MIB Viewer

riTsPortModemControl

OBJECT-TYPE
1.3.6.1.4.1.28.4.28.1.14
Access
read-write
Status
mandatory
Sub-identifiers
0
The type of modem control, if any, on this port. This setting determines the use of the modem control RS-232 signals. Enter a value that matches the setting of the attached device. o none(1) means that no modem control signals are in use. This is the default. o dce(2) means that the INX-NTS port will act as a DCE device in monitoring the modem control signals. This is the appropriate setting if you are attaching a DTE device (for example, a terminal) that uses these signals to the INX-NTS port. (Ports are always wired as DCE, regardless of modem settings.) o dte(3) means that the INX-NTS port will act as a DTE (Data Terminal Equipment) device in monitoring the modem control signals. Use this setting when attaching a DCE (Data Communication Equipment) device (such as a modem) to the INX-NTS port. Note: Setting Modem Control to DTE can require the use of a cabling adapter at the device.
INTEGER { none(1), dce(2), dte(3) }