MIB Viewer

decAtmLoadAdminStatus

OBJECT-TYPE
1.3.6.1.4.1.36.2.18.30.1.12.1.1
Access
read-write
Status
mandatory
Sub-identifiers
0
This object is used to control the program load process of a device. When read, the value other(1) is returned. When set to start-reboot (2) the device reloads the stored firmware. When set to start-read-BootP(3) the device clears the address and host configuration file location in NVRAM and initiates a BootP read operation to find and read a new program image. When set to start-read-TFTP(4) the device saves the local host address and host configuration file location in NVRAM and initiates a TFTP read operation to read a new program image. A device always resets during a successful load attempt. It may not reset upon unsuccessful completion of the load attempt.
INTEGER { other(1), start-reboot (2), start-read-BootP (3), start-read-TFTP (4) }