MIB Viewer

oc3APSPairStatus

OBJECT-TYPE
1.3.6.1.4.1.1751.2.18.2.16.1.1.12
Access
read-only
Status
current
Source
ACMIB
Sub-identifiers
0
noFailure : The protection line is not in use. modeMismatch : one end is configured unidirectional and the other is bidirectional (both the ends should be configured in the same mode). Also when one end is configured for 1:1 architechture and the other end indicates it is configured for 1:n architechture.(Bidirectional mode only) swByteFailure: protection switching byte failure - defect declared when invalid / persistantly unacceptable codes are received in the K1 byte. failure declared if defect persists for an extended period. Invalid code is when the incoming K1 byte contains an unused code or a code irrelevant for the specific switching operation.(Only in bi-directional mode) chMismatch : channel mismatch is declared when the channel numbers in the transmitted K1 byte and the received K2 byte do not match for 50 ms.Channel mismatch is monitored only in bidirectional mode.
INTEGER { noFailure(1), modeMismatch(2), swByteFailure(3), chMismatch(4) }