MIB Viewer

equipConfigChange

OBJECT-TYPE
1.3.6.1.4.1.3373.1103.1.14
Access
read-write
Status
current
Sub-identifiers
0
Set by the NE when the equipment configuration is changed by the local or Remote LOM. The octet string is a bit stream of flags; a set bit is a change on a specific item. We had: Byte 0.7: change in configuration for equipment group Byte 0.6: change in configuration for userInput group Byte 0.5: change in configuration for userOutput group Byte 0.4: change in configuration for alarmLog group ...... Byte 3.7: change in a severity for equipment group Byte 3.6: change in a severity for userInput group Byte 3.5: change in a severity for userOutput group Byte 3.4: change in a severity for alarmLog group CEM can reset the change condition writing one to desired bit flag ......
OCTET STRING (SIZE(6))