riLdcHfExtState

OBJECT-TYPE
1.3.6.1.4.1.28.10.14.12
Access
read-write
Status
mandatory
Sub-identifiers
0
The current state of external hot failover detection. External hot failover detection is only available for the bus on which the master INX-NMM's NIC is configured. Setting this variable to enabled(1) invokes external hot failover detection/monitoring. In addition to the status returned by the riLdcHfIntState object, the following two failures descriptions are returned if an enable(1) fails with a General Error. dis-zero-p1-addr(8) is returned when the Ping 1 address is set to 0.0.0.0. See the Ext Failover Detection/Ping 1 variable. dis-wrong-ext-bus(9) is returned when the master NIC is on Bus B and the primary or backup configuration for Bus B is invalid. See the Bus B Primary Backbone Slot #, Bus B Backup Backbone Slot #, Bus B Primary Backbone Media, and Bus B Backup Backbone Media variables.
INTEGER { enabled(1), disabled(2), dis-no-A-config(3), dis-no-B-config(4), dis-A-B-conflict(5), dis-zero-frequency(6), dis-no-backbone(7), dis-zero-p1-addr(8), dis-wrong-ext-bus(9) }