MIB Viewer

lbOptSMTHoldState

OBJECT-TYPE
1.3.6.1.4.1.43.7.2.1.1.1.4
Access
read-only
Status
mandatory
Sub-identifiers
0
This variable indicates the current state of the Hold function. The value 'not-holding' is the default and initial value. The value must be set to 'not-holding' as part of Active_Actions and when the conditions causing 'holding-prm' or 'holding-sec' are no longer true. The value 'holding-prm' must be set when the condition (notTR_Flag & not RE_Flag & (PC_LS=QLS | LEM_Fail | TNE>NS_Max | (not LS_Flag & TPC > T_Out))) is satisfied in state PC8:ACTIVE for the A Port. The value 'holding-sec' must be set when the condition (notTR_Flag & not RE_Flag & (PC_LS=QLS | LEM_Fail | TNE>NS_Max | (not LS_Flag & TPC > T_Out))) is satisfied in state PC8:ACTIVE for the B Port.
INTEGER { not-implemented(1), not-holding(2), holding-prm(3), holding-sec(4) }