MIB Viewer

ps32PowerSupplyOperStatus

OBJECT-TYPE
1.3.6.1.4.1.10.2.1.4.2.2.1.4
Access
read-only
Status
mandatory
Sub-identifiers
0
Actual status of the power supply: - unknown(1) - status not known. - empty(2) - no power supply installed in slot - disabled(3) - unable to supply power - control register has requested this supply be disabled. - bad(4) - unable to supply power due to failure - warning(5) - supplying power but an output or sensor is bad or warning - standby(6) - believed usable but not supplying power - engaged(7) - supplying power - redundant(8) - supplying power but not needed It is an implementation specific matter whether the agent keeps entries with status unknown(1) or empty(2) in the table.
INTEGER { unknown(1), empty(2), disabled(3), bad(4), warning(5), standby(6), engaged(7), redundant(8) }