfFailCtrread-writecurrentTimeout for RF Fail Control.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.57ColumnrfProbeThresholdWarningLimitread-writecurrentWarning limit for the RF control (-20.0 ... 0.0). For reflected probes: Warning limit for the reflection control. This limit is added to the fault limit to gen…
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.60ColumnrfProbeCalibrationGainread-onlycurrentMeasured value of gain calibration.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.61ColumnrfProbeCalibrationOffsetread-onlycurrentMeasured value of offset calibration.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.62ColumnrfProbeCalibrationSetGainread-writecurrentSets the gain calibration.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.63ColumnrfProbeCalibrationSetOffsetread-writecurrentSets the offset calibration.
1.3.6.1.4.1.2566.127.1.2.167.4.1.6.1.65ColumnrfProbeMeasuredValueread-onlycurrentMeasured forward/reflected power of antenna signal.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7Tablesx801AmplifierTablenot-accessiblecurrentAmplifier status values for SX801 amplifiers.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1Rowsx801AmplifierEntrynot-accessiblecurrentA row (an entry) for one amplifier.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.1Columnsx801AmpIdxnot-accessiblecurrentThe amplifier index.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.2Columnsx801AmpRfOutread-onlycurrentShows if the amplifier generates an RF or not. off(1): The amplifier output is switched off e.g. because the amplifier gets no input signal or the transmitter …
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.3Columnsx801AmpRfInread-onlycurrentDisplays the state of the amplifier input. off(1): no input signal detected warning(2): the level of the input signal is too low or too high. ok(3): input sign…
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.4Columnsx801AmpReflectionread-onlycurrentA reflection on RF output of this Amplifier module has been detected. This leads to a reduction of output power of the amplifier.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.5Columnsx801AmpOnread-onlycurrentShows if the amplifier has been switched on by the control unit.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.6Columnsx801AmpACread-onlycurrentShows the state of primary voltage of the power supply.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.7Columnsx801AmpCommunicationread-onlycurrentDisplays if the CAN communication between amplifier and Sx801 is working or not.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.8Columnsx801AmpTransistorread-onlycurrentA transistor fail is displayed here. For further information please see the amplifiers service menue.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.9Columnsx801AmpDriverread-onlycurrentShows a failure if one of the internal driver transistors does not work properly. For further information please see the amplifiers service menue.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.10Columnsx801AmpTemperatureread-onlycurrentShows a fault if the temperature of amplifier module is too high.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.11Columnsx801AmpBlowerread-onlycurrentDisplays the state of the internal blowers.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.12Columnsx801AmpRegulationread-onlycurrentShows a fault if the amplifier is not able to control its output power.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.13Columnsx801AmpUpdateread-onlycurrentFirmware update is in progress. This will be started automatically during a software update procedure of the transmitter.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.14Columnsx801Supply1Temperatureread-onlycurrentShows a fault if the temperature of power supply one is too high.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.15Columnsx801Supply2Temperatureread-onlycurrentShows a fault if the temperature of power supply two is too high.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.16Columnsx801SupplyRTemperatureread-onlycurrentShows a fault if the temperature of the reserve power supply is too high.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.17Columnsx801Supply1DCread-onlycurrentShows a fault if the output voltage of power supply one is not ok.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.18Columnsx801Supply2DCread-onlycurrentShows a fault if the output voltage of power supply two is not ok.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.19Columnsx801SupplyRDCread-onlycurrentShows a fault if the output voltage of the reserve power supply is not ok.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.50Columnsx801AmpValueI1read-onlycurrentThe internal current from transistor pair 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.51Columnsx801AmpValueI2read-onlycurrentThe internal current from transistor pair 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.52Columnsx801AmpValueI3read-onlycurrentThe internal current from transistor pair 3.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.53Columnsx801AmpValueI4read-onlycurrentThe internal current from transistor pair 4.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.54Columnsx801AmpValueIPreread-onlycurrentThe internal current from preamplifier.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.55Columnsx801AmpValueIDrv1read-onlycurrentThe internal current from driver transistor pair 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.56Columnsx801AmpValueIDrv2read-onlycurrentThe internal current from driver transistor pair 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.57Columnsx801AmpValuePowerOutread-onlycurrentThe base value in Volt to calculate the output power of this amplifier module.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.58Columnsx801AmpValueReflectionread-onlycurrentThe base value in Volt for detection of reflections.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.59Columnsx801AmpValueVRefread-onlycurrentThe internal reference voltage to set the output power.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.60Columnsx801AmpValueVRegread-onlycurrentThe internal value for output power regulation.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.61Columnsx801AmpValueTemperatureread-onlycurrentThe internal temperature of Amplifier. In case of L-band amplifier, the shown temperature is valid only, if the amplifier is switched on.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.62Columnsx801AmpValueMonAttread-onlycurrentThe attenuation of monitoring output on the front of the amplifier module (Amp RF Mon).
