MIB Viewer

lpDS1LineLength

OBJECT-TYPE
1.3.6.1.4.1.562.2.4.1.12.7.10.1.5
Access
read-write
Status
mandatory
Sub-identifiers
0
This attribute defines the line length (in feet) for equalization calculations for the DS1 line. The value ranges between 0-655. For 8pDS1Atm cards the actual value used for equalization is rounded up to the nearest 110 feet; for all other card types the actual value used is rounded to the nearest 50 feet.