MIB Viewer

temperatureTooHigh

NOTIFICATION-TYPE
1.3.6.1.4.1.193.72.300.1.2.0.1
Status
deprecated
Sub-identifiers
0
The temperature is too high and has increased above a fixed threshold value. The high temperature value is probably caused by fan failure or high environment temperature. For the IP DSLAM the lines are stopped in order to reduce the power consumption and avoid damage to the device. Corrective Actions: - Check that the fans for the device is working properly. - Check that the environment temperature is acceptable. - For the IPDSLAM it might help to remove some subscibers from the lines. Deprecated from: EDA 1.1 R2A Parameters 1: Managed object class IPDSLAM 2: Managed object ID [MAC] 3: Sequence number [Alarm sequence number] 4: Perceived severity Critical 5: Event time [Timestamp is retrieved from a SNTP server] 6: Event type Equipment 7: Probable cause temperatureUnacceptable 8: Temp control state [Low, Normal, High or TooHigh] 9: Temperature value [Value in degree Celsius] Ceasing OID: 1.3.6.1.4.1.193.72.300.1.2.0.2 # temperatureTooHighCeasing Ceasing OID: 1.3.6.1.4.1.193.72.300.1.2.0.8 # IP DLSAM RestartAlarm