MIB Viewer

dsx1ExtCfgLineBuildOut

OBJECT-TYPE
1.3.6.1.4.1.495.2.1.6.53.10.1.12
Access
read-write
Status
mandatory
Sub-identifiers
0
Specifies the attenuation or Line Build Out to be used on the transmitter side of the line. Options: For T1 1: 0 to 133 feet / 0 dB 2: 133 to 266 feet 3: 266 to 399 feet 4: 399 to 533 feet 5: 533 to 655 feet 6: -7.5 dB 7: -15 dB 8: -22.5 dB For E1 1: 75 Ohm (coax. cable) 2: 120 Ohm (RJ45 shilded twisted pair) 3: 75 Ohm ( with protection resistor) 4: 120 Ohm ( with protection resistor) 5: 75 Ohm (with high return loss 1:1.15) 6: 120 Ohm (with high return loss 1:1.36) 7: 75 Ohm (with high return loss 1:1.36) 8: N/A Default Value: 1 Configuration Changed: administrative
INTEGER (1..8)