MIB Viewer

temperatureCloseToTooHigh

NOTIFICATION-TYPE
1.3.6.1.4.1.193.72.300.1.2.0.23
Status
deprecated
Sub-identifiers
0
Indicates the temperature is close to the too high value. This alarm should be considered as a warning alarm that is received a while before the high temperature is reached. Corrective Actions: - Check that the fans for the device are working properly. - Check that the environment temperature is acceptable. - For the IPDSLAM it might help to remove some subscribers from the line. Deprecated from: EDA 1.1 R2A Parameters 1: Managed object class IPDSLAM 2: Managed object ID [MAC] 3: Sequence number [Alarm sequence number] 4: Perceived severity Major 5: Event time [Timestamp is retrieved from a SNTP server] 6: Event type Equipment 7: Probable cause TemperatureUnacceptable 8: Temperature value [Value in degree Celsius] Ceasing OID: 1.3.6.1.4.1.193.72.300.1.2.0.24 # tempCloseToTooHighCeasing Ceasing OID: 1.3.6.1.4.1.193.72.300.1.2.0.8 # IP DSLAM RestartAlarm