OBJECT-TYPE
1.3.6.1.4.1.1754.1.6.1.1.1.3
Access
read-only
Status
mandatory
Sub-identifiers
0
This 2 byte bit-mapped register defines the asynchronous events that can occur on the chassis. When this object is read the 'Chassis Event' bit in the devEventStatus object will be reset to zero. Values: 0 = no fault, 1 = fault. Register Definition: BYTE 0 Bit 0: Fan 1 fault (left-most fan, from back of chassis) Bit 1: Fan 2 fault Bit 2: Fan 3 fault Bit 3: Fan 4 fault (right-most fan, from back of chassis) Bit 4: Power Supply 1 fault Bit 5: Power Supply 2 fault (if high availability unit) Bit 6: Power Supply 3 fault (if high availability unit) Bit 7: Reserved BYTE 1 Bit 0: Temperature fault Bits 1-3: Reserved: Bit 4: POST fault Bits 5-7: Reserved: