MIB Viewer

cmMaintCmdRecurrence

OBJECT-TYPE
1.3.6.1.4.1.1996.20.16.1.1.4
Access
read-write
Status
mandatory
Sub-identifiers
0
For automatic commands (such as 'configBackup' and 'statsAuto'), this is the number of hours between each execution of the command. For the 'configBackup' command, a value of 0 indicates to do the backup once. The command will be executed at the given StartTime. If Recurrence is zero and StartTime is zero (or in the past), the backup will be executed immediately. For 'statsAuto', the number of hours is limited to 6. This ensures that the system provides consistent data with no gaps in the uploaded files regardless of recent changes to the sampling interval. Also, the ReportingPeriod will be made to match the Recurrence value. For 'configRestore', the value of this object is ignored. For 'bulkCPEDownload', the recurrence must be 0. Default: 0
INTEGER