MIB Viewer

swSysSystemLogSeverityThreshold

OBJECT-TYPE
1.3.6.1.4.1.114.1.4.1.27.3
Access
read-write
Status
mandatory
Sub-identifiers
0
This object determines the miminum serverety level of events recorded in the system log. For example, if the swSysSysteLogSeverityThreshold is set to errors(3) than only events which have serverity levels of error(3) or higher will be recorded.
INTEGER { informational(1), warning(2), error(3), fatal(4) }