MIB Viewer

checkResultInterval

OBJECT-TYPE
1.3.6.1.2.1.7777.1.3.1.5
Access
read-create
Status
current
Source
CHECK-MIB
Sub-identifiers
0
The interval between two performances of the check defined in this row. When this object is set to a value greater than 0, then the check is performed regularly with the number of centi-seconds indicated by this object between two performances. When this object is successfully set to a value greater than 0, then the check is not performed immediately. The first check is performed after the number of centi-seconds specified by the new value of the object. If a performance is scheduled to start before the previous one has been completed, then the previous check will be completed and the scheduled check will be skipped. If the number of this object is 0, then the check is performed only on request when the value of the object checkResultSeverity is retrieved by a manager. A set operation on this object may lead to an inconsistentValue error in two cases: - if the vale passed is greater than 0 but less than the value of checkCapabMinCheckInterval; - if the value passed is greater than 0 and the check defined in this row includes rules with delta operations.
TimeInterval