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.63Columnsx801AmpValueVAux1read-onlycurrentThe voltage power detector 1.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.64Columnsx801AmpValueVAux2read-onlycurrentThe voltage power detector 2.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.65Columnsx801Supply1ValuePwrread-onlycurrentThe power supply one control voltage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.66Columnsx801Supply2ValuePwrread-onlycurrentThe power supply two control voltage.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.67Columnsx801Supply1ValueDcread-onlycurrentThe internal supply voltage of transistor path two. In systems with two power supplies this value is equal to the output voltage of supply one.
1.3.6.1.4.1.2566.127.1.2.167.4.1.7.1.68Columnsx801Supply2ValueDcread-onlycurrentThe internal supply voltage of transistor path two. In systems with two power supplies this value is equal to the output voltage of supply two.
1.3.6.1.4.1.2566.127.1.2.167.4.3NodersXx8000DvbTxEvents
1.3.6.1.4.1.2566.127.1.2.167.4.3.2NodeeventTx
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0IdentityeventsTxV2currentCompatibility to SMIv1.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.1NotificationtxSummaryFaultcurrentTransmitter Summary Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.2NotificationtxSummaryWarningcurrentTransmitter Summary Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.3NotificationtxLocalcurrentTransmitter Local/Remote
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.4NotificationtxRfOncurrentTransmitter RF On/Off
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.5NotificationtxRfOkcurrentTransmitter RF Ok / Not OK
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.6NotificationtxParamSetSubDeviceDiffersobsoleteParameterset of subdevice is different. The currently loaded parameterset is inconsistent because a subdevice (e.g. an exciter) has a different configuration t…
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.7NotificationtxParamSetValuesChangedcurrentValue Of Current Parameterset Changed. The currently loaded parameterset is inconsistent because there were changes happening since the load/save of it. To cor…
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.8NotificationtxRfLoopProgramcurrentNetCCU Loop Program
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.9NotificationtxRfLoopReservecurrentNetCCU Loop Reserve
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.10NotificationtxRfWarningcurrentNetCCU RF Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.11NotificationtxReflectionWarningcurrentNetCCU Reflection Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.12NotificationtxNetCCUFanFaultcurrentNetCCU Fan Fault. This is valid, if Fan Control is switched on (see menu NetCCU Setup - Common).
