This object defines the configuration of the system-wide alarm cut-off (ACO) button. It could be UMC_Mode, Standard_Mode, or Extended_Mode ACO operation. In the UMC_Mode, one push of the ACO button results in the cut-off of the current alarms and the clearing of the Plug-and-play current alarm conditions. The Plug-and-play alarms are Missing Card Alarm, Loss of Composite Clock Alarm, Loss of A/B Power Lead Alarm, Unexpected RSU Registration Alarm. In Standard_Mode mode, the ACO button operates as a traditional ACO and only cuts off audible alarms. The Plug-and-play alarms can only be cleared via the Craft User interface or the restoration of the event that caused the alarm. In the Extended_Mode ACO the ACO button has two time thresholds, a short one, and a long one. A short depression of the ACO button results in alarm cut-off, but it does not clear the plug and play alarms. A long depression of the ACO button results in the alarm cut off and the clearing of plug and play alarms. The acceptable values for this object and their corresponding meanings are: Integer Value Meaning 1 UMC Mode 2 Standard Mode 3 Extended ACO Mode