MIB Viewer

erptrDprLinkToggle

OBJECT-TYPE
1.3.6.1.4.1.36.2.18.11.5.1.1.3.3.1.1.4
Access
read-write
Status
mandatory
Sub-identifiers
0
If erptrDprLinkType equals redundantMaster, setting this object to toggle(2) causes a redundant link specified by this table entry to undergo a state change. That is, the repeater forces the previously active link segment into the standby state and the previously inactive link segment into the active state. If erptrDprLinkType equals redundantResponder, setting this object to toggle(2) has no effect. Setting this object to noToggle(1) has no effect. The agent always returns a value of noToggle(1) when this object is read.
INTEGER { noToggle(1), toggle(2) }