MIB Viewer

snetSwitchStatus

OBJECT-TYPE
1.3.6.1.4.1.169.8.3.2.5.1.1.8
Access
read-only
Status
mandatory
Sub-identifiers
0
The Overall Status for the Switch. This is determined by a combination of port status values and configuration values. If a port is configured, it should detect Link Alive. If the port is not in LinkAlive state, the switch status will be degraded. If all configured ports are in LinkAlive state, the switch status will be ok. Hardware, Firmware and Fan status are also used to determine switch status as described below. This represents the overall condition of the specified switch. Other(1): Switch not installed or status unknown OK(2): All ports, Hardware, Firmware and Fan status are OK. Degraded(3): One or more ports are down. Hardware or Firmware status show an error condition. Failed(4): All ports are Failed, switch is not reachable, Fan status is failed.
INTEGER{ other(1), ok(2), degraded(3), failed(4) }