MIB Viewer

s5TrPortAFD

OBJECT-TYPE
1.3.6.1.4.1.45.1.6.7.1.1.1.14
Access
read-write
Status
mandatory
Sub-identifiers
0
This object reflects the capability for a port to disable AFD, Automatic Frequency Detection. The following values can be read: notCapableOfAFDDisable(1)... The port is incapable of AFD disable. capableAndAFDEnabled(2)... The port is capable of AFD disable and the current AFD is enabled. capableAndAFDDisabled(3)... The port is capable of AFD disable and the current AFD is disabled. The following values can be written: capableAndAFDEnabled(2)... Enable the AFD. capableAndAFDDisabled(3)... Disable the AFD. Note: The values capableAndAFDEnabled(2) and capableAndAFDDisabled(3) are only valid for writing if the port has the capability of AFD disable.
INTEGER { notCapableOfAFDDisable(1), capableAndAFDEnabled(2), capableAndAFDDisabled(3) }