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.13NotificationtxNetCCUPowerSupplycurrentNetCCU Power Supply
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.14NotificationtxRfFailcurrentNetCCU RF Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.15NotificationtxReflectionFaultcurrentNetCCU Reflection Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.16NotificationtxNetCCUBoardTemperatureFaultdeprecatedNetCCU Board Temperature Fault deprecated: this information is now handled as a warning (txNetCCUBoardTemperatureWarning)
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.17NotificationtxNetCCUNoConnectionToExcAcurrentNetCCU Connection To ExciterA Faulty
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.18NotificationtxNetCCUNoConnectionToOstAcurrentNetCCU Connection To OutputstageA Faulty
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.19NotificationtxNetCCUNoConnectionToExcBcurrentNetCCU Connection To ExciterB Faulty
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.20NotificationtxNetCCUNoConnectionToOstBcurrentNetCCU Connection To OutputstageB Faulty
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.21NotificationtxAutomaticExcReadycurrentExciter Automatic Ready.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.22NotificationtxAutomaticExcChangedcurrentExciter Automatic Changed.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.23NotificationtxAutomaticExcFaultcurrentExciter Automatic Fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.24NotificationtxAutomaticOstReadycurrentOutputstage Automatic Ready. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.25NotificationtxAutomaticOstChangedcurrentOutputstage Automatic Changed. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.26NotificationtxAutomaticOstFaultcurrentOutputstage Automatic Fault. This paramter is only available for systems with an automatic output switch.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.27NotificationtxNetCCUBoardTemperatureWarningcurrentNetCCU Board Temperature Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.30NotificationtxInternalPowerSupplyWarningcurrentNetCCU internal Power Supply warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.31NotificationtxExternalPowerSupplyWarningcurrentNetCCU external (additional) Power Supply warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.35NotificationtxModeSwitchOverStartedcurrentSwitch over of TX mode started.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.36NotificationtxModeSwitchOverEndedcurrentSwitch over of TX mode ended.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.37NotificationtxModeInconsistentcurrentAn inconsistency in configuration of TX mode was detected. The CCU and exiter configurations are incompatible.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.38NotificationtxModeSwitchOverFailedcurrentSwitch over of TX mode failed. Please check whether the configurations of CCU and exciter are correct.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.100NotificationtxExcSummaryFaultcurrentExciter Summary Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.101NotificationtxExcSummaryWarningcurrentExciter Summary Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.102NotificationtxExcLocalcurrentExciter Local/Remote
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.104NotificationtxExcRfOkcurrentExciter RF Ok
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.105NotificationtxExcInputNoConnectHP1currentExciter Input HP1 has no connected input signal
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.106NotificationtxExcInputNoConnectLP1currentExciter Input LP1 has no connected input signal
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.107NotificationtxExcInputNoConnectHP2currentExciter Input HP2 has no connected input signal
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.108NotificationtxExcInputNoConnectLP2currentExciter Input LP2 has no connected input signal
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.109NotificationtxExcInputActiveHP1currentExciter Input HP1 is active
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.110NotificationtxExcInputActiveLP1currentExciter Input LP1 is active
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.111NotificationtxExcInputActiveHP2currentExciter Input HP2 is active
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.112NotificationtxExcInputActiveLP2currentExciter Input LP2 is active
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.113NotificationtxExcOncurrentExciter On
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.114NotificationtxExcRfOncurrentExciter RF On
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.115NotificationtxExcNoInputcurrentExciter has no valid input signal.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.116NotificationtxExcRfLoopcurrentExciter RF loop
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.117NotificationtxExcRfFailcurrentExciter RF Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.118NotificationtxExcSelfTestcurrentExciter hardware self test
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.119NotificationtxExcOutputOpencurrentExciter output open
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.120NotificationtxExcBoardTemperatureWarningcurrentExciter Board Temperature
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.121NotificationtxExcFanWarningcurrentExciter has one faulty fan
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.122NotificationtxExcFanFaultcurrentBoth exciter fans are faulty.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.123NotificationtxExcFifoWarningcurrentExciter Fifo
