MIB Viewer

ntcHWAvailabilityStatus

OBJECT-TYPE
1.3.6.1.4.1.94.1.16.7.1.1.1.1.3
Access
read-only
Status
current
Sub-identifiers
0
Provides more specific information on the state of the unit in this conceptual row. The status column has eleven defined values: inCharge = the unit is fully operational and ready to perform its desired tasks; applicationStarting = the application software is starting up; applicationShutdown = the application software is shutting down; platformStarting = Basic platform software is starting up; resetting = the disk files are closed and hardware reset is forced; separated = Only basic OS software is running. The unit can start application software on request; unconfigured = The administrative state of the unit is 'missing', disk files are closed and only basic OS software is running. The unit refuses to start application software; testing = Selftests can be performed, only basic OS are running; standby = The unit is redundant and is fully operational but not in charge of operations. It is ready to move to 'inCharge' state when necessary; dormant = All connections are physically inactive to enable removal of the unit without electric disturbance in the backplane. Only watchdog software is running for a short duration of time; unavailable = The unit is not physically present or cannot be contacted.
INTEGER { inCharge(1), applicationStarting(2), applicationShutdown(3), platformStarting(4), resetting(5), separated(6), unconfigured(7), testing(8), standby(9), dormant(10), unavailable(11) }