MIB Viewer

decAtmCardStatus

OBJECT-TYPE
1.3.6.1.4.1.36.2.18.30.1.2.4.1.2
Access
read-write
Status
mandatory
Sub-identifiers
0
The status of the card. If the value is read as 'notPresent(1)', then the entire entry should be considered invalid. Writing a value of 'powerDown(2)' will cause the switch to power down the card. Writing a value of 'powerUp(3)' will cause the switch to power up the card. Writing a value of 'powerDownThenUp(4)' will cause the switch to power cycle the line card. Attempts to set any other values will result in a badValue error. Cards which are fundamental to switch operation cannot be powered up or down through this object. Unpopulated slots will either be 'notPresent(1)' or missing from the table, and cannot be powered up or down.
INTEGER { notPresent(1), powerDown(2), powerUp(3), powerDownThenUp(4), fault(5), revisionMismatch(6), selfTestInProgress(7) }