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.124NotificationtxExcTestSignalcurrentExciter Testsignal Active
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.125NotificationtxExcSFNDelaycurrentExciter SFN Delay Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.126NotificationtxExcWrongDataratecurrentExciter Wrong Datarate
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.127NotificationtxExcMutecurrentExciter Mute
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.128NotificationtxExcPPSFailcurrentExciter PPS Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.129NotificationtxExcReferenceFailcurrentExciter Reference Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.130NotificationtxExcMIPFailcurrentExciter MIP Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.131NotificationtxExcInputAutomaticSwitchReadycurrentInput automatic is ready.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.132NotificationtxExcInputAutomaticChangedOvercurrentInput automatic changed over.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.133NotificationtxExcInputReseveMissingcurrentMissing input, or automatic switching enabled with only one input present. Disable automatic switching or press reset fault to remove this warning. Monitoring …
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.200NotificationtxOstSummaryFaultcurrentOutputstage Summary Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.201NotificationtxOstSummaryWarningcurrentOutputstage Summary Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.202NotificationtxOstRfOncurrentOutputstage RF On
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.203NotificationtxOstRfOkcurrentOutputstage RF Ok
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.204NotificationtxOstNoInputcurrentOutputstage no input signal
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.205NotificationtxOstRfWarningcurrentOutputstage RF Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.206NotificationtxOstReflectionWarningcurrentOutputstage Reflection Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.207NotificationtxOstRackWarningcurrentOutputstage Rack Warning. At least one rack has an error pending.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.208NotificationtxOstCoolingWarningcurrentOutputstage Cooling Warning
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.209NotificationtxOstRfFailcurrentOutputstage RF Fail
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.210NotificationtxOstReflectionFaultcurrentOutputstage Reflection Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.211NotificationtxOstACFaultcurrentOutputstage AC Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.212NotificationtxOstCoolingFaultcurrentOutputstage Cooling Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.213NotificationtxOstCommFaultcurrentOutputstage Communication Fault
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.300NotificationtxRackSumFaultcurrentSummary Fault at a designated rack. This event automatically leads to txOstRackWarning.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.301NotificationtxRackSumWarningcurrentSummary Warning at a designated rack.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.302NotificationtxRackOncurrentThe designated racks operation mode is on.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.303NotificationtxRackGpiWarningcurrentA warning on the general purpose input occurred. This depends on the current configuration of the GPI. (See:Rack Setup/Rack Controller)
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.304NotificationtxRackFan1FaultcurrentThe designated rack signals a fault of fan 1.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.305NotificationtxRackFan2FaultcurrentThe designated rack signals a fault of fan 2.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.306NotificationtxRackCoolingSumWarningcurrentThe designated rack signals a summary cooling warning.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.307NotificationtxRackAmplifierSumFaultcurrentThe designated rack signals at least one faulty amplifier.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.308NotificationtxRackNoLinkcurrentNo communication to the designated rack.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.309NotificationtxRackGpiFaultcurrentA fault on the general purpose input occurred. This depends on the current configuration of the GPI. (See:Rack Setup/Rack Controller)
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.310NotificationtxRackTemperatureFaultcurrentThe designated rack signals a temperature fault - temperature too high.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.311NotificationtxRackACFaultcurrentThe designated rack signals an AC (phase) fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.312NotificationtxRackCoolingSumFaultcurrentThe designated rack signals a summary cooling fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.313NotificationtxRackTempFaultAbs1currentThe designated rack signals a temperature fault of absorber 1.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.314NotificationtxRackTempFaultAbs2currentThe designated rack signals a temperature fault of absorber 2.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.315NotificationtxRackDCFaultcurrentThe designated rack signals a DC fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.318NotificationtxRackRfOncurrentRF power is on.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.319NotificationtxRackRfOkcurrentRF power is ok.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.320NotificationtxRackRfWarningcurrentRF power decreased the warning threshold.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.321NotificationtxRackRfFaultcurrentRF output power decreased the fault threshold.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.322NotificationtxRackReflectionWarningcurrentThe reflected power increased the warning threshold
