MIB Viewer

wdmCtrlGroupChannelStartupCommand

OBJECT-TYPE
1.3.6.1.4.1.8708.2.4.2.9.1.1.23
Access
read-only
Status
current
Sub-identifiers
0
Initiates a safe startup sequence for all the channels of selected group. If the administrative status of the channel is 'down' or the channel is not detected by the monitor unit, the system attempts to detect the channel as follows: 1) The attenuation is set to its maximum value. 2) The attenuation is decreased until the channel is detected by the monitor. When the channel is detected, regulation of the channel is started, ignoring the regulation range. If the channel cannot be detected, channelStatus is set to notFound. If regulation fails, channelStatus is set to 'error' and an alarm is raised. When the startup sequence is finished, the administrative status of the channel is set to 'up'. If a regulation is ongoing when the startup procedure is initiated, the channel is put on a waiting queue until the ongoing regulation is finished. The startup queue has a limited length. If the queue is filled up with waiting channels, further startup commands will be blocked until all the queued channels have been started.
CommandString