MIB Viewer

cdx6500frdtepConnectionType

OBJECT-TYPE
1.3.6.1.4.1.449.2.1.2.1.1.5.1.2
Access
read-write
Status
mandatory
Sub-identifiers
0
Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required dtr - dedicated, require the data terminal ready signal (DTR) simpb - simple, no control signals required for data transmission and reception. By default output leads will be low. nc - Skipped during configuration.
INTEGER { simp (1), dtr (2), simpb (21), nc (100) }