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.323NotificationtxRackReflectionFaultcurrentThe reflected power increased the fault threshold.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.330NotificationtxRackProbeNotCalibratedcurrentAt least one probe is not calibrated.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.331NotificationtxRackTemperatureWarningcurrentRack temperature exceeded the warning threshold.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.335NotificationtxRackOvervoltProtectWarningcurrentOvervoltage protection is out of order.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.400NotificationtxAmpSumFaultcurrentThe designated amplifier signals summary fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.401NotificationtxAmpSumWarningcurrentThe designated amplifier signals summary warning.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.402NotificationtxAmpPowerOncurrentThe designated amplifiers power is on.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.403NotificationtxAmpDCOkcurrentThe designated amplifiers DC is ok.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.404NotificationtxAmpACOkcurrentThe designated amplifiers AC is ok.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.405NotificationtxAmpRfInFailcurrentThe designated amplifier signals RF input fail.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.406NotificationtxAmpRfFailcurrentThe designated amplifier signals RF fail.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.407NotificationtxAmpReflectionFaultcurrentThe designated amplifier signals a reflection fault.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.408NotificationtxAmpTemperatureFaultcurrentThe designated amplifier signals a temperature fault - temperature is too high.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.0.409NotificationtxAmpTransistorFaultcurrentThe designated amplifier signals at least one faulty transistor.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1TableeventsTxTablenot-accessiblecurrentThis table contains necessary information for handling alarms. For each alarm you have the following information: - name (get), - mask to enable/disable sendin…
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1RoweventsTxEntrynot-accessiblecurrentAn event entry always consists of its indexes (used for addressing within redundancy systems) and 3 values: - name: an enumerated list of all possible notifica…
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.1ColumneventTxABIdxnot-accessiblecurrentThe value for the module A (exciterA, outputstageA) or B (exciterB, outputstageB) for alarms. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.2ColumneventTxRackIdxnot-accessiblecurrentThe number of the designated rack. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.3ColumneventTxAmpIdxnot-accessiblecurrentThe number of the designated amplifier. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.4ColumneventTxNameIdxnot-accessiblecurrentThe event number as integer. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.5ColumneventTxNameread-onlycurrentThe event number as integer and the value as readable text. The enumeration correlates with the notifications under eventsTxV2.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.6ColumneventTxMaskread-writecurrentSee TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.7ColumneventTxPriorityread-writecurrentSee TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.3.2.1.1.8ColumneventTxEventread-onlycurrentSee TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.167.4.5NodersXx8000DvbTxConf
1.3.6.1.4.1.2566.127.1.2.167.4.5.1NodersXx8000DvbTxGroups
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.1GroupgroupEventscurrentThis group includes all OIDs for event handling.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.2GroupgroupTxCommoncurrentGroup for common transmitter objects
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.3GroupgroupEventsTxCommoncurrentThis group includes all alarm OIDs that are common for all reserve concepts.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.4GroupgroupDualDrivecurrentThis group includes additional objects for reserve concepts DualDrive (NetCCU + 2 * exciter + outputstage) and Active/Passive Reserve (NetCCU + 2 * exciter + 2…
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.5GroupgroupEventsDualDrivecurrentThis group includes additional events for reserve concepts DualDrive (NetCCU + 2 * exciter + outputstage) and Active/Passive Reserve (NetCCU + 2 * exciter + 2 …
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.6GroupgroupPowerReservecurrentThis group includes additional objects for reserve concept Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) For more details, refer to manual.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.7GroupgroupEventsPowerReservecurrentThis group includes additional events for reserve concept Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) For more details, refer to manual.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.8GroupgroupCommonMPcurrentadditional objects for medium/high power
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.9GroupgroupEventsCommonMPcurrentadditional events for medium/high power
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.10GroupgroupCommonNetCCUcurrentadditional objects for transmitters with NetCCU
