MIB Viewer

rpcFwFlash

OBJECT-TYPE
1.3.6.1.4.1.16177.1.400.1.3.2.1
Access
read-write
Status
current
Sub-identifiers
0
Start download/flash of a new firmware. To flash a new firmware to the device, define a valid URL accessible by the device. Change the firmware URL parameter `setFwFileUrl` in the settings section, if needed. * Writing **flash(2)** to this parameter will download and validate the new firmware file. if the downloaded file is recognized as a valid firmware for this device, it will be flashed to the file system of the device. * Writing **flashWithConfig(3)** to this parameter will download the firmware and the custom config defined with setCfgFileUrl and validate the new firmware file. If the download is recognized as a valid firmware for this device, it will be written to the file system of the device. The supplied custom config will be applied after the upgrade. Reading this parameter will return the status of the firmware flash process. A value of **flashError(-2)** indicates that the flash process failed during writing. A return value of **downloadError(-1)** indicates the occurrence of an error during download or validation of the firmware/config. A value of **flash(2)** indicates that the device is currently writing the firmware to the file system. Applies to AP and STA.
INTEGER { flashError(-2), downloadError(-1), nop(0), download(1), flash(2), flashWithConfig(3) }