outputSupervisionBehavior

OBJECT-TYPE
1.3.6.1.4.1.19947.1.3.2.1.15
Access
read-write
Status
current
Sub-identifiers
0
A bit field packed into an integer which define the behavior of the output channel / power supply after failures. For each supervision value, a two-bit field exists. The enumeration of this value (..L+..H*2) is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate. iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. The position of the bit fields in the integer value are: Bit 0, 1: outputFailureMinSenseVoltage Bit 2, 3: outputFailureMaxSenseVoltage Bit 4, 5: outputFailureMaxTerminalVoltage Bit 6, 7: outputFailureMaxCurrent Bit 8, 9: outputFailureMaxTemperature Bit 10, 11: outputFailureMaxPower Bit 12, 13: outputFailureInhibit Bit 14, 15: outputFailureTimeout
Integer32 (0..65535)