MIB Viewer

cienaCesOamLoopbackCommand

OBJECT-TYPE
1.3.6.1.4.1.1271.2.3.5.1.1.6.1.2
Access
read-only
Status
current
Sub-identifiers
0
This attribute initiates or terminates remote loopback with an OAM peer. Value startRemoteLoopback(2) of this attribute indicates the local OAM client to send a loopback OAMPDU to the OAM peer with the loopback enable flags set. Value stopRemoteLoopback(3) of this attribute indicates the local OAM client to send a loopback OAMPDU to the OAM peer with the loopback enable flags cleared. Value noLoopback(1) to this attribute has no effect. The attribute always returns noLoopback on a read. To determine the loopback status, use the attribute cienaCesOamLoopbackStatus.
INTEGER { noLoopback(1), startRemoteLoopback(2), stopRemoteLoopback(3) }