MIB Viewer

dot3PhyMode

OBJECT-TYPE
1.3.6.1.4.1.193.72.800.10.11.1.1.2
Access
read-write
Status
current
Sub-identifiers
0
This describes the duplex mode and speed for each port. This is an extension to RFC2665 where the duplex status and interface speed can be modifed for each port. For ports 1-8, allowed values are autoNeg, halfDuplex10, halfDuplex100, fullDuplex10, fullDuplex100. Setting is not allowed for port 9. It can be only read. For port 9, the value retuned indicates the type of SFP module inserted. If no SFP module is inserted, invalid(0) is returned. If 100Mbps SFP module is inserted, fullDuplex100(5) is returned. If 1000Mbs SFP module is inserted, fullDuplex1000(6) is returned.
INTEGER { invalid(0), autoNeg(1), halfDuplex10(2), halfDuplex100(3), fullDuplex10(4), fullDuplex100(5), fullDuplex1000(6)}