MIB Viewer

gx2Dm2000HoldTimeData

OBJECT-TYPE
1.3.6.1.4.1.1166.6.1.2.34.6.5.3
Access
read-write
Status
mandatory
Sub-identifiers
0
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
INTEGER