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.11GroupgroupEventsCommonNetCCUcurrentadditional events for transmitters with NetCCU
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.12GroupgroupOstBLogbookcurrentobjects of logbook for output stage B
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.14GroupgroupSumProbecurrentobjects that are available only when sum probe exists
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.18GroupgroupProductInfocurrentThis group includes all OIDs for device product information.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.19GroupgroupAmpMeasureValuescurrentThis group includes all OIDs amplifier measure values. Practically, these information are not important to customers, they are needed in manufactory.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.20GroupgroupEventsAmplifiercurrentevents from the amplifier (medium/high power only)
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.21GroupgroupRfProbescurrentThis group includes all OIDs regarding RF Probes.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.22GroupgroupDummyLoadRFcurrentThis group includes all object types regarding probes from dummy load. The object types in this group are defined only when a dummy load measure point exists. …
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.23GroupgroupExcCommoncurrentGroup for common exciter objects
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.24GroupgroupExcAdditionalSx800currentAdditional exciter objects for the Sx800
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.25GroupgroupExcAdditionalSLxcurrentAdditional exciter objects for the SLx and the Sx801
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.26GroupgroupEventsExcitercurrentevents from the exciter
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.27GroupgroupExciterStatuscurrentGroup for exciterStatusTable.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.28GroupgroupExciterPrecorrectioncurrentGroup for exciterPrecorrectionTable.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.29GroupgroupSLxcurrentobject types that are relevant for SLx devices only
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.30GroupgroupObjectsACUcurrentobjects from ACU
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.31GroupgroupIndependentRackscurrentobject types that are relevant for NX variants with independent racks only
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.32GroupgroupObjectsREcurrentobject types for the re-equip kit
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.34GroupgroupEventsControlExcitercurrentadditional events in case Sx801 is control exciter
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.35GroupgroupEventsAdditionalPowerSupplycurrentEvents that are available only when additionalPowerSupply is true.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.36GroupgroupObjsAdditionalPowerSupplycurrentObjects that are available only when additionalPowerSupply is true.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.37GroupgroupObjectsControlExcitercurrentadditional objects in case Sx801 is control exciter
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.38GroupgroupObjectsSingleEndedcurrentGroup for objects in case of SingleTx or DualDrive.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.39GroupgroupObjectsSx801AmplifiercurrentObjects for Sx801/SA801 amplifier status.
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.99GroupgroupObsoletedobsoleteobsoleted or deprecated objects
1.3.6.1.4.1.2566.127.1.2.167.4.5.1.100GroupgroupEventsObsoletedobsoleteobsoleted or deprecated events
1.3.6.1.4.1.2566.127.1.2.167.4.5.3NodersXx8000DvbTxCompl
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.1CompliancersXx8000DVBSingleTxMPnot-accessiblecurrentReserve concept SingleTransmitter for Medium Power.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.2CompliancersXx8000DVBDualDriveMPnot-accessiblecurrentReserve concept DualDrive for Medium Power.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.3CompliancersXx8000DVBPowerReserveMPnot-accessiblecurrentReserve concept Active/Passive Reserve for Medium Power.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.5CompliancersXx8000DVBSingleTxLPcurrentReserve concept Low Power SingleTransmitter with NetCCU, meaning there is a NetCCU and a LowPower exciter with one or more (to the exciter) connected amplifier…
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.6CompliancersXx8000DVBDualDriveLPcurrentReserve concept DualDrive for Low Power.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.7CompliancersXx8000DVBPowerReserveLPcurrentReserve concept Active/Passive Reserve for Low Power.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.9CompliancersXx8000DVBSingleTxLPNoNetCCUcurrentReserve concept Low Power SingleTransmitter without NetCCU, meaning there is only a LowPower exciter with one or more (to the exciter) connected amplifiers.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.10CompliancersXx8000DVBSLxcurrentSLx device
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.11CompliancersXx8000DVBExciterOnlycurrentDVB Exciter of 8000 series in a 7000 environment or Program Exciter in a Sx801 Backup Exciter environment.
1.3.6.1.4.1.2566.127.1.2.167.4.5.3.12CompliancersXx8000DVBSx801ControlExcitercurrentSx801 as control exciter
1.3.6.1.4.1.2566.149.1.163.3IdentityrsXx8000DvbTxMibModuleThis MIB defines transmitting systems from Rohde & Schwarz. Use this MIB if your system meets the following requirements: - series XX8000 (NetCCU800), - DVB, -…