MIB Viewer

axisImaGroupTestProcStatus

OBJECT-TYPE
1.3.6.1.4.1.351.110.5.2.1.1.4.1.1.22
Access
read-write
Status
mandatory
Sub-identifiers
0
This object is used to enable or disable the Test Pattern Proceudre,and to note whether at least one link failed the test. The test is started by setting operating(2) status.If any link should fail the test ,the IMA will set the status to linkfail(3).The linkfail(3) state will persist until either the disabled(1) state is set or until no instance of imaLinkTestProcStatus has the value linkfail(3). Only the values disabled(1) and operating(2) may be written. Writing the opersting(2) value will not cause clearing of the linkfail(3) state.
INTEGER { disabled(1), operating(2), linkfail(3) }